Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 235.1
edited by Hunter
on 2023/05/06 14:31
on 2023/05/06 14:31
Change comment:
There is no comment for this version
To version 257.1
edited by Theodore Xu
on 2023/08/23 19:31
on 2023/08/23 19:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 17 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.AiXia - Content
-
... ... @@ -1,6 +1,6 @@ 1 -= Create communication withWECONPLC=1 += WECON = 2 2 3 -== **LX3V Serial Protocol** ==3 +== **LX3V Serial ** == 4 4 5 5 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 ... ... @@ -48,7 +48,7 @@ 48 48 49 49 [[image:image-20220824120524-3.png]] 50 50 51 -== **LX5V Serial Protocol** ==51 +== **LX5V Serial ** == 52 52 53 53 This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 54 54 ... ... @@ -118,7 +118,7 @@ 118 118 119 119 The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 120 120 121 -== **LX5V-N Ethernet protocol** ==121 +== **LX5V-N Ethernet ** == 122 122 123 123 This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 124 124 ... ... @@ -176,9 +176,9 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication withAllen-Bradley(**Rockwell**)** PLC**=179 += Allen-Bradley(**Rockwell**) = 180 180 181 -== **DF1 Advanced Protocol** ==181 +== **DF1 Advanced Serial** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 184 ... ... @@ -277,7 +277,7 @@ 277 277 (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 278 (% id="cke_bm_5621S" style="display:none" %)** ** 279 279 280 -== **MicroLogix Protocol** ==280 +== **MicroLogix Serial** == 281 281 282 282 (% class="wikigeneratedid" %) 283 283 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -317,7 +317,7 @@ 317 317 318 318 [[image:image-20220824110724-1.png]] 319 319 320 -== **Micro850_FreeTag Protocol** ==320 +== **Micro850_FreeTag Ethernet** == 321 321 322 322 ((( 323 323 ((( ... ... @@ -520,7 +520,7 @@ 520 520 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 521 521 522 522 523 -== **Micro850_FreeTag Protocol(new)** ==523 +== **Micro850_FreeTag Ethernet(new)** == 524 524 525 525 This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 526 526 ... ... @@ -663,18 +663,150 @@ 663 663 **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 664 664 {{/info}} 665 665 666 -= Create communication with **EMERSONPLC**=666 += EMERSON = 667 667 668 += **RTU Slave ** = 668 668 669 - = Createcommunication with **SiemensPLC**=670 +Supported series: EC10 series 670 670 671 - ==**S7-200Smart EthernetProtocol**==672 +**1)V-BOX setting** 672 672 673 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 674 +|**Items**|**Settings**|**Note** 675 +|Protocol|Emerson 984 RTU Slave MODBUS| 676 +|Connection|RS485| 677 +|Baud rate|19200| 678 +|Data bit|8| 679 +|Parity|EVEN| 680 +|Stop bit|1| 681 +|Device station No.|1|Need to be same as the PLC setting 674 674 683 +(% class="wikigeneratedid" %) 684 +**2)PLC Setting** 675 675 676 -== **S7-300 Ethernet Protocol** == 686 +(% class="wikigeneratedid" %) 687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 677 677 689 +(% style="text-align:center" %) 690 +[[image:ControlStarSystemBlock.png]] 691 + 692 +(% style="text-align:center" %) 693 +[[image:ControlStarCommunicate.png]] 694 + 695 +(% style="text-align:center" %) 696 +[[image:ControlStarModbus.png]] 697 + 698 +(% class="wikigeneratedid" %) 699 +**3)Address List** 700 + 701 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 703 +|X|XOOO|0~~377| 704 +|M0|M0DDDD|0~~2047| 705 +|M1|M1DDDDD|2048~~10239| 706 +|SM0|SM0DDD|0~~255| 707 +|SM1|SM1DDD|256~~511| 708 +|S0|S0DDDD|0~~1023| 709 +|S1|S1DDDD|1024~~4095| 710 +|T0|T0DDD|0~~255| 711 +|T1|T1DDD|256~~511| 712 +|C0|C0DDD|0~~255| 713 +|C1|C1DDD|256~~306| 714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 715 +|Z|ZDD|0~~15| 716 +|TW0|TW0DDD|0~~255| 717 +|TW1|TW1DDD|256~~511| 718 +|SD0|SD0DDD|0~~255| 719 +|SD1|SD1DDD|256~~511| 720 +|CW|CWDDD|0~~306| 721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 722 +|CW1|CW1DDDDD|256~~99999| 723 + 724 +**4) Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:Emerson.png]] 728 + 729 += HollySys PLC = 730 + 731 +== **LK Modbus RTU ** == 732 + 733 +Supported Series: HollySys LK series PLC 734 + 735 +**1)V-BOX setting** 736 + 737 +|**Items**|**Settings**|**Note** 738 +|Protocol|HollySys LK Modbus RTU| 739 +|Connection|RS485| 740 +|Baud rate|38400| 741 +|Data bit|8| 742 +|Parity|None| 743 +|Stop bit|1| 744 +|Device station No.