Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 233.1
edited by Hunter
on 2023/05/06 14:29
Change comment: There is no comment for this version
To version 258.1
edited by Theodore Xu
on 2023/08/23 19:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -1,6 +1,6 @@
1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -277,7 +277,7 @@
277 277  (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 278  (% id="cke_bm_5621S" style="display:none" %)** **
279 279  
280 -== **MicroLogix Protocol** ==
280 +== **MicroLogix Serial** ==
281 281  
282 282  (% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -317,7 +317,7 @@
317 317  
318 318  [[image:image-20220824110724-1.png]]
319 319  
320 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
321 321  
322 322  (((
323 323  (((
... ... @@ -520,7 +520,7 @@
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 522  
523 -== **Micro850_FreeTag Protocol(new)** ==
523 +== **Micro850_FreeTag Ethernet(new)** ==
524 524  
525 525  This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 526  
... ... @@ -605,13 +605,13 @@
605 605  
606 606  )))
607 607  
608 -== **Ethernet DF1 Protocol** ==
608 +== **Ethernet DF1** ==
609 609  
610 610  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
611 611  
612 -= Create communication with **Crouzet PLC** =
612 += **Crouzet PLC** =
613 613  
614 -== **CROUZET M3 (FBD)** ==
614 +== **CROUZET M3 (FBD) Serial** ==
615 615  
616 616  Support Series: Crouzet Millenium 3 CD12/CB12
617 617  
... ... @@ -663,23 +663,150 @@
663 663  **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 664  {{/info}}
665 665  
666 -= Create communication with **EMERSON PLC** =
666 += EMERSON =
667 667  
668 -== **RTU Slave Protocol** ==
668 += **RTU Slave ** =
669 669  
670 -Supported Series: EC10 series
670 +Supported series: EC10 series
671 671  
672 672  **1)V-BOX setting**
673 673  
674 -= Create communication with **Siemens PLC** =
674 +|**Items**|**Settings**|**Note**
675 +|Protocol|Emerson 984 RTU Slave MODBUS|
676 +|Connection|RS485|
677 +|Baud rate|19200|
678 +|Data bit|8|
679 +|Parity|EVEN|
680 +|Stop bit|1|
681 +|Device station No.|1|Need to be same as the PLC setting
675 675  
676 -== **S7-200 Smart Ethernet Protocol** ==
683 +(% class="wikigeneratedid" %)
684 +**2)PLC Setting**
677 677  
678 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
686 +(% class="wikigeneratedid" %)
687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
679 679  
689 +(% style="text-align:center" %)
690 +[[image:ControlStarSystemBlock.png]]
680 680  
681 -== **S7-300 Ethernet Protocol** ==
692 +(% style="text-align:center" %)
693 +[[image:ControlStarCommunicate.png]]
682 682  
695 +(% style="text-align:center" %)
696 +[[image:ControlStarModbus.png]]
697 +
698 +(% class="wikigeneratedid" %)
699 +**3)Address List**
700 +
701 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 +|X|XOOO|0~~377|
704 +|M0|M0DDDD|0~~2047|
705 +|M1|M1DDDDD|2048~~10239|
706 +|SM0|SM0DDD|0~~255|
707 +|SM1|SM1DDD|256~~511|
708 +|S0|S0DDDD|0~~1023|
709 +|S1|S1DDDD|1024~~4095|
710 +|T0|T0DDD|0~~255|
711 +|T1|T1DDD|256~~511|
712 +|C0|C0DDD|0~~255|
713 +|C1|C1DDD|256~~306|
714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 +|Z|ZDD|0~~15|
716 +|TW0|TW0DDD|0~~255|
717 +|TW1|TW1DDD|256~~511|
718 +|SD0|SD0DDD|0~~255|
719 +|SD1|SD1DDD|256~~511|
720 +|CW|CWDDD|0~~306|
721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 +|CW1|CW1DDDDD|256~~99999|
723 +
724 +**4) Cable Wiring**
725 +
726 +(% style="text-align:center" %)
727 +[[image:Emerson.png]]
728 +
729 += HollySys PLC =
730 +
