Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 246.2
edited by Hunter
on 2023/07/05 12:02
Change comment: There is no comment for this version
To version 240.1
edited by Hunter
on 2023/05/19 18:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -665,7 +665,7 @@
665 665  
666 666  = Create communication with EMERSON PLC =
667 667  
668 -= **RTU Slave Protocol** =
668 +== **RTU Slave Protocol** ==
669 669  
670 670  Supported series: EC10 series
671 671  
... ... @@ -730,8 +730,6 @@
730 730  
731 731  == **LK Modbus RTU** ==
732 732  
733 -Supported Series: HollySys LK series PLC
734 -
735 735  **1)V-BOX setting**
736 736  
737 737  |**Items**|**Settings**|**Note**
... ... @@ -759,44 +759,6 @@
759 759  (% style="text-align:center" %)
760 760  [[image:Hollysys485-2.png]]
761 761  
762 -== **LM Modbus RTU** ==
763 -
764 -(% class="wikigeneratedid" %)
765 -Supported Series: HollySys LM3109/LM3107 PLC
766 -
767 -(% class="wikigeneratedid" %)
768 -**1)V-BOX setting**
769 -
770 -|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 -|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 -|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 -|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 -|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 -|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 -|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 -|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 -
779 -**2)Address List**
780 -
781 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 -|Bit|QX|QXDDDDD.o|0~~99999.7|
783 -|Bit|IX|IXDDDDD.o|0~~99999.7|
784 -|Bit|MX|MXDDDDD.o|0~~99999.7|
785 -|Word|QW|QWDDDDD|0~~99999|
786 -|Word|IW|IWDDDDD|0~~99999|
787 -|Word|MW|MWDDDDD|0~~99999|
788 -|Word|MD|MDDDDDD|0~~99999|
789 -
790 -**Cable Wiring**
791 -
792 -RS232
793 -
794 -(% style="text-align:center" %)
795 -[[image:HollySysRS232.png]]
796 -
797 -RS485
798 -
799 -
800 800  = Create communication with **Siemens PLC** =
801 801  
802 802  == **S7-200 Smart Ethernet Protocol** ==
HollySysRS232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.4 KB
Content