1 -= Create communication with WECON PLC =
1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**1)V-BOX setting**
7 +**1)PLC Settings**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,9 +15,8 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**2)Address List**
18 +**2)PLC Address List**
19 19  
20 -
21 21  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
22 22  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
23 23  |Y|Y|Y o|0~~303237|
... ... @@ -36,9 +36,9 @@
36 36  
37 37  **3)Configure the communication protocol**
38 38  
39 -[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]]
38 +[[image:image-20220824152217-1.png]]
40 40  
41 -**4)Cable Wiring**
40 +**4)hardware connection**
42 42  
43 43  * **RS422**
44 44  
... ... @@ -176,116 +176,16 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
178 += **Rockwell PLC** =
180 180  
181 -== **DF1 Advanced Protocol** ==
180 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
182 182  
183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 -
185 -**1) V-Box Settings**
186 -
187 -|=Item|=Recommended |=Note
188 -|=Protocol|Allen Bradley DF1 Advanced|
189 -|=Connection|RS232|
190 -|=Baud rate|19200|
191 -|=Stop bits|1|
192 -|=Data bits|8|
193 -|=Parity|None|
194 -|=PLC Station No.|1|
195 -|=HMI Station No.|0|
196 -
197 -**2) Address List**
198 -
199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 -|BN|BNddddd.dd|0.0~~99255.15|(((
205 -Bit data file B0~~B99
206 -
207 -First two digits is for file number
208 -
209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 -)))
211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 -|NN|NNddddd.dd|0.0~~99255.15|(((
213 -Integer data file bit format N0~~N99
214 -
215 -First two digits is for file number
216 -
217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 -)))
219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 -|TNS|TNSddddd|0~~99255|(((
223 -Timer Preset Value
224 -
225 -First two digits is for file number
226 -
227 -For example, TNS99255 represents file number T99, address 255.
228 -)))
229 -|TNP|TNPddddd|0~~99255|(((
230 -Timer Accumulator Value
231 -
232 -First two digits is for file number
233 -
234 -For example, TNP99255 represents file number T99, address 255.
235 -)))
236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 -|CNS|CNSddddd|0~~99255|(((
239 -Counter Preset Value
240 -
241 -First two digits is for file number
242 -
243 -For example, CNS99255 represents file number C99, address 255.
244 -)))
245 -|CNP|CNPddddd|0~~99255|(((
246 -Counter Accumulator Value
247 -
248 -First two digits is for file number
249 -
250 -For example, CNP99255 represents file number C99, address 255.
251 -)))
252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 -|NN|NNddd|0~~99255|(((
254 -Integer data file
255 -
256 -First two digits is for file number
257 -
258 -For example, NN99255 represents file number N99, address 255.
259 -)))
260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 -Only able to communicate with file number N7
262 -)))
263 -|FN|FNddddd|0~~99255|(((
264 -Floating point data file
265 -
266 -First two digits is for file number
267 -
268 -For example, FN99255 represents file number F99, address 255.
269 -)))
270 -|LN|LNddddd|0~~99255|Long
271 -
272 -**3) Cable Wiring**
273 -
274 -(% style="text-align:center" %)
275 -[[image:ABRS232.gif]]
276 -
277 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 -(% id="cke_bm_5621S" style="display:none" %)** **
279 -
280 -== **MicroLogix Protocol** ==
281 -
282 -(% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
284 284  
285 -**1)V-BOX setting**
184 +**1)PLC Settings**
286 286  
287 287  |**Item**|**Settings**|**Note**
288 -|Protocol|Allen-Bradley DF1 Advanced|
187 +|Protocol|Allen-Bradlley DF1 Advanced|
289 289  |Connection|RS232|
290 290  |Baud rate|19200|
291 291  |Data bit|8|
... ... @@ -317,7 +317,7 @@
317 317  
318 318  [[image:image-20220824110724-1.png]]
319 319  
320 -== **Micro850_FreeTag Protocol** ==
219 +== **CompactLogix Protocol** ==
321 321  
322 322  (((
323 323  (((
... ... @@ -456,7 +456,7 @@
456 456  
457 457  (((
458 458  (((
459 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
358 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
460 460  )))
461 461  
462 462  
... ... @@ -520,214 +520,13 @@
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 522  
523 -== **Micro850_FreeTag Protocol(new)** ==
422 +== **Allen-Bradley Ethernet DF1** ==
524 524  
525 -This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 -
527 -(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 -(((
529 -**Software configuration of PLC**
530 -)))
531 -
532 -(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 -(((
534 -**1)PLC programming software:Connected Components Workbench™**
535 -
536 -(% style="text-align:center" %)
537 -[[image:software.png]]
538 -
539 -**2)New PLC project**
540 -
541 -Click New Project and select the PLC model.
542 -
543 -(% style="text-align:center" %)
544 -[[image:project create.png]]
545 -
546 -**3)Set Ethernet parameters**
547 -
548 -Follow the steps below to configure Ethernet parameters
549 -
550 -PLC IP address:192.168.39.56
551 -
552 -default gateway:192.168.39.1
553 -
554 -subnet mask:255.255.255.0
555 -
556 -(% style="text-align:center" %)
557 -[[image:Ethernet.png]]
558 -
559 -**4)connect PLC**
560 -
561 -**When downloading the setting, need to change the status of the PLC to PRG**
562 -
563 -(% style="text-align:center" %)
564 -[[image:conne ab plc.png]]
565 -
566 -**V-box software configuration**
567 -
568 -**1)V-box programming software**
569 -
570 -(% style="text-align:center" %)
571 -[[image:v-net client vers.png]]
572 -
573 -**2)Set communication port parameters**
574 -
575 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 -
577 -(% style="text-align:center" %)
578 -[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 -
580 -The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 -
582 -(% style="text-align:center" %)
583 -[[image:V-NET_Client_communication.png]]
584 -
585 -Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
586 -
587 -(% style="text-align:center" %)
588 -[[image:export1.png]]
589 -
590 -(% style="text-align:center" %)
591 -[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 -
593 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
594 -
595 -(% style="text-align:center" %)
596 -[[image:V-NET_Client_TNBuqy7T5r.png]]
597 -
598 -**3)Engineering production**
599 -
600 -According to your own needs, use the V-NET client software to edit the required data monitoring points.
