Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 234.1
edited by Hunter
on 2023/05/06 14:30
on 2023/05/06 14:30
Change comment:
There is no comment for this version
To version 258.1
edited by Theodore Xu
on 2023/08/23 19:34
on 2023/08/23 19:34
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 17 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.AiXia - Content
-
... ... @@ -1,6 +1,6 @@ 1 -= Create communication withWECONPLC=1 += WECON = 2 2 3 -== **LX3V Serial Protocol** ==3 +== **LX3V Serial ** == 4 4 5 5 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 ... ... @@ -48,7 +48,7 @@ 48 48 49 49 [[image:image-20220824120524-3.png]] 50 50 51 -== **LX5V Serial Protocol** ==51 +== **LX5V Serial ** == 52 52 53 53 This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 54 54 ... ... @@ -118,7 +118,7 @@ 118 118 119 119 The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 120 120 121 -== **LX5V-N Ethernet protocol** ==121 +== **LX5V-N Ethernet ** == 122 122 123 123 This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 124 124 ... ... @@ -176,9 +176,9 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication withAllen-Bradley(**Rockwell**)** PLC**=179 += Allen-Bradley(**Rockwell**) = 180 180 181 -== **DF1 Advanced Protocol** ==181 +== **DF1 Advanced Serial** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 184 ... ... @@ -277,7 +277,7 @@ 277 277 (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 278 (% id="cke_bm_5621S" style="display:none" %)** ** 279 279 280 -== **MicroLogix Protocol** ==280 +== **MicroLogix Serial** == 281 281 282 282 (% class="wikigeneratedid" %) 283 283 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -317,7 +317,7 @@ 317 317 318 318 [[image:image-20220824110724-1.png]] 319 319 320 -== **Micro850_FreeTag Protocol** ==320 +== **Micro850_FreeTag Ethernet** == 321 321 322 322 ((( 323 323 ((( ... ... @@ -520,7 +520,7 @@ 520 520 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 521 521 522 522 523 -== **Micro850_FreeTag Protocol(new)** ==523 +== **Micro850_FreeTag Ethernet(new)** == 524 524 525 525 This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 526 526 ... ... @@ -605,13 +605,13 @@ 605 605 606 606 ))) 607 607 608 -== **Ethernet DF1 Protocol** ==608 +== **Ethernet DF1** == 609 609 610 610 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 611 611 612 -= Create communication with**Crouzet PLC** =612 += **Crouzet PLC** = 613 613 614 -== **CROUZET M3 (FBD)** == 614 +== **CROUZET M3 (FBD) Serial** == 615 615 616 616 Support Series: Crouzet Millenium 3 CD12/CB12 617 617 ... ... @@ -663,15 +663,150 @@ 663 663 **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 664 664 {{/info}} 665 665 666 -= Create communication with **SiemensPLC**=666 += EMERSON = 667 667 668 -= =**S7-200Smart Ethernet Protocol** ==668 += **RTU Slave ** = 669 669 670 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]670 +Supported series: EC10 series 671 671 672 +**1)V-BOX setting** 672 672 673 -== **S7-300 Ethernet Protocol** == 674 +|**Items**|**Settings**|**Note** 675 +|Protocol|Emerson 984 RTU Slave MODBUS| 676 +|Connection|RS485| 677 +|Baud rate|19200| 678 +|Data bit|8| 679 +|Parity|EVEN| 680 +|Stop bit|1| 681 +|Device station No.|1|Need to be same as the PLC setting 674 674 683 +(% class="wikigeneratedid" %) 684 +**2)PLC Setting** 685 + 686 +(% class="wikigeneratedid" %) 687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 688 + 689 +(% style="text-align:center" %) 690 +[[image:ControlStarSystemBlock.png]] 691 + 692 +(% style="text-align:center" %) 693 +[[image:ControlStarCommunicate.png]] 694 + 695 +(% style="text-align:center" %) 696 +[[image:ControlStarModbus.png]] 697 + 698 +(% class="wikigeneratedid" %) 699 +**3)Address List** 700 + 701 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 703 +|X|XOOO|0~~377| 704 +|M0|M0DDDD|0~~2047| 705 +|M1|M1DDDDD|2048~~10239| 706 +|SM0|SM0DDD|0~~255| 707 +|SM1|SM1DDD|256~~511| 708 +|S0|S0DDDD|0~~1023| 709 +|S1|S1DDDD|1024~~4095| 710 +|T0|T0DDD|0~~255| 711 +|T1|T1DDD|256~~511| 