Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 246.1
edited by Hunter
on 2023/07/05 11:37
on 2023/07/05 11:37
Change comment:
There is no comment for this version
To version 248.1
edited by Theodore Xu
on 2023/07/10 11:07
on 2023/07/10 11:07
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.AiXia - Content
-
... ... @@ -1,3 +1,5 @@ 1 += Create communication with INVT = 2 + 1 1 = Create communication with WECON PLC = 2 2 3 3 == **LX3V Serial Protocol** == ... ... @@ -759,6 +759,46 @@ 759 759 (% style="text-align:center" %) 760 760 [[image:Hollysys485-2.png]] 761 761 764 +== **LM Modbus RTU** == 765 + 766 +(% class="wikigeneratedid" %) 767 +Supported Series: HollySys LM3109/LM3107 PLC 768 + 769 +(% class="wikigeneratedid" %) 770 +**1)V-BOX setting** 771 + 772 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note** 773 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %) 774 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %) 775 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %) 776 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %) 777 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %) 778 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 779 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 780 + 781 +**2)Address List** 782 + 783 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 784 +|Bit|QX|QXDDDDD.o|0~~99999.7| 785 +|Bit|IX|IXDDDDD.o|0~~99999.7| 786 +|Bit|MX|MXDDDDD.o|0~~99999.7| 787 +|Word|QW|QWDDDDD|0~~99999| 788 +|Word|IW|IWDDDDD|0~~99999| 789 +|Word|MW|MWDDDDD|0~~99999| 790 +|Word|MD|MDDDDDD|0~~99999| 791 + 792 +**Cable Wiring** 793 + 794 +RS232 795 + 796 +(% style="text-align:center" %) 797 +[[image:HollySysRS232.png]] 798 + 799 +RS485 800 + 801 +(% style="text-align:center" %) 802 +[[image:Hollysys LM Modbus RTU.gif]] 803 + 762 762 = Create communication with **Siemens PLC** = 763 763 764 764 == **S7-200 Smart Ethernet Protocol** ==
- HollySysRS232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- Hollysys LM Modbus RTU.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content