601 -
602 -(% style="text-align:center" %)
603 -[[image:V-NET_Client_KOR0AHEA4M.png]]
604 -
605 -
606 -)))
607 -
608 -== **Ethernet DF1 Protocol** ==
609 -
610 610  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
611 611  
612 -= Create communication with **Crouzet PLC** =
613 613  
614 -== **CROUZET M3 (FBD)** ==
427 += **Siemens PLC** =
615 615  
616 -Support Series: Crouzet Millenium 3 CD12/CB12
617 -
618 -**1)V-BOX setting**
619 -
620 -|=Item|=Recommended |=Note
621 -|=Protocol|CROUZET M3 (FBD)|
622 -|=Connection|RS232|
623 -|=Baud rate|115200|
624 -|=Stop bits|1|
625 -|=Data bits|7|
626 -|=Parity|EVEN|
627 -
628 -**2)Address List**
629 -
630 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
631 -|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
632 -|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
633 -|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
634 -|State|State D|1~~1|PLC state(Read only)
635 -|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
636 -|SLIn|SLIn DD|1~~24|Serial Link Input
637 -|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
638 -|Time|Time D|1~~6|(((
639 -Time1: Second
640 -
641 -Time2: Minute
642 -
643 -Time3: Hour
644 -
645 -Time4: Day
646 -
647 -Time5: Month
648 -
649 -Time6: Year
650 -)))
651 -|Order|Order D|1~~1|(((
652 -Running command(Write only)
653 -
654 -~=2: Run mode; =1: Stop mode;
655 -)))
656 -
657 -**3)Cable Wiring**
658 -
659 -(% style="text-align:center" %)
660 -[[image:CrouzetRS232 VBox.png]]
661 -
662 -{{info}}
663 -**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 -{{/info}}
665 -
666 -= Create communication with EMERSON PLC =
667 -
668 -== **RTU Slave Protocol** ==
669 -
670 -Supported series: EC10 series
671 -
672 -**1)V-BOX setting**
673 -
674 -|**Items**|**Settings**|**Note**
675 -|Protocol|Emerson 984 RTU Slave MODBUS|
676 -|Connection|RS485|
677 -|Baud rate|19200|
678 -|Data bit|8|
679 -|Parity|EVEN|
680 -|Stop bit|1|
681 -|Device station No.|1|Need to be same as the PLC setting
682 -
683 -(% class="wikigeneratedid" %)
684 -**2)PLC Setting**
685 -
686 -(% class="wikigeneratedid" %)
687 -Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
688 -
689 -(% style="text-align:center" %)
690 -[[image:ControlStarSystemBlock.png]]
691 -
692 -(% style="text-align:center" %)
693 -[[image:ControlStarCommunicate.png]]
694 -
695 -(% style="text-align:center" %)
696 -[[image:ControlStarModbus.png]]
697 -
698 -(% class="wikigeneratedid" %)
699 -**3)Address List**
700 -
701 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 -|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 -|X|XOOO|0~~377|
704 -|M0|M0DDDD|0~~2047|
705 -|M1|M1DDDDD|2048~~10239|
706 -|SM0|SM0DDD|0~~255|
707 -|SM1|SM1DDD|256~~511|
708 -|S0|S0DDDD|0~~1023|
709 -|S1|S1DDDD|1024~~4095|
710 -|T0|T0DDD|0~~255|
711 -|T1|T1DDD|256~~511|
712 -|C0|C0DDD|0~~255|
713 -|C1|C1DDD|256~~306|
714 -|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 -|Z|ZDD|0~~15|
716 -|TW0|TW0DDD|0~~255|
717 -|TW1|TW1DDD|256~~511|
718 -|SD0|SD0DDD|0~~255|
719 -|SD1|SD1DDD|256~~511|
720 -|CW|CWDDD|0~~306|
721 -|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 -|CW1|CW1DDDDD|256~~99999|
723 -
724 -**4) Cable Wiring**
725 -
726 -(% style="text-align:center" %)
727 -[[image:Emerson.png]]
728 -
729 -= Create communication with **Siemens PLC** =
730 -
731 731  == **S7-200 Smart Ethernet Protocol** ==
732 732  
733 733  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
... ... @@ -737,7 +737,7 @@
737 737  
738 738  Supported Series: Siemens S7-300 series PLC
739 739  
740 -**1)V-BOX setting**
438 +**1)PLC Setting**
741 741  
742 742  |**Items**|**Settings**|**Note**
743 743  |Protocol|Simens S7-300 Ethernet|
... ... @@ -799,7 +799,7 @@
799 799  
800 800  Supported Series: Siemens S7-400, S7-1200 and S7-1500
801 801  
802 -**1)V-BOX setting**
500 +**1)PLC Setting**
803 803  
804 804  |=**Items**|=**Settings**|=**Note**
805 805  |Protocol|Siemens S7-XXX|
... ... @@ -909,99 +909,9 @@
909 909  
910 910  [[image:image-20220824162342-2.png]]
911 911  
912 -== **LOGO Ethernet Protocol** ==
913 913  
914 -Supported Series: Siemens Logo 0BA0, 0BA1 series
611 += **Mitsubishi PLC** =
915 915  
916 -**V-BOX Settings**
917 -
918 -
919 -|**Items**|**Settings**|**Note**
920 -|Protocol|Siemens LOGO|
921 -|Connection|Ethernet|
922 -|Port No.|102|
923 -|PLC station No.|2|
924 -
925 -**Address List**
926 -
927 -
928 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
929 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
930 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
931 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
932 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
933 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
934 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
935 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
936 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
937 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
938 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
939 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
940 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
941 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
942 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
943 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
944 -
945 -**PLC Settings in LOGO Software:**
946 -
947 -Click [Tools]~-~-[Ethernet Connections],shown as below.
948 -
949 -(% style="text-align:center" %)
950 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
951 -
952 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
953 -
954 -(% style="text-align:center" %)
955 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
956 -
957 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
958 -
959 -(% style="text-align:center" %)
960 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
961 -
962 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
963 -
964 -(% style="text-align:center" %)
965 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
966 -
967 -**V-BOX Communication Settings**
968 -
969 -Set PLC IP in [IP Address] settings;
970 -
971 -(% style="text-align:center" %)
972 -[[image:LldwDGntf4.png]]
973 -
974 -Enable V-BOX Ethernet in [Network];
975 -
976 -(% style="text-align:center" %)
977 -[[image:WgvjfWbQif.png]]
978 -
979 -TSAP setting
980 -
981 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
982 -
983 -{{code language="LUA"}}
984 -function init.main()
985 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
986 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
987 -end
988 -{{/code}}
989 -
990 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
991 -
992 -**✎Note:**
993 -
994 -* **Communication port configuration: **
995 -** Continuous length needs to be set to 0.
996 -** Integration interval needs to be set to 1. (no change may result in data errors)
997 -** Set Port and Device Station NO.
998 -** Other set as defaulted.
999 -* **Notes on the use of registers:**
1000 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
1001 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
1002 -
1003 -= Create communication with **Mitsubishi PLC** =
1004 -
1005 1005  == **FX1S,1N,2N Serial Protocol** ==
1006 1006  
1007 1007  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -1036,248 +1036,27 @@
1036 1036  |S|S|S d|0~~99999|
1037 1037  |SD|SD|SD d|8000~~9999|
1038 1038  
1039 -**3)Configure the communication protocol**
647 +**3)Cable Wiring**
1040 1040  
1041 -[[image:image-20220825102844-3.png]]
1042 -
1043 -**4)Cable Wiring**
1044 -
1045 1045  * **RS422**
1046 1046  
1047 -[[image:image-20220825103350-4.png]]
651 +[[image:image-20220825100814-3.png]]
1048 1048  
1049 1049  [[image:image-20220825100845-4.png]]
1050 1050  
655 +
1051 1051  
1052 -== **FX3U,3G,3GA Serial Protocol** ==
657 +== **FX3U Serial Protocol** ==
1053 1053  
1054 -Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
1055 1055  
1056 -**1)V-BOX Settings**
1057 -
1058 -|**Item**|**Settings**|**Note**
1059 -|Protocol|Mitsubishi FX3U/3G/3GA|
1060 -|Connection|RS422/RS485/RS232|
1061 -|Baud rate|9600~~115200|
1062 -|Data bit|7/8|
1063 -|Parity|EVEN/Odd/None|
1064 -|Stop bit|1/2|
1065 -|PLC station No.|1~~255|
1066 -
1067 -**2)Address List**
1068 -
1069 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1070 -|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
1071 -|Y|Y|Y o|0~~303237|
1072 -|M|M|M d|0~~99999|
1073 -|T|T|T d|0~~99999|
1074 -|C|C|C d|0~~99999|
1075 -|S|S|S d|0~~99999|
1076 -|SM|SM|SM d|8000~~9999|
1077 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
1078 -|Y|Y|Y o|0~~303237|
1079 -|M|M|M d|0~~99999|
1080 -|T|T|T d|0~~99999|
1081 -|C|C|C d|0~~199|
1082 -|D|D|D d|0~~7999|
1083 -|S|S|S d|0~~99999|
1084 -|SD|SD|SD d|8000~~9999|
1085 -
1086 -**3)Configure the communication protocol**
1087 -
1088 -[[image:image-20220825102649-2.png]]
1089 -
1090 -**4)Cable Wiring**
1091 -
1092 -* **RS422**
1093 -
1094 -[[image:image-20220825103421-5.png]]
1095 -
1096 -[[image:image-20220825100845-4.png]]
1097 -
1098 -
1099 -== **FX3U Ethernet Protocol** ==
1100 -
1101 -Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
1102 -
1103 -**1)V-BOX Settings**
1104 -
1105 -|Items|Settings|Note
1106 -|Protocol|Mitsubishi FX3U|
1107 -|Connection|Ethernet|
1108 -|Port No.|5009|Must be the same as the PLC setting
1109 -|PLC station No.|0|
1110 -
1111 -**2)Address List**
1112 -
1113 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1114 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
1115 -|Y|Y|Y OOO|0~~377|
1116 -|M|M|M DDDD|0~~7679|
1117 -|SM|SM|SM DDDD|8000~~8511|
1118 -|S|S|S DDDD|0~~4095|
1119 -|TS|TS|TS DDD|0~~511|
1120 -|CS|CS|CS DDD|0~~255|
1121 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
1122 -|TN|TN|TN DDD|0~~511|
1123 -|D|D|D DDDD|0~~7999|
1124 -|SD|SD|SD DDDD|8000~~8511|
1125 -|R|R|R DDDDD|0~~32767|
1126 -
1127 -**3)Ethernet Module Settings**
1128 -
1129 -FX3U-ENET-L module configuration
1130 -Set up the FX3U-ENET-L Ethernet module settings as follows.