712 +|C0|C0DDD|0~~255| 713 +|C1|C1DDD|256~~306| 714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 715 +|Z|ZDD|0~~15| 716 +|TW0|TW0DDD|0~~255| 717 +|TW1|TW1DDD|256~~511| 718 +|SD0|SD0DDD|0~~255| 719 +|SD1|SD1DDD|256~~511| 720 +|CW|CWDDD|0~~306| 721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 722 +|CW1|CW1DDDDD|256~~99999| 723 + 724 +**4) Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:Emerson.png]] 728 + 729 += HollySys PLC = 730 + 731 +== **LK Modbus RTU ** == 732 + 733 +Supported Series: HollySys LK series PLC 734 + 735 +**1)V-BOX setting** 736 + 737 +|**Items**|**Settings**|**Note** 738 +|Protocol|HollySys LK Modbus RTU| 739 +|Connection|RS485| 740 +|Baud rate|38400| 741 +|Data bit|8| 742 +|Parity|None| 743 +|Stop bit|1| 744 +|Device station No.|1| 745 + 746 +**2)Address List** 747 + 748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 749 +|Bit|QX|QXDDDDD.dd|0~~65535.15| 750 +|Bit|IX|IXDDDDD.dd|0~~65535.15| 751 +|Bit|MX|MXDDDDD.dd|0~~65535.15| 752 +|Word|QW|QWDDDDD|0~~99999| 753 +|Word|IW|IWDDDDD|0~~99999| 754 +|Word|MW|MWDDDDD|0~~99999| 755 +|Word|MD|MDDDDDD|0~~99999| 756 + 757 +**3)Cable Wiring** 758 + 759 +(% style="text-align:center" %) 760 +[[image:Hollysys485-2.png]] 761 + 762 +== **LM Modbus RTU** == 763 + 764 +(% class="wikigeneratedid" %) 765 +Supported Series: HollySys LM3109/LM3107 PLC 766 + 767 +(% class="wikigeneratedid" %) 768 +**1)V-BOX setting** 769 + 770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note** 771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %) 772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %) 773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %) 774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %) 775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %) 776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 778 + 779 +**2)Address List** 780 + 781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 782 +|Bit|QX|QXDDDDD.o|0~~99999.7| 783 +|Bit|IX|IXDDDDD.o|0~~99999.7| 784 +|Bit|MX|MXDDDDD.o|0~~99999.7| 785 +|Word|QW|QWDDDDD|0~~99999| 786 +|Word|IW|IWDDDDD|0~~99999| 787 +|Word|MW|MWDDDDD|0~~99999| 788 +|Word|MD|MDDDDDD|0~~99999| 789 + 790 +**Cable Wiring** 791 + 792 +RS232 793 + 794 +(% style="text-align:center" %) 795 +[[image:HollySysRS232.png]] 796 + 797 +RS485 798 + 799 +(% style="text-align:center" %) 800 +[[image:Hollysys LM Modbus RTU.gif]] 801 + 802 += **Siemens ** = 803 + 804 +== **S7-200 Smart Ethernet ** == 805 + 806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 807 + 808 +== **S7-300 Ethernet ** == 809 + 675 675 Supported Series: Siemens S7-300 series PLC 676 676 677 677 **1)V-BOX setting** ... ... @@ -728,11 +728,11 @@ 728 728 ))) 729 729 ))) 730 730 731 -== **S7-1200 Ethernet Protocol** ==866 +== **S7-1200 Ethernet ** == 732 732 733 733 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 734 734 735 -== **S7-XXX Ethernet Protocol** ==870 +== **S7-XXX Ethernet l** == 736 736 737 737 Supported Series: Siemens S7-400, S7-1200 and S7-1500 738 738 ... ... @@ -846,7 +846,7 @@ 846 846 847 847 [[image:image-20220824162342-2.png]] 848 848 849 -== **LOGO Ethernet Protocol** ==984 +== **LOGO Ethernet ** == 850 850 851 851 Supported Series: Siemens Logo 0BA0, 0BA1 series 852 852 ... ... @@ -937,9 +937,9 @@ 937 937 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 938 938 ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 939 939 940 -= Create communication with**MitsubishiPLC** =1075 += **Mitsubishi ** = 941 941 942 -== **FX1S,1N,2N Serial Protocol** ==1077 +== **FX1S,1N,2N Serial ** == 943 943 944 944 Supported Series: Mitsubishi FX1S, FX1N, FX2N series 945 945 ... ... @@ -986,7 +986,7 @@ 986 986 [[image:image-20220825100845-4.png]] 987 987 988 988 989 -== **FX3U,3G,3GA Serial Protocol** ==1124 +== **FX3U,3G,3GA Serial ** == 990 990 991 991 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 992 992 ... ... @@ -1033,7 +1033,7 @@ 1033 1033 [[image:image-20220825100845-4.png]] 1034 1034 1035 1035 1036 -== **FX3U Ethernet Protocol** ==1171 +== **FX3U Ethernet ** == 1037 1037 1038 1038 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 1039 1039 ... ... @@ -1128,7 +1128,7 @@ 1128 1128 1129 1129 [[image:image-20221119101946-2.png||height="395" width="695"]] 1130 1130 1131 -== **FX5U Serial Protocol** ==1266 +== **FX5U Serial ** == 1132 1132 1133 1133 Mitsubishi FX5U series PLC 1134 1134 ... ... @@ -1210,7 +1210,7 @@ 1210 1210 1211 1211 [[image:image-20220825105533-3.png]] 1212 1212 1213 -== **FX5U Ethernet Protocol** ==1348 +== **FX5U Ethernet ** == 1214 1214 1215 1215 Mitsubishi FX5U series PLC 1216 1216 ... ... @@ -1286,7 +1286,7 @@ 1286 1286 1287 1287 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1288 1288 1289 -== **L02 Serial Protocol** ==1424 +== **L02 Serial ** == 1290 1290 1291 1291 Mitsubishi L02 series CPU built-in serial port. 1292 1292 ... ... @@ -1346,7 +1346,7 @@ 1346 1346 1347 1347 [[image:image-20220825160820-4.png]] 1348 1348 1349 -== **L02 Ethernet Protocol** ==1484 +== **L02 Ethernet ** == 1350 1350 1351 1351 Mitsubishi L series CPU built-in Ethernet port. 1352 1352 ... ... @@ -1419,13 +1419,13 @@ 1419 1419 1420 1420 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1421 1421 1422 -== **Q12H Serial Protocol** ==1557 +== **Q12H Serial ** == 1423 1423 1424 1424 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1425 1425 1426 1426 [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1427 1427 1428 -== **QJ71E71 Ethernet Protocol** ==1563 +== **QJ71E71 Ethernet ** == 1429 1429 1430 1430 Mitsubishi QJ71E71 Ethernet communication module; 1431 1431 ... ... @@ -1500,9 +1500,9 @@ 1500 1500 1501 1501 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1502 1502 1503 -= Create communication with**DeltaPLC** =1638 += **Delta** = 1504 1504 1505 -== **DVP Ethernet Protocol** ==1640 +== **DVP Ethernet** == 1506 1506 1507 1507 Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1508 1508 ... ... @@ -1567,7 +1567,7 @@ 1567 1567 (% style="text-align:center" %) 1568 1568 [[image:DVPEthernetVNETPortocol.png]] 1569 1569 1570 -== **DVP serial protocol** ==1705 +== **DVP serial** == 1571 1571 1572 1572 Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1573 1573 ... ... @@ -1603,7 +1603,7 @@ 1603 1603 (% style="text-align:center" %) 1604 1604 [[image:Delta DVP PROTOCOLSerial232.png]] 1605 1605 1606 -== **AS Ethernet Protocol** ==1741 +== **AS Ethernet** == 1607 1607 1608 1608 **1)V-BOX Settings** 1609 1609 ... ... @@ -1648,19 +1648,18 @@ 1648 1648 1649 1649 [[image:image-20220831155157-3.png]] 1650 1650 1651 -= Create communication with**OmronPLC** =1786 += **Omron** = 1652 1652 1653 -== **CP1 Series Protocol** ==1788 +== **CP1 Series** == 1654 1654 1655 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1656 1656 1657 -== **CP2M Series Protocol** ==1792 +== **CP2M Series** == 1658 1658 1659 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1660 1660 1796 +== **EC55 Series ** == 1661 1661 1662 -== **EC55 Series Protocol** == 1663 - 1664 1664 Supported device: EC55 temperature instrument 1665 1665 1666 1666 **1)V-BOX Settings** ... ... @@ -1720,9 +1720,9 @@ 1720 1720 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1721 1721 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1722 1722 1723 -= Create communication withXinje** PLC**=1857 += Xinje = 1724 1724 1725 -== **XC serial protocol** ==1859 +== **XC serial** == 1726 1726 1727 1727 **1)V-BOX Settings** 1728 1728 ... ... @@ -1764,7 +1764,7 @@ 1764 1764 1765 1765 [[image:image-20220831163441-4.png]] 1766 1766 1767 -== **XD serial protocol** ==1901 +== **XD serial** == 1768 1768 1769 1769 **1)V-BOX Settings** 1770 1770 ... ... @@ -1838,7 +1838,7 @@ 1838 1838 1839 1839 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1840 1840 1841 -= Create communication with**SchneiderPLC** =1975 += **Schneider** = 1842 1842 1843 1843 == **Schneider MODBUS RTU** == 1844 1844 ... ... @@ -1872,9 +1872,9 @@ 1872 1872 1873 1873 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1874 1874 1875 -= Create communication