Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 246.2
edited by Hunter
on 2023/07/05 12:02
Change comment: There is no comment for this version
To version 257.1
edited by Theodore Xu
on 2023/08/23 19:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -1,6 +1,6 @@
1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -277,7 +277,7 @@
277 277  (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 278  (% id="cke_bm_5621S" style="display:none" %)** **
279 279  
280 -== **MicroLogix Protocol** ==
280 +== **MicroLogix Serial** ==
281 281  
282 282  (% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -317,7 +317,7 @@
317 317  
318 318  [[image:image-20220824110724-1.png]]
319 319  
320 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
321 321  
322 322  (((
323 323  (((
... ... @@ -520,7 +520,7 @@
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 522  
523 -== **Micro850_FreeTag Protocol(new)** ==
523 +== **Micro850_FreeTag Ethernet(new)** ==
524 524  
525 525  This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 526  
... ... @@ -663,9 +663,9 @@
663 663  **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 664  {{/info}}
665 665  
666 -= Create communication with EMERSON PLC =
666 += EMERSON =
667 667  
668 -= **RTU Slave Protocol** =
668 += **RTU Slave ** =
669 669  
670 670  Supported series: EC10 series
671 671  
... ... @@ -726,9 +726,9 @@
726 726  (% style="text-align:center" %)
727 727  [[image:Emerson.png]]
728 728  
729 -= Create communication with HollySys PLC =
729 += HollySys PLC =
730 730  
731 -== **LK Modbus RTU** ==
731 +== **LK Modbus RTU ** ==
732 732  
733 733  Supported Series: HollySys LK series PLC
734 734  
... ... @@ -796,16 +796,17 @@
796 796  
797 797  RS485
798 798  
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
799 799  
800 -= Create communication with **Siemens PLC** =
802 += **Siemens ** =
801 801  
802 -== **S7-200 Smart Ethernet Protocol** ==
804 +== **S7-200 Smart Ethernet ** ==
803 803  
804 804  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
805 805  
808 +== **S7-300 Ethernet ** ==
806 806  
807 -== **S7-300 Ethernet Protocol** ==
808 -
809 809  Supported Series: Siemens S7-300 series PLC
810 810  
811 811  **1)V-BOX setting**
... ... @@ -862,11 +862,11 @@
862 862  )))
863 863  )))
864 864  
865 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
866 866  
867 867  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
868 868  
869 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
870 870  
871 871  Supported Series: Siemens S7-400, S7-1200 and S7-1500
872 872  
... ... @@ -980,7 +980,7 @@
980 980  
981 981  [[image:image-20220824162342-2.png]]
982 982  
983 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
984 984  
985 985  Supported Series: Siemens Logo 0BA0, 0BA1 series
986 986  
... ... @@ -1071,9 +1071,9 @@
1071 1071  ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
1072 1072  ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
1073 1073  
1074 -= Create communication with **Mitsubishi PLC** =
1075 += **Mitsubishi ** =
1075 1075  
1076 -== **FX1S,1N,2N Serial Protocol** ==
1077 +== **FX1S,1N,2N Serial ** ==
1077 1077  
1078 1078  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
1079 1079  
... ... @@ -1120,7 +1120,7 @@
1120 1120  [[image:image-20220825100845-4.png]]
1121 1121  
1122 1122  
1123 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
1124 1124  
1125 1125  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
1126 1126  
... ... @@ -1167,7 +1167,7 @@
1167 1167  [[image:image-20220825100845-4.png]]
1168 1168  
1169 1169  
1170 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
1171 1171  
1172 1172  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
1173 1173  
... ... @@ -1262,7 +1262,7 @@
1262 1262  
1263 1263  [[image:image-20221119101946-2.png||height="395" width="695"]]
1264 1264  
1265 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
1266 1266  
1267 1267  Mitsubishi FX5U series PLC
1268 1268  
... ... @@ -1344,7 +1344,7 @@
1344 1344  
1345 1345  [[image:image-20220825105533-3.png]]
1346 1346  
1347 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
1348 1348  
1349 1349  Mitsubishi FX5U series PLC
1350 1350  
... ... @@ -1420,7 +1420,7 @@
1420 1420  
1421 1421  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1422 1422  
1423 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1424 1424  
1425 1425  Mitsubishi L02 series CPU built-in serial port.