1131 -Select the module location, which in this document is Module 0.
1132 -
1133 -[[image:image-20221116105850-1.png]]
1134 -
1135 -Select "Operational setting" to enter the following screen.
1136 -
1137 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
1138 -
1139 -[[image:image-20221116105947-1.png]]
1140 -
1141 -Select "Open setting" to enter the setting interface, the settings are as follows.
1142 -
1143 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
1144 -
1145 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
1146 -
1147 -[[image:image-20221116110802-1.png]]
1148 -
1149 -Click on "transter setup" - "PC side I/F setting", see the following figure.
1150 -
1151 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
1152 -
1153 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
1154 -
1155 -[[image:image-20221116110832-2.png||height="423" width="708"]]
1156 -
1157 -Read and write data from the Ethernet module
1158 -
1159 -[[image:image-20221116110907-3.png]]
1160 -
1161 -Set "Transter setup" to COM communication, and read or write operation as shown below
1162 -
1163 -[[image:image-20221116110917-4.png]]
1164 -
1165 -**4)PLC Settings (GX Works 2)**
1166 -
1167 -Create a blank FX5U project
1168 -
1169 -Find Current Connection in the navigation
1170 -
1171 -[[image:image-20221116111427-1.png||height="421" width="705"]]
1172 -
1173 -Select Connection Channel List
1174 -
1175 -Select Ethernet board communication
1176 -
1177 -[[image:image-20221116111451-2.png||height="421" width="705"]]
1178 -
1179 -Select Ethernet Module
1180 -Set the IP address of the PLC
1181 -
1182 -[[image:image-20221116111509-3.png||height="666" width="699"]]
1183 -
1184 -Read or write PLC data, in this document is read
1185 -
1186 -[[image:image-20221116111651-4.png||height="416" width="697"]]
1187 -
1188 -[[image:image-20221116111727-5.png||height="416" width="697"]]
1189 -
1190 -**4)Configure the communication protocol**
1191 -
1192 -[[image:image-20221119101946-2.png||height="395" width="695"]]
1193 -
1194 1194  == **FX5U Serial Protocol** ==
1195 1195  
1196 -Mitsubishi FX5U series PLC
1197 1197  
1198 -**1)V-BOX Settings**
1199 -
1200 -|**Item**|**Settings**|**Note**
1201 -|Protocol|Mitsubishi FX5U|
1202 -|Connection|RS422/RS485|
1203 -|Baud rate|9600|
1204 -|Data bit|7|
1205 -|Parity|Odd|
1206 -|Stop bit|1|
1207 -|PLC station No.|1~~255|Need to be the same as PLC settings
1208 -
1209 -**2)Address List**
1210 -
1211 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1212 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
1213 -|Y|Y|Y o|0~~303237|
1214 -|M|M|M d|0~~99999|
1215 -|B|B|B h|0~~7FFF|
1216 -|F|F|F d|0~~32767|
1217 -|SB|SB|SB h|0~~7FFF|
1218 -|TS|TS|TS d|0~~1023|
1219 -|TC|TC|TC d|0~~1023|
1220 -|STS|STS|STS d|0~~1023|
1221 -|STC|STC|STS d|0~~1023|
1222 -|CS|CS|CS d|0~~1023|
1223 -|CC|CC|CC d|0~~1023|
1224 -|SM|SM|SM d|0~~9999|
1225 -|L|L|L d|0~~32767|
1226 -|S|S|S d|0~~4095|
1227 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
1228 -|TN|TN|TN d|0~~1023|
1229 -|STN|STN|STN d|0~~1023|
1230 -|CN|CN|CN d|0~~1023|
1231 -|R|R|R d|0~~32767|
1232 -|SW|SW|SW h|0~~7FFF|
1233 -|Z|Z|Z d|0~~23|
1234 -|D|D|D d|0~~7999|
1235 -|SD|SD|SD d|0~~11999|
1236 -
1237 -**3)PLC Settings (GX Works 3)**
1238 -
1239 -Create a blank FX5U project
1240 -
1241 -Find the 485 serial port module in the system navigation bar and double click to enter the settings.
1242 -
1243 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
1244 -
1245 -Select protocol in the setting item, and set parameters.
1246 -
1247 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
1248 -
1249 -Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
1250 -
1251 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
1252 -
1253 -Click the [Apply] button to finish the setting.
1254 -
1255 -Click download and select the items as below, then click [execute] to download the configuration to PLC.
1256 -
1257 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
1258 -
1259 - As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
1260 -
1261 -Done.
1262 -
1263 -**4)Configure the communication protocol**
1264 -
1265 -[[image:image-20220825104904-1.png]]
1266 -
1267 -**5)Cable Wiring**
1268 -
1269 -
1270 -* **RS422**
1271 -
1272 -[[image:image-20220825105105-2.png]]
1273 -
1274 -[[image:image-20220825105533-3.png]]
1275 -
1276 1276  == **FX5U Ethernet Protocol** ==
1277 1277  
1278 1278  Mitsubishi FX5U series PLC
1279 1279  
1280 -**1)V-BOX Settings**
667 +**HMI Settings**
1281 1281  
1282 1282  |**Items**|**Settings**|**Note**
1283 1283  |Protocol|Mitsubishi FX5U|
... ... @@ -1285,7 +1285,7 @@
1285 1285  |Port No.|5002|Must be the same as the PLC setting
1286 1286  |PLC station No.|0|
1287 1287  
1288 -**2)Address List**
675 +**Address List**
1289 1289  
1290 1290  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1291 1291  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
... ... @@ -1313,11 +1313,12 @@
1313 1313  |D|D|D d|0~~7999|
1314 1314  |SD|SD|SD d|0~~11999|
1315 1315  
1316 -**3)PLC Settings (GX Works 3)**
703 +**PLC Settings (GX Works 3)**
1317 1317  
1318 1318  Find the [Ethernet port] in the navigation area.