withInovance** PLC**=2009 += Inovance = 1876 1876 1877 -== **H3U serial protocol** ==2011 +== **H3U serial** == 1878 1878 1879 1879 **1)V-BOX Settings** 1880 1880 ... ... @@ -1924,9 +1924,9 @@ 1924 1924 1925 1925 [[image:image-20220831164731-4.png]] 1926 1926 1927 -= Create communication withPanasonic** PLC**=2061 += Panasonic = 1928 1928 1929 -== **FP serial protocol** ==2063 +== **FP serial** == 1930 1930 1931 1931 **1)V-BOX Settings** 1932 1932 ... ... @@ -1974,9 +1974,9 @@ 1974 1974 1975 1975 [[image:image-20220831165008-1.png]] 1976 1976 1977 -= Create communication withLS** PLC**=2111 += LS = 1978 1978 1979 -== **XBC serial protocol** ==2113 +== **XBC serial** == 1980 1980 1981 1981 **1)V-BOX Settings** 1982 1982 ... ... @@ -2028,7 +2028,7 @@ 2028 2028 2029 2029 [[image:image-20220831170215-2.png]] 2030 2030 2031 -== **XGK FEnet Ethernet protocol** ==2165 +== **XGK FEnet Ethernet** == 2032 2032 2033 2033 Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2034 2034 ... ... @@ -2071,8 +2071,76 @@ 2071 2071 2072 2072 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2073 2073 2074 -= Createcommunication with **Modbus **=2208 += INVT = 2075 2075 2210 +**1)V-BOX setting** 2211 + 2212 +|**Item**|**Settings**|**Note** 2213 +|Protocol|INVT_IVC2L| 2214 +|Connection|RS232| 2215 +|Baud rate|19200| 2216 +|Data bit|8| 2217 +|Parity|EVEN| 2218 +|Stop bit|1| 2219 +|PLC station No.|1 2220 + 2221 +**2)Address List** 2222 + 2223 + 2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377| 2226 +|Y|YOOO|0~~377| 2227 +|M|MDDDD|0~~1999| 2228 +|SM|SMDDD|0~~255| 2229 +|S|SDDD|0~~991| 2230 +|T|TDDD|0~~255| 2231 +|C|CDDD|0~~255| 2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999| 2233 +|SD|SDDDD|0~~255| 2234 +|Z|ZDD|0~~15| 2235 +|T|TDDD|0~~255| 2236 +|C|CDDD|0~~199| 2237 +|Double word|C|CDDD|200~~255| 2238 + 2239 +**3)Communication Settings** 2240 + 2241 +(% style="text-align:center" %) 2242 +[[image:盒子创建英威腾.png]] 2243 + 2244 +**4)PLC software** 2245 + 2246 +(% style="text-align:center" %) 2247 +[[image:英威腾软件.png]] 2248 + 2249 +**5)PLC setting ** 2250 + 2251 +Open the INVI plc software, create a new project or open a project that has already been created 2252 + 2253 +(% style="text-align:center" %) 2254 +[[image:英威腾创建1.png]] 2255 + 2256 +Configure serial port parameters. 2257 + 2258 +(% style="text-align:center" %) 2259 +[[image:英威腾创建2.png]] 2260 + 2261 +PC connect PLC 2262 + 2263 +(% style="text-align:center" %) 2264 +[[image:英威腾创建3.png]] 2265 + 2266 +Download 2267 + 2268 +(% style="text-align:center" %) 2269 +[[image:英威腾下载.png]] 2270 + 2271 +**6)Cable Wiring** 2272 + 2273 +(% style="text-align:center" %) 2274 +[[image:wire.png]] 2275 + 2276 += **Modbus ** = 2277 + 2076 2076 == **MODBUS RTU Slave (All function)** == 2077 2077 2078 2078 Select the protocol "Modbus RTU Slave (All Fuction)", ... ... @@ -2082,7 +2082,7 @@ 2082 2082 (% style="text-align:center" %) 2083 2083 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 2084 2084 2085 -== ** Communicate withModbus Meter** ==2287 +== **Modbus Meter** == 2086 2086 2087 2087 The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2088 2088
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- HollySysRS232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- Hollysys LM Modbus RTU.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.4 KB - Content
- plc 软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.8 KB - Content
- wire.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content
- 企业微信截图_16889606174191.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.7 KB - Content
- 盒子创建英威腾.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.5 KB - Content
- 英威腾下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.0 KB - Content
- 英威腾创建1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- 英威腾创建2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.7 KB - Content
- 英威腾创建3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.6 KB - Content
- 英威腾软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.6 KB - Content