|1| 745 + 746 +**2)Address List** 747 + 748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 749 +|Bit|QX|QXDDDDD.dd|0~~65535.15| 750 +|Bit|IX|IXDDDDD.dd|0~~65535.15| 751 +|Bit|MX|MXDDDDD.dd|0~~65535.15| 752 +|Word|QW|QWDDDDD|0~~99999| 753 +|Word|IW|IWDDDDD|0~~99999| 754 +|Word|MW|MWDDDDD|0~~99999| 755 +|Word|MD|MDDDDDD|0~~99999| 756 + 757 +**3)Cable Wiring** 758 + 759 +(% style="text-align:center" %) 760 +[[image:Hollysys485-2.png]] 761 + 762 +== **LM Modbus RTU** == 763 + 764 +(% class="wikigeneratedid" %) 765 +Supported Series: HollySys LM3109/LM3107 PLC 766 + 767 +(% class="wikigeneratedid" %) 768 +**1)V-BOX setting** 769 + 770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note** 771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %) 772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %) 773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %) 774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %) 775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %) 776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 778 + 779 +**2)Address List** 780 + 781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 782 +|Bit|QX|QXDDDDD.o|0~~99999.7| 783 +|Bit|IX|IXDDDDD.o|0~~99999.7| 784 +|Bit|MX|MXDDDDD.o|0~~99999.7| 785 +|Word|QW|QWDDDDD|0~~99999| 786 +|Word|IW|IWDDDDD|0~~99999| 787 +|Word|MW|MWDDDDD|0~~99999| 788 +|Word|MD|MDDDDDD|0~~99999| 789 + 790 +**Cable Wiring** 791 + 792 +RS232 793 + 794 +(% style="text-align:center" %) 795 +[[image:HollySysRS232.png]] 796 + 797 +RS485 798 + 799 +(% style="text-align:center" %) 800 +[[image:Hollysys LM Modbus RTU.gif]] 801 + 802 += **Siemens ** = 803 + 804 +== **S7-200 Smart Ethernet ** == 805 + 806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 807 + 808 +== **S7-300 Ethernet ** == 809 + 678 678 Supported Series: Siemens S7-300 series PLC 679 679 680 680 **1)V-BOX setting** ... ... @@ -731,11 +731,11 @@ 731 731 ))) 732 732 ))) 733 733 734 -== **S7-1200 Ethernet Protocol** ==866 +== **S7-1200 Ethernet ** == 735 735 736 736 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 737 737 738 -== **S7-XXX Ethernet Protocol** ==870 +== **S7-XXX Ethernet l** == 739 739 740 740 Supported Series: Siemens S7-400, S7-1200 and S7-1500 741 741 ... ... @@ -849,7 +849,7 @@ 849 849 850 850 [[image:image-20220824162342-2.png]] 851 851 852 -== **LOGO Ethernet Protocol** ==984 +== **LOGO Ethernet ** == 853 853 854 854 Supported Series: Siemens Logo 0BA0, 0BA1 series 855 855 ... ... @@ -940,9 +940,9 @@ 940 940 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 941 941 ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 942 942 943 -= Create communication with**MitsubishiPLC** =1075 += **Mitsubishi ** = 944 944 945 -== **FX1S,1N,2N Serial Protocol** ==1077 +== **FX1S,1N,2N Serial ** == 946 946 947 947 Supported Series: Mitsubishi FX1S, FX1N, FX2N series 948 948 ... ... @@ -989,7 +989,7 @@ 989 989 [[image:image-20220825100845-4.png]] 990 990 991 991 992 -== **FX3U,3G,3GA Serial Protocol** ==1124 +== **FX3U,3G,3GA Serial ** == 993 993 994 994 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 995 995 ... ... @@ -1036,7 +1036,7 @@ 1036 1036 [[image:image-20220825100845-4.png]] 1037 1037 1038 1038 1039 -== **FX3U Ethernet Protocol** ==1171 +== **FX3U Ethernet ** == 1040 1040 1041 1041 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 1042 1042 ... ... @@ -1131,7 +1131,7 @@ 1131 1131 