1319 1319  
1320 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
707 +(% style="text-align:center" %)
708 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
1321 1321  
1322 1322  Select [Own Node Settings] in the [Setting Item List];
1323 1323  
... ... @@ -1325,7 +1325,8 @@
1325 1325  
1326 1326  Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
1327 1327  
1328 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
716 +(% style="text-align:center" %)
717 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
1329 1329  
1330 1330  Select [SLMP Connection Module] and add into host station as below picture shows;
1331 1331  
... ... @@ -1333,951 +1333,65 @@
1333 1333  
1334 1334  Click [Close with Reflecting the Setting] to save and close window;
1335 1335  
1336 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
725 +(% style="text-align:center" %)
726 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
1337 1337  
1338 1338  Click [Apply] to completed Etherenet settings;
1339 1339  
1340 1340  Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
1341 1341  
1342 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
1343 -
1344 -**4)Configure the communication protocol**
1345 -
1346 -[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
1347 -
1348 -**5)Cable Wiring**
1349 -
1350 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1351 -
1352 -== **L02 Serial Protocol** ==
1353 -
1354 -Mitsubishi L02 series CPU built-in serial port.
1355 -
1356 -**1)V-BOX Settings**
1357 -
1358 -|**Item**|**Settings**|**Note**
1359 -|Protocol|Mitsubishi L02|
1360 -|Connection|RS422|
1361 -|Baud rate|115200|
1362 -|Data bit|8|
1363 -|Parity|Odd|
1364 -|Stop bit|1|
1365 -|PLC station No.|1~~255|Need to be the same as PLC settings
1366 -
1367 -**2)Address List**
1368 -
1369 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1370 -|Bit|X|X|X h|0~~FFFF|
1371 -|Bit|Y|Y|Y h|0~~FFFF|
1372 -|Bit|M|M|M d|0~~9999|
1373 -|Bit|L|L|L d|0~~9999|
1374 -|Bit|F|F|F d|0~~9999|
1375 -|Bit|B|B|B h|0~~FFFF|
1376 -|Bit|V|V|V d|0~~2047|
1377 -|Bit|TC|TC|TC d|0~~9999|
1378 -|Bit|SS|SS|SS d|0~~9999|
1379 -|Bit|SC|SC|SC d|0~~9999|
1380 -|Bit|CS|CS|CS d|0~~9999|
1381 -|Bit|CC|CC|CC d|0~~9999|
1382 -|Bit|SB|SB|SB h|0~~FFFF|
1383 -|Bit|SM|SM|SM d|0~~2047|
1384 -|Bit|STS|STS|STS d|0~~1023|
1385 -|Bit|S|S|S d|0~~9999|
1386 -|Bit|DX|DX|DX h|0~~FFFF|
1387 -|Bit|DY|DY|DY h|0~~FFFF|
1388 -|Bit|TS|TS|TS d|0~~9999|
1389 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
1390 -|Word|W|W|W h|0~~FFFF|
1391 -|Word|TN|TN|TN d|0~~99999|
1392 -|Word|SN|SN|SN d|0~~99999|
1393 -|Word|CN|CN|CN d|0~~99999|
1394 -|Word|R|R|R d|0~~99999|
1395 -|Word|SW|SW|SW h|0~~FFFF|
1396 -|Word|Z|Z|Z d|0~~99999|
1397 -|Word|ZR|ZR|ZR h|0~~FFFF|
1398 -|Word|D|D|D d|0~~99999|
1399 -
1400 -**3)Communication Settings**
1401 -
1402 -[[image:image-20220825160648-3.png]]
1403 -
1404 -**4)Cable Wiring**
1405 -
1406 -* **RS422**
1407 -
1408 -[[image:image-20220825161612-8.png]]
1409 -
1410 -[[image:image-20220825160820-4.png]]
1411 -
1412 -== **L02 Ethernet Protocol** ==
1413 -
1414 -Mitsubishi L series CPU built-in Ethernet port.
1415 -
1416 -**1)V-BOX Settings**
1417 -
1418 -|**Items**|**Settings**|**Note**
1419 -|Protocol|MIT L02 CPU MELSEC|
1420 -|Connection|Ethernet|
1421 -|Port No.|1025|Must be the same as the PLC setting
1422 -|PLC station No.|0|Must be the same as the PLC setting
1423 -
1424 -**2)Address List**
1425 -
1426 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1427 -|Bit|X|X|X h|0~~FFFF|
1428 -|Bit|Y|Y|Y h|0~~FFFF|
1429 -|Bit|M|M|M d|0~~9999|
1430 -|Bit|L|L|L d|0~~9999|
1431 -|Bit|F|F|F d|0~~9999|
1432 -|Bit|B|B|B h|0~~FFFF|
1433 -|Bit|V|V|V d|0~~2047|
1434 -|Bit|TC|TC|TC d|0~~9999|
1435 -|Bit|SS|SS|SS d|0~~9999|
1436 -|Bit|SC|SC|SC d|0~~9999|
1437 -|Bit|CS|CS|CS d|0~~9999|
1438 -|Bit|CC|CC|CC d|0~~9999|
1439 -|Bit|SB|SB|SB h|0~~FFFF|
1440 -|Bit|SM|SM|SM d|0~~2047|
1441 -|Bit|STS|STS|STS d|0~~1023|
1442 -|Bit|S|S|S d|0~~9999|
1443 -|Bit|DX|DX|DX h|0~~FFFF|
1444 -|Bit|DY|DY|DY h|0~~FFFF|
1445 -|Bit|TS|TS|TS d|0~~9999|
1446 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
1447 -|Word|W|W|W h|0~~FFFF|
1448 -|Word|TN|TN|TN d|0~~99999|
1449 -|Word|SN|SN|SN d|0~~99999|
1450 -|Word|CN|CN|CN d|0~~99999|
1451 -|Word|R|R|R d|0~~99999|
1452 -|Word|SW|SW|SW h|0~~FFFF|
1453 -|Word|Z|Z|Z d|0~~99999|
1454 -|Word|ZR|ZR|ZR h|0~~FFFF|
1455 -|Word|D|D|D d|0~~99999|
1456 -
1457 -**3)PLC Settings (GX Works2 )**
1458 -
1459 -Create a project
1460 -
1461 -Set PLC IP, subnet mask and gateway;
1462 -
1463 -Select [Binary Code] as communication data code;
1464 -
1465 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
1466 -
1467 -Set PLC port number, for example 1025
1468 -
1469 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
1470 -
1471 -Save settings;
1472 -
1473 -Download project into PLC device;
1474 -
1475 -Restart PLC device;
1476 -
1477 -**4)Configure the communication protocol**
1478 -
1479 -[[image:image-20220825142659-1.png]]
1480 -
1481 -**5)Cable Wiring**
1482 -
1483 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1484 -
1485 -== **Q12H Serial Protocol** ==
1486 -
1487 -This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1488 -
1489 -[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1490 -
1491 -== **QJ71E71 Ethernet Protocol** ==
1492 -
1493 -Mitsubishi QJ71E71 Ethernet communication module;
1494 -
1495 -**1)V-BOX Settings**
1496 -
1497 -|**Items**|**Settings**|**Note**
1498 -|Protocol|MIT QJ71E71 MELSEC|
1499 -|Connection|Ethernet|
1500 -|Port No.|1025|Must be the same as the PLC setting
1501 -|PLC station No.|0|Must be the same as the PLC setting
1502 -
1503 -**2)Address List**
1504 -
1505 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1506 -|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
1507 -|Y|Y|Y h|0~~1FFF|
1508 -|M|M|M d|0~~99999|
1509 -|L|L|L d|0~~8191|
1510 -|F|F|F d|0~~2047|
1511 -|B|B|B h|0~~1FFF|
1512 -|V|V|V d|0~~2047|
1513 -|TS|TS|TS d|0~~2047|
1514 -|TC|TC|TC d|0~~2047|
1515 -|SS|SS|SS d|0~~2047|
1516 -|SC|SC|SC d|0~~2047|
1517 -|CS|CS|CS d|0~~1023|
1518 -|CC|CC|CC d|0~~1023|
1519 -|SB|SB|SB h|0~~7FF|
1520 -|S|S|S d|0~~8191|
1521 -|DX|DX|DX h|0~~1FFF|
1522 -|DY|DY|DY h|0~~1FFF|
1523 -|SM|SM|SM d|8000~~9999|
1524 -|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
1525 -|D|D|D d|0~~12287|
1526 -|W|W|W h|0~~1FFF|
1527 -|TN|TN|TN d|0~~2047|
1528 -|SN|SN|SN d|0~~2047|
1529 -|CN|CN|CN d|0~~1023|
1530 -|R|R|R d|0~~32767|
1531 -|SW|SW|SW h|0~~7FF|
1532 -|Z|Z|Z d|0~~15|
1533 -|ZR|ZR|ZR h|0~~FE7FF|
1534 -
1535 -**3)PLC Settings(GX Works2)**
1536 -
1537 -* Click [Ethernet/CC IE/MELSECNET];
1538 -* Please select [Ethernet] as network type;
1539 -* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1540 -* Select [Online] as Mode;
1541 -* [[image:image-20221119171343-2.png||height="341" width="587"]]
1542 -* Click [Operation setting] to set IP;
1543 -* Select [Binary Code] as [Communication Data Code];
1544 -* [[image:image-20221119171436-3.png||height="354" width="588"]]
1545 -* Click [Open setting]
1546 -* Set protocol: TCP;
1547 -* Set [unpassive] in [Open system];
1548 -* Set [receive] in [Fixed buffer];
1549 -* Set [procedure Exist] in [Fixed buffer communication];
1550 -* Disable [Pairing open];
1551 -* Set [No confirm] in [Existence confirmation];
1552 -* Host station port number: 5009;
1553 -* Save settings;
