Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,8 +2,6 @@ 2 2 3 3 == **LX3V Serial Protocol** == 4 4 5 -== **xcvxvxcv** == 6 - 7 7 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 8 8 9 9 **1)V-BOX setting** ... ... @@ -667,100 +667,7 @@ 667 667 668 668 = Create communication with EMERSON PLC = 669 669 670 -== **RTU Slave Protocol** == 671 671 672 -Supported series: EC10 series 673 - 674 -**1)V-BOX setting** 675 - 676 -|**Items**|**Settings**|**Note** 677 -|Protocol|Emerson 984 RTU Slave MODBUS| 678 -|Connection|RS485| 679 -|Baud rate|19200| 680 -|Data bit|8| 681 -|Parity|EVEN| 682 -|Stop bit|1| 683 -|Device station No.|1|Need to be same as the PLC setting 684 - 685 -(% class="wikigeneratedid" %) 686 -**2)PLC Setting** 687 - 688 -(% class="wikigeneratedid" %) 689 -Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 690 - 691 -(% style="text-align:center" %) 692 -[[image:ControlStarSystemBlock.png]] 693 - 694 -(% style="text-align:center" %) 695 -[[image:ControlStarCommunicate.png]] 696 - 697 -(% style="text-align:center" %) 698 -[[image:ControlStarModbus.png]] 699 - 700 -(% class="wikigeneratedid" %) 701 -**3)Address List** 702 - 703 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 704 -|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 705 -|X|XOOO|0~~377| 706 -|M0|M0DDDD|0~~2047| 707 -|M1|M1DDDDD|2048~~10239| 708 -|SM0|SM0DDD|0~~255| 709 -|SM1|SM1DDD|256~~511| 710 -|S0|S0DDDD|0~~1023| 711 -|S1|S1DDDD|1024~~4095| 712 -|T0|T0DDD|0~~255| 713 -|T1|T1DDD|256~~511| 714 -|C0|C0DDD|0~~255| 715 -|C1|C1DDD|256~~306| 716 -|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 717 -|Z|ZDD|0~~15| 718 -|TW0|TW0DDD|0~~255| 719 -|TW1|TW1DDD|256~~511| 720 -|SD0|SD0DDD|0~~255| 721 -|SD1|SD1DDD|256~~511| 722 -|CW|CWDDD|0~~306| 723 -|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 724 -|CW1|CW1DDDDD|256~~99999| 725 - 726 -**4) Cable Wiring** 727 - 728 -(% style="text-align:center" %) 729 -[[image:Emerson.png]] 730 - 731 -= Create communication with HollySys PLC = 732 - 733 -== **LK Modbus RTU** == 734 - 735 -Supported Series: HollySys LK series PLC 736 - 737 -**1)V-BOX setting** 738 - 739 -|**Items**|**Settings**|**Note** 740 -|Protocol|HollySys LK Modbus RTU| 741 -|Connection|RS485| 742 -|Baud rate|38400| 743 -|Data bit|8| 744 -|Parity|None| 745 -|Stop bit|1| 746 -|Device station No.|1| 747 - 748 -**2)Address List** 749 - 750 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 751 -|Bit|QX|QXDDDDD.dd|0~~65535.15| 752 -|Bit|IX|IXDDDDD.dd|0~~65535.15| 753 -|Bit|MX|MXDDDDD.dd|0~~65535.15| 754 -|Word|QW|QWDDDDD|0~~99999| 755 -|Word|IW|IWDDDDD|0~~99999| 756 -|Word|MW|MWDDDDD|0~~99999| 757 -|Word|MD|MDDDDDD|0~~99999| 758 - 759 -**3)Cable Wiring** 760 - 761 -(% style="text-align:center" %) 762 -[[image:Hollysys485-2.png]] 763 - 764 764 = Create communication with **Siemens PLC** = 765 765 766 766 == **S7-200 Smart Ethernet Protocol** ==
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.7 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.4 KB - Content