1132 1132 [[image:image-20221119101946-2.png||height="395" width="695"]] 1133 1133 1134 -== **FX5U Serial Protocol** ==1266 +== **FX5U Serial ** == 1135 1135 1136 1136 Mitsubishi FX5U series PLC 1137 1137 ... ... @@ -1213,7 +1213,7 @@ 1213 1213 1214 1214 [[image:image-20220825105533-3.png]] 1215 1215 1216 -== **FX5U Ethernet Protocol** ==1348 +== **FX5U Ethernet ** == 1217 1217 1218 1218 Mitsubishi FX5U series PLC 1219 1219 ... ... @@ -1289,7 +1289,7 @@ 1289 1289 1290 1290 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1291 1291 1292 -== **L02 Serial Protocol** ==1424 +== **L02 Serial ** == 1293 1293 1294 1294 Mitsubishi L02 series CPU built-in serial port. 1295 1295 ... ... @@ -1349,7 +1349,7 @@ 1349 1349 1350 1350 [[image:image-20220825160820-4.png]] 1351 1351 1352 -== **L02 Ethernet Protocol** ==1484 +== **L02 Ethernet ** == 1353 1353 1354 1354 Mitsubishi L series CPU built-in Ethernet port. 1355 1355 ... ... @@ -1422,13 +1422,13 @@ 1422 1422 1423 1423 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1424 1424 1425 -== **Q12H Serial Protocol** ==1557 +== **Q12H Serial ** == 1426 1426 1427 1427 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1428 1428 1429 1429 [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1430 1430 1431 -== **QJ71E71 Ethernet Protocol** ==1563 +== **QJ71E71 Ethernet ** == 1432 1432 1433 1433 Mitsubishi QJ71E71 Ethernet communication module; 1434 1434 ... ... @@ -1503,9 +1503,9 @@ 1503 1503 1504 1504 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1505 1505 1506 -= Create communication with**DeltaPLC** =1638 += **Delta** = 1507 1507 1508 -== **DVP Ethernet Protocol** ==1640 +== **DVP Ethernet** == 1509 1509 1510 1510 Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1511 1511 ... ... @@ -1570,7 +1570,7 @@ 1570 1570 (% style="text-align:center" %) 1571 1571 [[image:DVPEthernetVNETPortocol.png]] 1572 1572 1573 -== **DVP serial protocol** ==1705 +== **DVP serial** == 1574 1574 1575 1575 Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1576 1576 ... ... @@ -1606,7 +1606,7 @@ 1606 1606 (% style="text-align:center" %) 1607 1607 [[image:Delta DVP PROTOCOLSerial232.png]] 1608 1608 1609 -== **AS Ethernet Protocol** ==1741 +== **AS Ethernet** == 1610 1610 1611 1611 **1)V-BOX Settings** 1612 1612 ... ... @@ -1651,19 +1651,18 @@ 1651 1651 1652 1652 [[image:image-20220831155157-3.png]] 1653 1653 1654 -= Create communication with**OmronPLC** =1786 += **Omron** = 1655 1655 1656 -== **CP1 Series Protocol** ==1788 +== **CP1 Series** == 1657 1657 1658 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1659 1659 1660 -== **CP2M Series Protocol** ==1792 +== **CP2M Series** == 1661 1661 1662 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1663 1663 1796 +== **EC55 Series ** == 1664 1664 1665 -== **EC55 Series Protocol** == 1666 - 1667 1667 Supported device: EC55 temperature instrument 1668 1668 1669 1669 **1)V-BOX Settings** ... ... @@ -1723,9 +1723,9 @@ 1723 1723 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1724 1724 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1725 1725 1726 -= Create communication withXinje** PLC**=1857 += Xinje = 1727 1727 1728 -== **XC serial protocol** ==1859 +== **XC serial** == 1729 1729 1730 1730 **1)V-BOX Settings** 1731 1731 ... ... @@ -1767,7 +1767,7 @@ 1767 1767 1768 1768 [[image:image-20220831163441-4.png]] 1769 1769 1770 -== **XD serial protocol** ==1901 +== **XD serial** == 1771 1771 1772 1772 **1)V-BOX Settings** 1773 1773 ... ... @@ -1841,7 +1841,7 @@ 1841 1841 1842 1842 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1843 1843 1844 -= Create communication with**SchneiderPLC** =1975 += **Schneider** = 1845 1845 1846 1846 == **Schneider MODBUS RTU** == 1847 1847 ... ... @@ -1875,7 +1875,7 @@ 1875 1875 1876 1876 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1877 1877 1878 -= Create communication withInovance** PLC**=2009 += Inovance = 1879 1879 1880 