1554 -* [[image:image-20221119171611-4.png||height="354" width="588"]]
1555 -* Download project into PLC and restart it
1556 -
1557 -**4)Configure the communication protocol**
1558 -
1559 -[[image:image-20221119171832-5.png||height="354" width="625"]]
1560 -
1561 -
1562 -**5)Cable Wiring**
1563 -
1564 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1565 -
1566 -= Create communication with **Delta PLC** =
1567 -
1568 -== **DVP Ethernet Protocol** ==
1569 -
1570 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1571 -
1572 -**1)V-BOX Settings**
1573 -
1574 -|=**Items**|=**Settings**|=**Note**
1575 -|Protocol|DELTA DVP MODBUS TCP|
1576 -|Connection|Ethernet|
1577 -|Port No.|502|
1578 -|Device No.|1|
1579 -|VBox Device No.|0|
1580 -
1581 -**2)Address List **
1582 -
1583 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1584 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1585 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1586 -|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1587 -|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1588 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1589 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1590 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1591 -|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1592 -|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1593 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1594 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1595 -|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1596 -
1597 -**3) PLC Setting:**
1598 -
1599 -~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1600 -
1601 1601  (% style="text-align:center" %)
1602 -[[image:DVPEthernetWPLSoft2.png]]
733 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
1603 1603  
1604 -2. Set up the communication type and PLC IP:
735 +**Cable Wiring**
1605 1605  
1606 1606  (% style="text-align:center" %)
1607 -[[image:DVPEthernetSetup.png]]
738 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1608 1608  
1609 -(% class="wikigeneratedid" %)
1610 -3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
740 += **Delta PLC** =
1611 1611  
1612 -(% style="text-align:center" %)
1613 -[[image:DVPEthernetTransfer.png]]
742 +== **DVP Ethernet Protocol** ==
1614 1614  
1615 -(% class="wikigeneratedid" %)
1616 -4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
744 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1617 1617  
1618 -(% style="text-align:center" %)
1619 -[[image:DVPEthernetPLCtoPC.png]]
746 +== **DVP Serial Protocol** ==
1620 1620  
1621 -5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
748 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1622 1622  
1623 -(% style="text-align:center" %)
1624 -[[image:DVPEthernetAutoSearch.png]]
750 += **Omron PLC** =
1625 1625  
1626 -**4) V-BOX Setting:**
752 +== **CP1 Series Protocol** ==
1627 1627  
1628 -Set the same IP address according to the setting from WPL Soft:
754 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1629 1629  
1630 -(% style="text-align:center" %)
1631 -[[image:DVPEthernetVNETPortocol.png]]
756 +== **CJ2M Series Protocol** ==
1632 1632  
1633 -== **DVP serial protocol** ==
758 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1634 1634  
1635 -Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
760 += **Modbus RTU** =
1636 1636  
1637 -**1)V-BOX Settings**
762 +== **V-BOX as master** ==
1638 1638  
1639 -|=**Items**|=**Settings**|=**Note**
1640 -|Protocol|DELTA DVP PROTOCOL|
1641 -|Connection|RS232|
1642 -|Baud Rate|9600|
1643 -|Stop Bit|1|
1644 -|Data Bit|7|
1645 -|Parity|EVEN|
1646 -|Device No.|1|
764 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
1647 1647  
1648 -(% class="wikigeneratedid" %)
1649 -**2)Address List**
766 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1650 1650  
1651 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1652 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1653 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1654 -|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1655 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1656 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1657 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1658 -|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1659 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1660 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1661 -|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1662 -
1663 -(% class="wikigeneratedid" %)
1664 -**3)Wiring Diagram**
1665 -
1666 1666  (% style="text-align:center" %)
1667 -[[image:Delta DVP PROTOCOLSerial232.png]]
1668 -
1669 -== **AS Ethernet Protocol** ==
1670 -
1671 -**1)V-BOX Settings**
1672 -
1673 -|=**Items**|=**Settings**|=**Note**
1674 -|Protocol|DELTA AS300 MODBUS TCP|
1675 -|Connection|Ethernet|
1676 -|Port No.|502|
1677 -|Device No.|1|
1678 -|HMI No.|0|
1679 -
1680 -**2)Address List**
1681 -
1682 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1683 -|Bit|X|X|X d|0~~63|
1684 -|Bit|Y|Y|Y d|0~~63|
1685 -|Bit|D|D|D d|0~~29999|
1686 -|Bit|M|M|M d|0~~8191|
1687 -|Bit|SM|SM|SM d|0~~4095|
1688 -|Bit|S|S|S h|0~~2047|
1689 -|Bit|T|T|T d|0~~511|
1690 -|Bit|C|C|C d|0~~511|
1691 -|Bit|HC|HC|HC d|0~~255|
1692 -|Word|X|X|X h|0~~63|
1693 -|Word|Y|Y|Y d|0~~63|
1694 -|Word|SR|SR|SR d|0~~2047|
1695 -|Word|D|D|D d|0~~29999|
1696 -|Word|T|T|T d|0~~511|
1697 -|Word|C|C|C h|0~~511|
1698 -|Word|E|E|E d|0~~9|
1699 -
1700 -**3)Configure the communication protocol**
1701 -
1702 -[[image:image-20220831160010-4.png]]
1703 -
1704 -**4)Cable Wiring**
1705 -
1706 -Figure
1707 -
1708 -[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1709 -
1710 -Pin Definition Diagram
1711 -
1712 -[[image:image-20220831155157-3.png]]
1713 -
1714 -= Create communication with **Omron PLC** =
1715 -
1716 -== **CP1 Series Protocol ** ==
1717 -
1718 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1719 -
1720 -== **CP2M Series Protocol** ==
1721 -
1722 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1723 -
1724 -
1725 -== **EC55 Series Protocol** ==
1726 -
1727 -Supported device: EC55 temperature instrument
1728 -
1729 -**1)V-BOX Settings**
1730 -
1731 -|**Items**|**Settings**|**Note**
1732 -|Protocol|Omron EC55|
1733 -|Connection|RS485 (9600, 2, 7, EVEN)|
1734 -|Port No.|None|
1735 -|PLC station No.|0|
1736 -
1737 -**2)Address List**
1738 -
1739 -|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1740 -|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1741 -|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1742 -|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1743 -|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1744 -|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1745 -|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1746 -|CP|-|0-6|Read controller intrinsic property
1747 -|CS|-|0-2|Read controller states
1748 -|CA|-|0-17|Action command
1749 -
1750 -**3)Device Settings**
1751 -
1752 -Omron E5CC PLC configuration
1753 -
1754 -After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1755 -
1756 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1757 -
1758 -According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1759 -
1760 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1761 -
1762 -**✎Note:** The communication settings for HMI should be consistent with this setting.
