... ... @@ -2,8 +2,6 @@
2 2  
3 3  == **LX3V Serial Protocol** ==
4 4  
5 -== **xcvxvxcv** ==
6 -
7 7  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
8 8  
9 9  **1)V-BOX setting**
... ... @@ -667,7 +667,7 @@
667 667  
668 668  = Create communication with EMERSON PLC =
669 669  
670 -== **RTU Slave Protocol** ==
668 += **RTU Slave Protocol** =
671 671  
672 672  Supported series: EC10 series
673 673  
... ... @@ -761,6 +761,44 @@
761 761  (% style="text-align:center" %)
762 762  [[image:Hollysys485-2.png]]
763 763  
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +
764 764  = Create communication with **Siemens PLC** =
765 765  
766 766  == **S7-200 Smart Ethernet Protocol** ==
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content