1880 == **H3U serial protocol** == 1881 1881 ... ... @@ -1927,9 +1927,9 @@ 1927 1927 1928 1928 [[image:image-20220831164731-4.png]] 1929 1929 1930 -= Create communication withPanasonic** PLC**=2061 += Panasonic = 1931 1931 1932 -== **FP serial protocol** ==2063 +== **FP serial** == 1933 1933 1934 1934 **1)V-BOX Settings** 1935 1935 ... ... @@ -1977,9 +1977,9 @@ 1977 1977 1978 1978 [[image:image-20220831165008-1.png]] 1979 1979 1980 -= Create communication withLS** PLC**=2111 += LS = 1981 1981 1982 -== **XBC serial protocol** ==2113 +== **XBC serial** == 1983 1983 1984 1984 **1)V-BOX Settings** 1985 1985 ... ... @@ -2031,7 +2031,7 @@ 2031 2031 2032 2032 [[image:image-20220831170215-2.png]] 2033 2033 2034 -== **XGK FEnet Ethernet protocol** ==2165 +== **XGK FEnet Ethernet** == 2035 2035 2036 2036 Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2037 2037 ... ... @@ -2074,8 +2074,76 @@ 2074 2074 2075 2075 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2076 2076 2077 -= Createcommunication with **Modbus **=2208 += INVT = 2078 2078 2210 +**1)V-BOX setting** 2211 + 2212 +|**Item**|**Settings**|**Note** 2213 +|Protocol|INVT_IVC2L| 2214 +|Connection|RS232| 2215 +|Baud rate|19200| 2216 +|Data bit|8| 2217 +|Parity|EVEN| 2218 +|Stop bit|1| 2219 +|PLC station No.|1 2220 + 2221 +**2)Address List** 2222 + 2223 + 2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377| 2226 +|Y|YOOO|0~~377| 2227 +|M|MDDDD|0~~1999| 2228 +|SM|SMDDD|0~~255| 2229 +|S|SDDD|0~~991| 2230 +|T|TDDD|0~~255| 2231 +|C|CDDD|0~~255| 2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999| 2233 +|SD|SDDDD|0~~255| 2234 +|Z|ZDD|0~~15| 2235 +|T|TDDD|0~~255| 2236 +|C|CDDD|0~~199| 2237 +|Double word|C|CDDD|200~~255| 2238 + 2239 +**3)Communication Settings** 2240 + 2241 +(% style="text-align:center" %) 2242 +[[image:盒子创建英威腾.png]] 2243 + 2244 +**4)PLC software** 2245 + 2246 +(% style="text-align:center" %) 2247 +[[image:英威腾软件.png]] 2248 + 2249 +**5)PLC setting ** 2250 + 2251 +Open the INVI plc software, create a new project or open a project that has already been created 2252 + 2253 +(% style="text-align:center" %) 2254 +[[image:英威腾创建1.png]] 2255 + 2256 +Configure serial port parameters. 2257 + 2258 +(% style="text-align:center" %) 2259 +[[image:英威腾创建2.png]] 2260 + 2261 +PC connect PLC 2262 + 2263 +(% style="text-align:center" %) 2264 +[[image:英威腾创建3.png]] 2265 + 2266 +Download 2267 + 2268 +(% style="text-align:center" %) 2269 +[[image:英威腾下载.png]] 2270 + 2271 +**6)Cable Wiring** 2272 + 2273 +(% style="text-align:center" %) 2274 +[[image:wire.png]] 2275 + 2276 += **Modbus ** = 2277 + 2079 2079 == **MODBUS RTU Slave (All function)** == 2080 2080 2081 2081 Select the protocol "Modbus RTU Slave (All Fuction)", ... ... @@ -2085,7 +2085,7 @@ 2085 2085 (% style="text-align:center" %) 2086 2086 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 2087 2087 2088 -== ** Communicate withModbus Meter** ==2287 +== **Modbus Meter** == 2089 2089 2090 2090 The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2091 2091
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- HollySysRS232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- Hollysys LM Modbus RTU.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.4 KB - Content
- plc 软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.8 KB - Content
- wire.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content
- 企业微信截图_16889606174191.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.7 KB - Content
- 盒子创建英威腾.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.5 KB - Content
- 英威腾下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.0 KB - Content
- 英威腾创建1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- 英威腾创建2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.7 KB - Content
- 英威腾创建3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.6 KB - Content
- 英威腾软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.6 KB - Content