1763 -
1764 -**4)Configure the communication protocol**
1765 -
1766 -[[image:image-20220831161041-1.png]]
1767 -
1768 -**5)Cable Wiring**
1769 -
1770 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1771 -
1772 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1773 -
1774 -**✎Note:**
1775 -
1776 -* COM3 only available in PI8000/PI9000 series.
1777 -* CA address could not support continuous writing function;
1778 -* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1779 -* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1780 -* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1781 -* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1782 -* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1783 -* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1784 -* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1785 -
1786 -= Create communication with Xinje** PLC** =
1787 -
1788 -== **XC serial protocol** ==
1789 -
1790 -**1)V-BOX Settings**
1791 -
1792 -|**Item**|**Settings**|**Note**
1793 -|Protocol|XINJE XC MODBUS|
1794 -|Connection|RS232|
1795 -|Baud rate|19200|
1796 -|Data bit|8|
1797 -|Parity|EVEN|
1798 -|Stop bit|1|
1799 -|PLC station No.|1|
1800 -
1801 -**2)Address List**
1802 -
1803 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1804 -|Bit|M|M|M d|0~~8511|
1805 -|Bit|X|X|X o|0~~1747|
1806 -|Bit|Y|Y|Y o|0~~1747|
1807 -|Bit|S|S|S d|0~~1023|
1808 -|Bit|T|T|T d|0~~4095|
1809 -|Bit|C|C|C d|0~~634|
1810 -|Word|D|D|D d|0~~8511|
1811 -|Word|TD|TD|TD d|0~~618|
1812 -|Word|CD|CD|CD d|0~~634|
1813 -|Word|FD|FD|FD d|0~~8511|
1814 -
1815 -**3)Configure the communication protocol**
1816 -
1817 -
1818 -[[image:image-20220831163041-1.png]]
1819 -
1820 -**4)Cable Wiring**
1821 -
1822 -Figure
1823 -
1824 -[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]]
1825 -
1826 -Pin Definition Diagram
1827 -
1828 -[[image:image-20220831163441-4.png]]
1829 -
1830 -== **XD serial protocol** ==
1831 -
1832 -**1)V-BOX Settings**
1833 -
1834 -Supported Series: Xinjie XD/XE Series PLC
1835 -
1836 -|**Item**|**Settings**|**Note**
1837 -|Protocol|XINJE XD/XC MODBUS|
1838 -|Connection|RS232|
1839 -|Baud rate|19200|
1840 -|Data bit|8|
1841 -|Parity|EVEN|
1842 -|Stop bit|1|
1843 -|PLC station No.|1|
1844 -
1845 -**2)Address List**
1846 -
1847 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1848 -|Bit|M|M|M d|0~~74999|
1849 -|Bit|X1xx|X1xx|X1xx o|0~~1177|
1850 -|Bit|X2xx|X2xx|X2xx o|0~~277|
1851 -|Bit|X|X|X o|0~~77|
1852 -|Bit|Y1xx|Y1xx|Y1xx o|0~~1177|
1853 -|Bit|Y2xx|Y2xx|Y2xx o|0~~277|
1854 -|Bit|Y|Y|Y o|0~~4095|
1855 -|Bit|SM|SM|SM d|0~~4999|(((
1856 -
1857 -)))
1858 -|Bit|T|T|T d|0~~4999|
1859 -|Bit|C|C|C d|0~~4999|
1860 -|Bit|ET|ET|ET d|0~~31|
1861 -|Bit|SE|SE|SE d|0~~31|
1862 -|Bit|HM|HM|HM d|0~~11999|
1863 -|Bit|HSC|HSC|HSC d|0~~39|
1864 -|Bit|HS|HS|HS d|0~~999|
1865 -|Bit|HT|HT|HT d|0~~1999|
1866 -|Bit|HC|HC|HC d|0~~1999|
1867 -|Bit|S|S|S d|0~~7999|
1868 -|Word|D|D|D d|0~~69999|
1869 -|Word|ID|ID|ID d|0~~99|
1870 -|Word|ID1xx|ID1xx|ID1xx d|0~~999|
1871 -|Word|ID2xx|ID2xx|ID2xx d|0~~299|
1872 -|Word|QD|QD|QD d|0~~99|
1873 -|Word|QD1xx|QD1xx|QD1xx d|0~~999|
1874 -|Word|QD2xx|QD2xx|QD2xx d|0~~299|
1875 -|Word|SD|SD|SD d|0~~4999|
1876 -|Word|TD|TD|TD d|0~~575|
1877 -|Word|CD|CD|CD d|0~~575|
1878 -|Word|ETD|ETD|ETD d|0~~31|
1879 -|Word|HD|HD|HD d|0~~24999|
1880 -|Word|HSD|HSD|HSD d|0~~1023|
1881 -|Word|HTD|HTD|HTD d|0~~95|
1882 -|Word|HCD|HCD|HCD d|0~~95|
1883 -|Word|HSCD|HSCD|HSCD d|0~~31|
1884 -|Word|FD|FD|FD d|0~~8191|
1885 -|Word|SFD|SFD|SFD d|0~~5999|
1886 -|Word|FS|FS|FS d|0~~47|
1887 -
1888 -**3)Configure the communication protocol**
1889 -
1890 -[[image:image-20220831163923-7.png]]
1891 -
1892 -
1893 -
1894 -**4)Cable Wiring**
1895 -
1896 -Figure
1897 -
1898 -[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]]
1899 -
1900 -Pin Definition Diagram
1901 -
1902 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1903 -
1904 -= Create communication with **Schneider PLC** =
1905 -
1906 -== **Schneider MODBUS RTU** ==
1907 -
1908 -**1)V-BOX Setting**
1909 -
1910 -|=**Parameters**|=**Recommended**|=**Notes**
1911 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1912 -|**Connection**|RS485|
1913 -|**Baud rate**|19200|
1914 -|**Data bit**|8|
1915 -|**Parity**|Even|
1916 -|**Stop bit**|1|
1917 -|**PLC station No.**|1|
1918 -
1919 -**2)Address List**
1920 -
1921 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1922 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1923 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1924 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1925 -|W|MW|DDDDDD|0 ~~ 999999|Output register
1926 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
1927 -
1928 -**3)Configure the communication protocol**
1929 -
1930 -[[image:image-20220902104329-1.png]]
1931 -
1932 -**4)Cable Wiring**
1933 -
1934 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1935 -
1936 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1937 -
1938 -= Create communication with Inovance** PLC** =
1939 -
1940 -== **H3U serial protocol** ==
1941 -
1942 -**1)V-BOX Settings**
1943 -
