Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 231.1
edited by Theodore Xu
on 2023/04/23 15:42
on 2023/04/23 15:42
Change comment:
There is no comment for this version
To version 253.1
edited by Theodore Xu
on 2023/08/22 15:32
on 2023/08/22 15:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 18 added, 0 removed)
- ControlStarCommunicate.png
- ControlStarModbus.png
- ControlStarSystemBlock.png
- Emerson.png
- HollySysRS232.png
- Hollysys LM Modbus RTU.gif
- Hollysys485-2.png
- Hollysys485box.png
- V-NET_Client_TNBuqy7T5r.png
- plc 软件.png
- wire.png
- 企业微信截图_16889606174191.png
- 盒子创建英威腾.png
- 英威腾下载.png
- 英威腾创建1.png
- 英威腾创建2.png
- 英威腾创建3.png
- 英威腾软件.png
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,11 @@ 1 +{{info}} 2 +✎Note: Communication Connection Description 3 + 4 +* Modbus TCP:Maximum 16 devices 5 +* Modbus RTU:Maximum 32 devices 6 +* Ethernet protocol:Maximum 16 devices 7 +{{/info}} 8 + 1 1 = Create communication with WECON PLC = 2 2 3 3 == **LX3V Serial Protocol** == ... ... @@ -520,7 +520,7 @@ 520 520 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 521 521 522 522 523 -= **Micro850_FreeTag Protocol(new)** = 531 +== **Micro850_FreeTag Protocol(new)** == 524 524 525 525 This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 526 526 ... ... @@ -582,7 +582,7 @@ 582 582 (% style="text-align:center" %) 583 583 [[image:V-NET_Client_communication.png]] 584 584 585 -Export variables from PLC, select CSV file, comma delimited. After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]iconaddlabel.593 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %) 586 586 587 587 (% style="text-align:center" %) 588 588 [[image:export1.png]] ... ... @@ -590,8 +590,10 @@ 590 590 (% style="text-align:center" %) 591 591 [[image:CCW.Shell_E5Cwj4tUL3.png]] 592 592 601 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label. 602 + 593 593 (% style="text-align:center" %) 594 -[[image:V-NET_Client_ iKKKhcgxm1.png]]604 +[[image:V-NET_Client_TNBuqy7T5r.png]] 595 595 596 596 **3)Engineering production** 597 597 ... ... @@ -661,6 +661,142 @@ 661 661 **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 662 662 {{/info}} 663 663 674 += Create communication with EMERSON PLC = 675 + 676 += **RTU Slave Protocol** = 677 + 678 +Supported series: EC10 series 679 + 680 +**1)V-BOX setting** 681 + 682 +|**Items**|**Settings**|**Note** 683 +|Protocol|Emerson 984 RTU Slave MODBUS| 684 +|Connection|RS485| 685 +|Baud rate|19200| 686 +|Data bit|8| 687 +|Parity|EVEN| 688 +|Stop bit|1| 689 +|Device station No.|1|Need to be same as the PLC setting 690 + 691 +(% class="wikigeneratedid" %) 692 +**2)PLC Setting** 693 + 694 +(% class="wikigeneratedid" %) 695 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 696 + 697 +(% style="text-align:center" %) 698 +[[image:ControlStarSystemBlock.png]] 699 + 700 +(% style="text-align:center" %) 701 +[[image:ControlStarCommunicate.png]] 702 + 703 +(% style="text-align:center" %) 704 +[[image:ControlStarModbus.png]] 705 + 706 +(% class="wikigeneratedid" %) 707 +**3)Address List** 708 + 709 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 710 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 711 +|X|XOOO|0~~377| 712 +|M0|M0DDDD|0~~2047| 713 +|M1|M1DDDDD|2048~~10239| 714 +|SM0|SM0DDD|0~~255| 715 +|SM1|SM1DDD|256~~511| 716 +|S0|S0DDDD|0~~1023| 717 +|S1|S1DDDD|1024~~4095| 718 +|T0|T0DDD|0~~255| 719 +|T1|T1DDD|256~~511| 720 +|C0|C0DDD|0~~255| 721 +|C1|C1DDD|256~~306| 722 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 723 +|Z|ZDD|0~~15| 724 +|TW0|TW0DDD|0~~255| 725 +|TW1|TW1DDD|256~~511| 726 +|SD0|SD0DDD|0~~255| 727 +|SD1|SD1DDD|256~~511| 728 +|CW|CWDDD|0~~306| 729 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 730 +|CW1|CW1DDDDD|256~~99999| 731 + 732 +**4) Cable Wiring** 733 + 734 +(% style="text-align:center" %) 735 +[[image:Emerson.png]] 736 + 737 += Create communication with HollySys PLC = 738 + 739 +== **LK Modbus RTU** == 740 + 741 +Supported Series: HollySys LK series PLC 742 + 743 +**1)V-BOX setting** 744 + 745 +|**Items**|**Settings**|**Note** 746 +|Protocol|HollySys LK Modbus RTU| 747 +|Connection|RS485| 748 +|Baud rate|38400| 749 +|Data bit|8| 750 +|Parity|None| 751 +|Stop bit|1| 752 +|Device station No.