1426 1426  
... ... @@ -1480,7 +1480,7 @@
1480 1480  
1481 1481  [[image:image-20220825160820-4.png]]
1482 1482  
1483 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1484 1484  
1485 1485  Mitsubishi L series CPU built-in Ethernet port.
1486 1486  
... ... @@ -1553,13 +1553,13 @@
1553 1553  
1554 1554  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1555 1555  
1556 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1557 1557  
1558 1558  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1559 1559  
1560 1560  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1561 1561  
1562 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1563 1563  
1564 1564  Mitsubishi QJ71E71 Ethernet communication module;
1565 1565  
... ... @@ -1634,9 +1634,9 @@
1634 1634  
1635 1635  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1636 1636  
1637 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1638 1638  
1639 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1640 1640  
1641 1641  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1642 1642  
... ... @@ -1701,7 +1701,7 @@
1701 1701  (% style="text-align:center" %)
1702 1702  [[image:DVPEthernetVNETPortocol.png]]
1703 1703  
1704 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1705 1705  
1706 1706  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1707 1707  
... ... @@ -1737,7 +1737,7 @@
1737 1737  (% style="text-align:center" %)
1738 1738  [[image:Delta DVP PROTOCOLSerial232.png]]
1739 1739  
1740 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1741 1741  
1742 1742  **1)V-BOX Settings**
1743 1743  
... ... @@ -1782,19 +1782,18 @@
1782 1782  
1783 1783  [[image:image-20220831155157-3.png]]
1784 1784  
1785 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1786 1786  
1787 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1788 1788  
1789 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 1790  
1791 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1792 1792  
1793 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 1794  
1796 +== **EC55 Series ** ==
1795 1795  
1796 -== **EC55 Series Protocol** ==
1797 -
1798 1798  Supported device: EC55 temperature instrument
1799 1799  
1800 1800  **1)V-BOX Settings**
... ... @@ -1854,9 +1854,9 @@
1854 1854  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1855 1855  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1856 1856  
1857 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1858 1858  
1859 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1860 1860  
1861 1861  **1)V-BOX Settings**
1862 1862  
... ... @@ -1898,7 +1898,7 @@
1898 1898  
1899 1899  [[image:image-20220831163441-4.png]]
1900 1900  
1901 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1902 1902  
1903 1903  **1)V-BOX Settings**
1904 1904  
... ... @@ -1972,7 +1972,7 @@
1972 1972  
1973 1973  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1974 1974  
1975 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1976 1976  
1977 1977  == **Schneider MODBUS RTU** ==
1978 1978  
... ... @@ -2006,7 +2006,7 @@
2006 2006  
2007 2007  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
2008 2008  
2009 -= Create communication with Inovance** PLC** =
2009 += Inovance =
2010 2010  
2011 2011  == **H3U serial protocol** ==
2012 2012  
... ... @@ -2058,9 +2058,9 @@
2058 2058  
2059 2059  [[image:image-20220831164731-4.png]]
2060 2060  
2061 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
2062 2062  
2063 -== **FP serial protocol** ==
2063 +== **FP serial** ==
2064 2064  
2065 2065  **1)V-BOX Settings**
2066 2066  
... ... @@ -2108,9 +2108,9 @@
2108 2108  
2109 2109  [[image:image-20220831165008-1.png]]
2110 2110  
2111 -= Create communication with LS** PLC** =
2111 += LS =
2112 2112  
2113 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
2114 2114  
2115 2115  **1)V-BOX Settings**
2116 2116  
... ... @@ -2162,7 +2162,7 @@
2162 2162  
2163 2163  [[image:image-20220831170215-2.png]]
2164 2164  
2165 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
2166 2166  
2167 2167  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2168 2168  
... ... @@ -2205,8 +2205,76 @@
2205 2205  
2206 2206  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2207 2207  
2208 -= Create communication with **Modbus ** =
2208 += INVT =
2209 2209  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
2210 2210  == **MODBUS RTU Slave (All function)** ==
2211 2211  
2212 2212  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -2216,7 +2216,7 @@
2216 2216  (% style="text-align:center" %)
2217 2217  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
2218 2218  
2219 -== **Communicate with Modbus Meter** ==
2287 +== **Modbus Meter** ==
2220 2220  
2221 2221  The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2222 2222  
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content