1944 -|**Item**|**Settings**|**Note**
1945 -|Protocol|INOVANCE H3U PLC|
1946 -|Connection|RS422|
1947 -|Baud rate|9600|
1948 -|Data bit|7|
1949 -|Parity|EVEN|
1950 -|Stop bit|1|
1951 -|PLC station No.|0|
1952 -
1953 -**2)Address List**
1954 -
1955 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1956 -|Bit|X|X|X o|0~~303237|
1957 -|Bit|Y|Y|Y o|0~~303237|
1958 -|Bit|M|M|M d|0~~99999|
1959 -|Bit|T|T|T d|0~~99999|
1960 -|Bit|C|C|C d|0~~99999|
1961 -|Bit|SM|SM|SM d|8000~~999|
1962 -|Bit|S|T|S d|0~~99999|
1963 -|Bit|Lamp|Lamp|Lamp d|0~~0|
1964 -|Word|X|X|X o|0~~303237|
1965 -|Word|Y|Y|Y o|0~~303237|
1966 -|Word|M|M|M d|0~~99999|
1967 -|Word|T|T|T d|0~~99999|
1968 -|Word|C|C|C d|0~~199|
1969 -|Word|D|D|D d|0~~7999|
1970 -|Word|S|S|S d|0~~99999|
1971 -|Word|SD|SD|SD d|8000~~9999|
1972 -|Word|R|R|R d|0~~32767|
1973 -
1974 -**3)Configure the communication protocol**
1975 -
1976 -[[image:image-20220831164626-1.png]]
1977 -
1978 -
1979 -
1980 -**4)Cable Wiring**
1981 -
1982 -Figure
1983 -
1984 -[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1985 -
1986 -Pin Definition Diagram
1987 -
1988 -[[image:image-20220831164731-4.png]]
1989 -
1990 -= Create communication with Panasonic** PLC** =
1991 -
1992 -== **FP serial protocol** ==
1993 -
1994 -**1)V-BOX Settings**
1995 -
1996 -|**Item**|**Settings**|**Note**
1997 -|Protocol|Panasonic FP MFWTOCOL|
1998 -|Connection|RS232|
1999 -|Baud rate|9600|
2000 -|Data bit|8|
2001 -|Parity|ODD|
2002 -|Stop bit|1|
2003 -|PLC station No.|1|
2004 -
2005 -**2)Address List**
2006 -
2007 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
2008 -|Bit|X|X|X d|0~~9999|
2009 -|Bit|Y|Y|Y d|0~~9999|
2010 -|Bit|R|R|R d|0~~9999|
2011 -|Bit|T|T|T d|0~~9999|
2012 -|Bit|C|C|C d|0~~9999|
2013 -|Bit|L|L|L d|0~~9999|
2014 -|Word|WX|WX|WX d|0~~9999|
2015 -|Word|WY|WY|WY d|0~~9999|
2016 -|Word|WR|WR|WR d|0~~9999|
2017 -|Word|WL|WL|WL d|0~~9999|
2018 -|Word|LD|LD|LD d|0~~9999|
2019 -|Word|DT|DT|DT d|0~~65535|
2020 -|Word|FL|FL|FL d|0~~9999|
2021 -|Word|EV|EV|EV d|0~~9999|
2022 -|Word|SV|SV|SV d|0~~9999|
2023 -
2024 -**3)Configure the communication protocol**
2025 -
2026 -[[image:image-20220831165238-4.png]]
2027 -
2028 -
2029 -
2030 -**4)Cable Wiring**
2031 -
2032 -Figure
2033 -
2034 -[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
2035 -
2036 -Pin Definition Diagram
2037 -
2038 -[[image:image-20220831165008-1.png]]
2039 -
2040 -= Create communication with LS** PLC** =
2041 -
2042 -== **XBC serial protocol** ==
2043 -
2044 -**1)V-BOX Settings**
2045 -
2046 -|**Item**|**Settings**|**Note**
2047 -|Protocol|LS XBC CNet|
2048 -|Connection|RS232|
2049 -|Baud rate|115200|
2050 -|Data bit|8|
2051 -|Parity|NONE|
2052 -|Stop bit|1|
2053 -|PLC station No.|1|
2054 -
2055 -**2)Address List**
2056 -
2057 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
2058 -|Bit|P|P|P d|0~~2047|
2059 -|Bit|M|M|M d|0~~2047|
2060 -|Bit|L|L|L d|0~~11263|
2061 -|Bit|K|K|K d|0~~16183|
2062 -|Bit|F|F|F d|0~~2047|
2063 -|Bit|D|D|D d|0~~32767|
2064 -|Bit|R|R|R d|0~~32767|
2065 -|Bit|U|U|U d|0~~4095|
2066 -|Word|P|P|P d|0~~2047|
2067 -|Word|M|M|M d|0~~2047|
2068 -|Word|L|L|L d|0~~11263|
2069 -|Word|K|K|K d|0~~16183|
2070 -|Word|F|F|F d|0~~2047|
2071 -|Word|C|C|C d|0~~2047|
2072 -|Word|T|T|T d|0~~2047|
2073 -|Word|D|D|D d|0~~32767|
2074 -|Word|N|N|N d|0~~21503|
2075 -|Word|R|R|R d|0~~32767|
2076 -|Word|U|U|U d|0~~4095|
2077 -|Word|Z|Z|Z d|0~~127|
2078 -|Word|S|S|S d|0~~127|
2079 -
2080 -**3)Configure the communication protocol**
2081 -
2082 -[[image:image-20220831170147-1.png]]
2083 -
2084 -**4)Cable Wiring**
2085 -
2086 -Figure
2087 -
2088 -[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
2089 -
2090 -Pin Definition Diagram
2091 -
2092 -[[image:image-20220831170215-2.png]]
2093 -
2094 -== **XGK FEnet Ethernet protocol** ==
2095 -
2096 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2097 -
2098 -**1)V-BOX Settings**
2099 -
2100 -|**Items**|**Settings**|**Note**
2101 -|Protocol|LG XGK FEnet(Ethernet)|
2102 -|Connection|Ethernet|
2103 -|Port No.|2004|
2104 -
2105 -**2)Address List**
2106 -
2107 -|**Type**|**Register**|**Range**|**Format**|**Note**
2108 -|(% rowspan="14" %)Word|P|0~~2047|P d|
2109 -|M|0~~2047|M d|
2110 -|K|0~~2047|K d|
2111 -|F|0~~2047|F d|
2112 -|T|0~~2047|T d|
2113 -|C|0~~2047|C d|
2114 -|Z|0~~127|Z d|
2115 -|S|0~~127|S d|
2116 -|L|0~~11263|L d|
2117 -|N|0~~21503|N d|
2118 -|D|0~~32767|D d|
2119 -|R|0~~32767|R d|
2120 -|ZR|0~~65535|ZR d|
2121 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2122 -
2123 -**✎Note:**
2124 -
2125 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2126 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2127 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
2128 -
2129 -**3)Communication Settings**
2130 -
2131 -[[image:image-20220831171127-1.png]]
2132 -
2133 -**4)Cable Wiring**
2134 -
2135 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2136 -
2137 -= Create communication with **Modbus ** =
2138 -
2139 -== **MODBUS RTU Slave (All function)** ==
2140 -
2141 -Select the protocol "Modbus RTU Slave (All Fuction)",
2142 -
2143 -Then set baud rate, port, stop bits, data bits, parity.
