Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -665,98 +665,7 @@ 665 665 666 666 = Create communication with EMERSON PLC = 667 667 668 -== **RTU Slave Protocol** == 669 669 670 -Supported series: EC10 series 671 - 672 -**1)V-BOX setting** 673 - 674 -|**Items**|**Settings**|**Note** 675 -|Protocol|Emerson 984 RTU Slave MODBUS| 676 -|Connection|RS485| 677 -|Baud rate|19200| 678 -|Data bit|8| 679 -|Parity|EVEN| 680 -|Stop bit|1| 681 -|Device station No.|1|Need to be same as the PLC setting 682 - 683 -(% class="wikigeneratedid" %) 684 -**2)PLC Setting** 685 - 686 -(% class="wikigeneratedid" %) 687 -Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 688 - 689 -(% style="text-align:center" %) 690 -[[image:ControlStarSystemBlock.png]] 691 - 692 -(% style="text-align:center" %) 693 -[[image:ControlStarCommunicate.png]] 694 - 695 -(% style="text-align:center" %) 696 -[[image:ControlStarModbus.png]] 697 - 698 -(% class="wikigeneratedid" %) 699 -**3)Address List** 700 - 701 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 702 -|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 703 -|X|XOOO|0~~377| 704 -|M0|M0DDDD|0~~2047| 705 -|M1|M1DDDDD|2048~~10239| 706 -|SM0|SM0DDD|0~~255| 707 -|SM1|SM1DDD|256~~511| 708 -|S0|S0DDDD|0~~1023| 709 -|S1|S1DDDD|1024~~4095| 710 -|T0|T0DDD|0~~255| 711 -|T1|T1DDD|256~~511| 712 -|C0|C0DDD|0~~255| 713 -|C1|C1DDD|256~~306| 714 -|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 715 -|Z|ZDD|0~~15| 716 -|TW0|TW0DDD|0~~255| 717 -|TW1|TW1DDD|256~~511| 718 -|SD0|SD0DDD|0~~255| 719 -|SD1|SD1DDD|256~~511| 720 -|CW|CWDDD|0~~306| 721 -|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 722 -|CW1|CW1DDDDD|256~~99999| 723 - 724 -**4) Cable Wiring** 725 - 726 -(% style="text-align:center" %) 727 -[[image:Emerson.png]] 728 - 729 -= Create communication with HollySys PLC = 730 - 731 -== **LK Modbus RTU** == 732 - 733 -**1)V-BOX setting** 734 - 735 -|**Items**|**Settings**|**Note** 736 -|Protocol|HollySys LK Modbus RTU| 737 -|Connection|RS485| 738 -|Baud rate|38400| 739 -|Data bit|8| 740 -|Parity|None| 741 -|Stop bit|1| 742 -|Device station No.|1| 743 - 744 -**2)Address List** 745 - 746 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 747 -|Bit|QX|QXDDDDD.dd|0~~65535.15| 748 -|Bit|IX|IXDDDDD.dd|0~~65535.15| 749 -|Bit|MX|MXDDDDD.dd|0~~65535.15| 750 -|Word|QW|QWDDDDD|0~~99999| 751 -|Word|IW|IWDDDDD|0~~99999| 752 -|Word|MW|MWDDDDD|0~~99999| 753 -|Word|MD|MDDDDDD|0~~99999| 754 - 755 -**3)Cable Wiring** 756 - 757 -(% style="text-align:center" %) 758 -[[image:Hollysys485-2.png]] 759 - 760 760 = Create communication with **Siemens PLC** = 761 761 762 762 == **S7-200 Smart Ethernet Protocol** ==
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.7 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.4 KB - Content