|1| 753 + 754 +**2)Address List** 755 + 756 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 757 +|Bit|QX|QXDDDDD.dd|0~~65535.15| 758 +|Bit|IX|IXDDDDD.dd|0~~65535.15| 759 +|Bit|MX|MXDDDDD.dd|0~~65535.15| 760 +|Word|QW|QWDDDDD|0~~99999| 761 +|Word|IW|IWDDDDD|0~~99999| 762 +|Word|MW|MWDDDDD|0~~99999| 763 +|Word|MD|MDDDDDD|0~~99999| 764 + 765 +**3)Cable Wiring** 766 + 767 +(% style="text-align:center" %) 768 +[[image:Hollysys485-2.png]] 769 + 770 +== **LM Modbus RTU** == 771 + 772 +(% class="wikigeneratedid" %) 773 +Supported Series: HollySys LM3109/LM3107 PLC 774 + 775 +(% class="wikigeneratedid" %) 776 +**1)V-BOX setting** 777 + 778 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note** 779 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %) 780 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %) 781 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %) 782 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %) 783 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %) 784 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 785 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 786 + 787 +**2)Address List** 788 + 789 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 790 +|Bit|QX|QXDDDDD.o|0~~99999.7| 791 +|Bit|IX|IXDDDDD.o|0~~99999.7| 792 +|Bit|MX|MXDDDDD.o|0~~99999.7| 793 +|Word|QW|QWDDDDD|0~~99999| 794 +|Word|IW|IWDDDDD|0~~99999| 795 +|Word|MW|MWDDDDD|0~~99999| 796 +|Word|MD|MDDDDDD|0~~99999| 797 + 798 +**Cable Wiring** 799 + 800 +RS232 801 + 802 +(% style="text-align:center" %) 803 +[[image:HollySysRS232.png]] 804 + 805 +RS485 806 + 807 +(% style="text-align:center" %) 808 +[[image:Hollysys LM Modbus RTU.gif]] 809 + 664 664 = Create communication with **Siemens PLC** = 665 665 666 666 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -2069,6 +2069,74 @@ 2069 2069 2070 2070 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2071 2071 2218 += Create communication with INVT PLC = 2219 + 2220 +**1)V-BOX setting** 2221 + 2222 +|**Item**|**Settings**|**Note** 2223 +|Protocol|INVT_IVC2L| 2224 +|Connection|RS232| 2225 +|Baud rate|19200| 2226 +|Data bit|8| 2227 +|Parity|EVEN| 2228 +|Stop bit|1| 2229 +|PLC station No.|1 2230 + 2231 +**2)Address List** 2232 + 2233 + 2234 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 2235 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377| 2236 +|Y|YOOO|0~~377| 2237 +|M|MDDDD|0~~1999| 2238 +|SM|SMDDD|0~~255| 2239 +|S|SDDD|0~~991| 2240 +|T|TDDD|0~~255| 2241 +|C|CDDD|0~~255| 2242 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999| 2243 +|SD|SDDDD|0~~255| 2244 +|Z|ZDD|0~~15| 2245 +|T|TDDD|0~~255| 2246 +|C|CDDD|0~~199| 2247 +|Double word|C|CDDD|200~~255| 2248 + 2249 +**3)Communication Settings** 2250 + 2251 +(% style="text-align:center" %) 2252 +[[image:盒子创建英威腾.png]] 2253 + 2254 +**4)PLC software** 2255 + 2256 +(% style="text-align:center" %) 2257 +[[image:英威腾软件.png]] 2258 + 2259 +**5)PLC setting ** 2260 + 2261 +Open the INVI plc software, create a new project or open a project that has already been created 2262 + 2263 +(% style="text-align:center" %) 2264 +[[image:英威腾创建1.png]] 2265 + 2266 +Configure serial port parameters. 2267 + 2268 +(% style="text-align:center" %) 2269 +[[image:英威腾创建2.png]] 2270 + 2271 +PC connect PLC 2272 + 2273 +(% style="text-align:center" %) 2274 +[[image:英威腾创建3.png]] 2275 + 2276 +Download 2277 + 2278 +(% style="text-align:center" %) 2279 +[[image:英威腾下载.png]] 2280 + 2281 +**6)Cable Wiring** 2282 + 2283 +(% style="text-align:center" %) 2284 +[[image:wire.png]] 2285 + 2072 2072 = Create communication with **Modbus ** = 2073 2073 2074 2074 == **MODBUS RTU Slave (All function)** ==
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- HollySysRS232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- Hollysys LM Modbus RTU.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.4 KB - Content
- V-NET_Client_TNBuqy7T5r.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- plc 软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.8 KB - Content
- wire.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content
- 企业微信截图_16889606174191.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.7 KB - Content
- 盒子创建英威腾.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.5 KB - Content
- 英威腾下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.0 KB - Content
- 英威腾创建1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- 英威腾创建2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.7 KB - Content
- 英威腾创建3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.6 KB - Content
- 英威腾软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.6 KB - Content