2144 -
2145 -(% style="text-align:center" %)
2146 2146  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
2147 2147  
2148 -== **Communicate with Modbus Meter** ==
771 +== **V-BOX as slave** ==
2149 2149  
2150 -The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
773 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
2151 2151  
2152 -~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
775 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
2153 2153  
2154 2154  (% style="text-align:center" %)
2155 -[[image:LinfeeTerminalDiagram.png]]
2156 -
2157 -2. Check the specific Modbus parameter in the communication menu from LED display.
2158 -
2159 -So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2160 -
2161 -{{info}}
2162 -**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2163 -{{/info}}
2164 -
2165 -(% style="text-align:center" %)
2166 -[[image:MeterModbusAllView.png]]
2167 -
2168 -(% class="wikigeneratedid" %)
2169 -3. Set up the communication in the Configuration tab.
2170 -
2171 -(% class="wikigeneratedid" %)
2172 -Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2173 -
2174 -(% style="text-align:center" %)
2175 -[[image:VNETCommunicationtabmeter.png]]
2176 -
2177 -(% class="wikigeneratedid" %)
2178 -4. Create new real-time monitoring tag accroding to Modbus manual
2179 -
2180 -(% class="wikigeneratedid" %)
2181 -Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2182 -
2183 -(% class="wikigeneratedid" %)
2184 -**0x03/0x04 command data register address**:
2185 -
2186 -(% style="width:1142.22px" %)
2187 -|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2188 -|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2189 -|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2190 -|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2191 -|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2192 -|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2193 -|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2194 -|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2195 -|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2196 -|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2197 -|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2198 -|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2199 -|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2200 -|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2201 -
2202 -{{info}}
2203 -**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2204 -{{/info}}
2205 -
2206 -For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2207 -
2208 -(% style="text-align:center" %)
2209 -[[image:VNETModbusTagSettings.png]]
2210 -
2211 -(% style="text-align:center" %)
2212 -[[image:VNETModbusTagByteSettings.png]]
2213 -
2214 -{{info}}
2215 -**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2216 -{{/info}}
2217 -
2218 -Set the Modbus Slave Station No.
2219 -
2220 -(% style="text-align:center" %)
2221 -[[image:ModbusStationSettings.png]]
2222 -
2223 -If the communication is setup successfully, the tag will show green light.
2224 -
2225 -(% style="text-align:center" %)
2226 -[[image:Monitoringtaggreenlight.png]]
2227 -
2228 -== **MODBUS RTU Master** ==
2229 -
2230 -Select the protocol "Modbus RTU Master",
2231 -
2232 -Then set baud rate, port, stop bits, data bits, parity
2233 -
2234 -(% style="text-align:center" %)
2235 2235  [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
2236 2236  
2237 -**address list**
780 +**Address List**
2238 2238  
2239 2239  (% class="table-bordered" %)
2240 -|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
2241 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
2242 -|06 (write single register: write a binary value to a holding register)
2243 -|10 (write values to multiple addresses )
2244 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
2245 -|06 (write single register: write a binary value to a holding register)
2246 -|10 (write values to multiple addresses )
2247 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
2248 -|06 (write single register: write a binary value to a holding register)
2249 -|10 (write values to multiple addresses )
2250 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
2251 -|10 (write values to multiple addresses )
2252 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
2253 -|05 (Force a single coil to force the on/off state of a logic coil)
2254 -|0F (Write multiple bits, ie write continuously)
2255 -|(% rowspan="3" %)1|02 (Read the input state)
2256 -|05 (Force a single coil to force the on/off state of a logic coil)
2257 -|0F (Write multiple bits)
2258 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
2259 -|05 (Force a single coil to force the on/off state of a logic coil)
2260 -|0F (Write multiple bits)
2261 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2262 -|0F (Write multiple bits)
2263 -
2264 -== **MODBUS TCP Slave (All function)** ==
2265 -
2266 -Supported series: MODBUS TCP controller
2267 -
2268 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
2269 -
2270 -**1)V-BOX Setting**
2271 -
2272 -|**Items**|**Settings**|**Note**
2273 -|Protocol|MODBUS TCP Slave (All function)|
2274 -|Connection|Ethernet|
2275 -|Port No.|502|
2276 -|PLC station No.|1
2277 -
2278 -**2)Address List**
2279 -
2280 -|=**Type**|=**Data Type**|=**Function code & Description**
783 +|**Type**|**Register**|**Function code & Description**
2281 2281  |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
2282 2282  |06 (write single register: write a binary value to a holding register)
2283 2283  |10 (write values to multiple addresses )
... ... @@ -2301,21 +2301,6 @@
2301 2301  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2302 2302  |0F (Write multiple bits)
2303 2303  
2304 -**3)Communication Settings**
2305 -
2306 -Configure V-BOX Ethernet IP in Networking Settings
2307 -
2308 -[[image:image-20220902111833-3.png]]
2309 -
2310 -
2311 -Configure PLC Ethernet IP in Communication;
2312 -
2313 -[[image:image-20220902111121-1.png]]
2314 -
2315 -**4)Cable Wiring**
2316 -
2317 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2318 -
2319 2319  == **communicate with VB inverter** ==
2320 2320  
2321 2321  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
0Il1q9GZgk.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
1679563870401-671.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -15.9 KB
Content
AB.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -27.1 KB
Content
ControlStarCommunicate.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -46.3 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -14.9 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.7 KB
Content
Emerson.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -13.7 KB
Content
Ethernet.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -45.5 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.6 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.3 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -12.8 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -26.7 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -35.7 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -36.3 KB
Content
conne ab plc.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -43.1 KB
Content
export.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -115.2 KB
Content
export1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -115.2 KB
Content
image-20220825102641-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -123.2 KB
Content
image-20220825102649-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -123.2 KB
Content
image-20220825102844-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -121.8 KB
Content
image-20220825103350-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -65.9 KB
Content
image-20220825103421-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -66.0 KB
Content
image-20220825104904-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -123.5 KB
Content
image-20220825105105-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -78.5 KB
Content
image-20220825105533-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -23.8 KB
Content
image-20220825112403-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -128.1 KB
Content
image-20220825142437-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.5 KB
Content
image-20220825142659-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -124.2 KB
Content
image-20220825143728-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -124.7 KB
Content
image-20220825160227-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -148.8 KB
Content
image-20220825160341-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -121.7 KB
Content
image-20220825160648-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -122.7 KB
Content
image-20220825160820-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
image-20220825160925-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -31.0 KB
Content
image-20220825160929-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -31.0 KB
Content
image-20220825161440-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -90.7 KB
Content
image-20220825161612-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -86.3 KB
Content
image-20220831155101-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -59.6 KB
Content
image-20220831160055-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -51.5 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.1 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -27.0 KB
Content
image-20220831163041-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.6 KB
Content
image-20220831163406-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831163422-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -53.9 KB
Content
image-20220831163441-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.7 KB
Content
image-20220831163548-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -37.1 KB
Content
image-20220831163553-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -37.1 KB
Content
image-20220831163923-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.3 KB
Content
image-20220831164626-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -69.6 KB
Content
project create.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.5 KB
Content
software.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -13.1 KB
Content