731 +== **LK Modbus RTU ** ==
732 +
733 +Supported Series: HollySys LK series PLC
734 +
735 +**1)V-BOX setting**
736 +
737 +|**Items**|**Settings**|**Note**
738 +|Protocol|HollySys LK Modbus RTU|
739 +|Connection|RS485|
740 +|Baud rate|38400|
741 +|Data bit|8|
742 +|Parity|None|
743 +|Stop bit|1|
744 +|Device station No.|1|
745 +
746 +**2)Address List**
747 +
748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
749 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
750 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
751 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
752 +|Word|QW|QWDDDDD|0~~99999|
753 +|Word|IW|IWDDDDD|0~~99999|
754 +|Word|MW|MWDDDDD|0~~99999|
755 +|Word|MD|MDDDDDD|0~~99999|
756 +
757 +**3)Cable Wiring**
758 +
759 +(% style="text-align:center" %)
760 +[[image:Hollysys485-2.png]]
761 +
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
801 +
802 += **Siemens ** =
803 +
804 +== **S7-200 Smart Ethernet ** ==
805 +
806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
807 +
808 +== **S7-300 Ethernet ** ==
809 +
683 683  Supported Series: Siemens S7-300 series PLC
684 684  
685 685  **1)V-BOX setting**
... ... @@ -736,11 +736,11 @@
736 736  )))
737 737  )))
738 738  
739 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
740 740  
741 741  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
742 742  
743 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
744 744  
745 745  Supported Series: Siemens S7-400, S7-1200 and S7-1500
746 746  
... ... @@ -854,7 +854,7 @@
854 854  
855 855  [[image:image-20220824162342-2.png]]
856 856  
857 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
858 858  
859 859  Supported Series: Siemens Logo 0BA0, 0BA1 series
860 860  
... ... @@ -945,9 +945,9 @@
945 945  ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
946 946  ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
947 947  
948 -= Create communication with **Mitsubishi PLC** =
1075 += **Mitsubishi ** =
949 949  
950 -== **FX1S,1N,2N Serial Protocol** ==
1077 +== **FX1S,1N,2N Serial ** ==
951 951  
952 952  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
953 953  
... ... @@ -994,7 +994,7 @@
994 994  [[image:image-20220825100845-4.png]]
995 995  
996 996  
997 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
998 998  
999 999  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
1000 1000  
... ... @@ -1041,7 +1041,7 @@
1041 1041  [[image:image-20220825100845-4.png]]
1042 1042  
1043 1043  
1044 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
1045 1045  
1046 1046  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
1047 1047  
... ... @@ -1136,7 +1136,7 @@
1136 1136  
1137 1137  [[image:image-20221119101946-2.png||height="395" width="695"]]
1138 1138  
1139 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
1140 1140  
1141 1141  Mitsubishi FX5U series PLC
1142 1142  
... ... @@ -1218,7 +1218,7 @@
1218 1218  
1219 1219  [[image:image-20220825105533-3.png]]
1220 1220  
1221 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
1222 1222  
1223 1223  Mitsubishi FX5U series PLC
1224 1224  
... ... @@ -1294,7 +1294,7 @@
1294 1294  
1295 1295  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1296 1296  
1297 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1298 1298  
1299 1299  Mitsubishi L02 series CPU built-in serial port.
1300 1300  
... ... @@ -1354,7 +1354,7 @@
1354 1354  
1355 1355  [[image:image-20220825160820-4.png]]
1356 1356  
1357 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1358 1358  
1359 1359  Mitsubishi L series CPU built-in Ethernet port.
