Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,5 @@ 1 -= ** 1 General communicationwith PLC** =1 += **Modbus RTU** = 2 2 3 -== **Modbus RTU** == 4 - 5 5 === **V-BOX as master** === 6 6 7 7 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -85,9 +85,6 @@ 85 85 * **RS485** 86 86 87 87 (% style="text-align:center" %) 88 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 89 - 90 -(% style="text-align:center" %) 91 91 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 92 92 93 93 * **RS422** ... ... @@ -102,8 +102,9 @@ 102 102 103 103 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 104 104 105 -== HMI and Wecon LX5V serial communication == 106 106 101 +== **HMI and Wecon LX5V serial communication** == 102 + 107 107 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 108 108 109 109 **Software configuration of PLC** ... ... @@ -112,6 +112,7 @@ 112 112 113 113 [[image:image-20220810164710-1.png]] 114 114 111 + 115 115 **2)New PLC project** 116 116 117 117 Click New Project and select the PLC model. ... ... @@ -118,6 +118,7 @@ 118 118 119 119 [[image:image-20220810172412-1.png]] 120 120 118 + 121 121 **3)Set Serial port parameters** 122 122 123 123 Follow the steps below to configure Serial port parameters ... ... @@ -132,10 +132,12 @@ 132 132 133 133 [[image:image-20220810165759-3.png]] 134 134 133 + 135 135 **4)Registers list** 136 136 137 137 [[image:image-20220811102219-3.png]] 138 138 138 + 139 139 **HMI software configuration** 140 140 141 141 **1)HMI programming software** ... ... @@ -148,6 +148,7 @@ 148 148 149 149 [[image:image-20220810172010-5.png]] 150 150 151 + 151 151 **3)Set communication port parameters** 152 152 153 153 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -162,6 +162,7 @@ 162 162 163 163 [[image:image-20220811104012-1.png]] 164 164 166 + 165 165 **hardware connection** 166 166 167 167 **1)Hardware wiring diagram** ... ... @@ -168,6 +168,8 @@ 168 168 169 169 This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 170 170 173 + 174 + 171 171 [[image:image-20220811103005-4.png]] 172 172 173 173 [[image:image-20220811103227-7.png]] ... ... @@ -174,7 +174,7 @@ 174 174 175 175 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 176 176 177 -== HMI and Wecon LX5V-N Ethernet communication == 181 +== **HMI and Wecon LX5V-N Ethernet communication** == 178 178 179 179 This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 180 180 ... ... @@ -249,7 +249,7 @@ 249 249 250 250 = **Rockwell PLC** = 251 251 252 -== **Communication with A llen-BradleyCompactLogix L1769** ==256 +== **Communication with AB CompactLogix L1769** == 253 253 254 254 ((( 255 255 ((( ... ... @@ -452,6 +452,14 @@ 452 452 453 453 ((( 454 454 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 459 + 460 + 461 +== **Allen-Bradley Ethernet DF1** == 462 + 463 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 464 + 465 + 466 += **Siemens PLC** = 455 455 ))) 456 456 ))) 457 457 ... ... @@ -459,14 +459,12 @@ 459 459 460 460 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 461 461 462 -== **Allen-Bradley Ethernet DF1** == 463 - 464 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 465 - 466 466 == **Communication with S7-200 Smart** == 467 467 468 468 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 469 469 478 += **Delta PLC** = 479 + 470 470 == **Delta DVP Ethernet** == 471 471 472 472 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content