Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 232.1
edited by Theodore Xu
on 2023/04/23 15:46
on 2023/04/23 15:46
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Hunter - Content
-
... ... @@ -2,6 +2,8 @@ 2 2 3 3 == **LX3V Serial Protocol** == 4 4 5 +== **xcvxvxcv** == 6 + 5 5 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 7 **1)V-BOX setting** ... ... @@ -663,6 +663,102 @@ 663 663 **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 664 664 {{/info}} 665 665 668 += Create communication with EMERSON PLC = 669 + 670 +== **RTU Slave Protocol** == 671 + 672 +Supported series: EC10 series 673 + 674 +**1)V-BOX setting** 675 + 676 +|**Items**|**Settings**|**Note** 677 +|Protocol|Emerson 984 RTU Slave MODBUS| 678 +|Connection|RS485| 679 +|Baud rate|19200| 680 +|Data bit|8| 681 +|Parity|EVEN| 682 +|Stop bit|1| 683 +|Device station No.|1|Need to be same as the PLC setting 684 + 685 +(% class="wikigeneratedid" %) 686 +**2)PLC Setting** 687 + 688 +(% class="wikigeneratedid" %) 689 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 690 + 691 +(% style="text-align:center" %) 692 +[[image:ControlStarSystemBlock.png]] 693 + 694 +(% style="text-align:center" %) 695 +[[image:ControlStarCommunicate.png]] 696 + 697 +(% style="text-align:center" %) 698 +[[image:ControlStarModbus.png]] 699 + 700 +(% class="wikigeneratedid" %) 701 +**3)Address List** 702 + 703 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 704 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 705 +|X|XOOO|0~~377| 706 +|M0|M0DDDD|0~~2047| 707 +|M1|M1DDDDD|2048~~10239| 708 +|SM0|SM0DDD|0~~255| 709 +|SM1|SM1DDD|256~~511| 710 +|S0|S0DDDD|0~~1023| 711 +|S1|S1DDDD|1024~~4095| 712 +|T0|T0DDD|0~~255| 713 +|T1|T1DDD|256~~511| 714 +|C0|C0DDD|0~~255| 715 +|C1|C1DDD|256~~306| 716 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 717 +|Z|ZDD|0~~15| 718 +|TW0|TW0DDD|0~~255| 719 +|TW1|TW1DDD|256~~511| 720 +|SD0|SD0DDD|0~~255| 721 +|SD1|SD1DDD|256~~511| 722 +|CW|CWDDD|0~~306| 723 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 724 +|CW1|CW1DDDDD|256~~99999| 725 + 726 +**4) Cable Wiring** 727 + 728 +(% style="text-align:center" %) 729 +[[image:Emerson.png]] 730 + 731 += Create communication with HollySys PLC = 732 + 733 +== **LK Modbus RTU** == 734 + 735 +Supported Series: HollySys LK series PLC 736 + 737 +**1)V-BOX setting** 738 + 739 +|**Items**|**Settings**|**Note** 740 +|Protocol|HollySys LK Modbus RTU| 741 +|Connection|RS485| 742 +|Baud rate|38400| 743 +|Data bit|8| 744 +|Parity|None| 745 +|Stop bit|1| 746 +|Device station No.|1| 747 + 748 +**2)Address List** 749 + 750 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 751 +|Bit|QX|QXDDDDD.dd|0~~65535.15| 752 +|Bit|IX|IXDDDDD.dd|0~~65535.15| 753 +|Bit|MX|MXDDDDD.dd|0~~65535.15| 754 +|Word|QW|QWDDDDD|0~~99999| 755 +|Word|IW|IWDDDDD|0~~99999| 756 +|Word|MW|MWDDDDD|0~~99999| 757 +|Word|MD|MDDDDDD|0~~99999| 758 + 759 +**3)Cable Wiring** 760 + 761 +(% style="text-align:center" %) 762 +[[image:Hollysys485-2.png]] 763 + 666 666 = Create communication with **Siemens PLC** = 667 667 668 668 == **S7-200 Smart Ethernet Protocol** ==
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.4 KB - Content