1360 1360  
... ... @@ -1427,13 +1427,13 @@
1427 1427  
1428 1428  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1429 1429  
1430 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1431 1431  
1432 1432  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1433 1433  
1434 1434  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1435 1435  
1436 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1437 1437  
1438 1438  Mitsubishi QJ71E71 Ethernet communication module;
1439 1439  
... ... @@ -1508,9 +1508,9 @@
1508 1508  
1509 1509  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1510 1510  
1511 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1512 1512  
1513 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1514 1514  
1515 1515  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1516 1516  
... ... @@ -1575,7 +1575,7 @@
1575 1575  (% style="text-align:center" %)
1576 1576  [[image:DVPEthernetVNETPortocol.png]]
1577 1577  
1578 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1579 1579  
1580 1580  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1581 1581  
... ... @@ -1611,7 +1611,7 @@
1611 1611  (% style="text-align:center" %)
1612 1612  [[image:Delta DVP PROTOCOLSerial232.png]]
1613 1613  
1614 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1615 1615  
1616 1616  **1)V-BOX Settings**
1617 1617  
... ... @@ -1656,19 +1656,18 @@
1656 1656  
1657 1657  [[image:image-20220831155157-3.png]]
1658 1658  
1659 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1660 1660  
1661 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1662 1662  
1663 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1664 1664  
1665 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1666 1666  
1667 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1668 1668  
1796 +== **EC55 Series ** ==
1669 1669  
1670 -== **EC55 Series Protocol** ==
1671 -
1672 1672  Supported device: EC55 temperature instrument
1673 1673  
1674 1674  **1)V-BOX Settings**
... ... @@ -1728,9 +1728,9 @@
1728 1728  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1729 1729  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1730 1730  
1731 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1732 1732  
1733 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1734 1734  
1735 1735  **1)V-BOX Settings**
1736 1736  
... ... @@ -1772,7 +1772,7 @@
1772 1772  
1773 1773  [[image:image-20220831163441-4.png]]
1774 1774  
1775 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1776 1776  
1777 1777  **1)V-BOX Settings**
1778 1778  
... ... @@ -1846,7 +1846,7 @@
1846 1846  
1847 1847  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1848 1848  
1849 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1850 1850  
1851 1851  == **Schneider MODBUS RTU** ==
1852 1852  
... ... @@ -1880,9 +1880,9 @@
1880 1880  
1881 1881  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1882 1882  
1883 -= Create communication with Inovance** PLC** =
2009 += Inovance =
1884 1884  
1885 -== **H3U serial protocol** ==
2011 +== **H3U serial** ==
1886 1886  
1887 1887  **1)V-BOX Settings**
1888 1888  
... ... @@ -1932,9 +1932,9 @@
1932 1932  
1933 1933  [[image:image-20220831164731-4.png]]
1934 1934  
1935 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
1936 1936  
1937 -== **FP serial protocol** ==
2063 +== **FP serial** ==
1938 1938  
1939 1939  **1)V-BOX Settings**
1940 1940  
... ... @@ -1982,9 +1982,9 @@
1982 1982  
1983 1983  [[image:image-20220831165008-1.png]]
1984 1984  
1985 -= Create communication with LS** PLC** =
2111 += LS =
1986 1986  
1987 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
1988 1988  
1989 1989  **1)V-BOX Settings**
1990 1990  
... ... @@ -2036,7 +2036,7 @@
2036 2036  
2037 2037  [[image:image-20220831170215-2.png]]
2038 2038  
2039 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
2040 2040  
2041 2041  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2042 2042  
... ... @@ -2079,8 +2079,76 @@
2079 2079  
2080 2080  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2081 2081  
2082 -= Create communication with **Modbus ** =
2208 += INVT =
2083 2083  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
2084 2084  == **MODBUS RTU Slave (All function)** ==
2085 2085  
2086 2086  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -2090,7 +2090,7 @@
2090 2090  (% style="text-align:center" %)
2091 2091  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
2092 2092  
2093 -== **Communicate with Modbus Meter** ==
2287 +== **Modbus Meter** ==
2094 2094  
2095 2095  The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2096 2096  
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content