Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 248.1
edited by Theodore Xu
on 2023/07/10 11:07
Change comment: There is no comment for this version
To version 238.1
edited by Hunter
on 2023/05/06 15:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Hunter
Content
... ... @@ -1,5 +3,3 @@
1 -= Create communication with INVT =
2 -
3 3  = Create communication with WECON PLC =
4 4  
5 5  == **LX3V Serial Protocol** ==
... ... @@ -667,7 +667,7 @@
667 667  
668 668  = Create communication with EMERSON PLC =
669 669  
670 -= **RTU Slave Protocol** =
668 +== **RTU Slave Protocol** ==
671 671  
672 672  Supported series: EC10 series
673 673  
... ... @@ -728,79 +728,6 @@
728 728  (% style="text-align:center" %)
729 729  [[image:Emerson.png]]
730 730  
731 -= Create communication with HollySys PLC =
732 -
733 -== **LK Modbus RTU** ==
734 -
735 -Supported Series: HollySys LK series PLC
736 -
737 -**1)V-BOX setting**
738 -
739 -|**Items**|**Settings**|**Note**
740 -|Protocol|HollySys LK Modbus RTU|
741 -|Connection|RS485|
742 -|Baud rate|38400|
743 -|Data bit|8|
744 -|Parity|None|
745 -|Stop bit|1|
746 -|Device station No.|1|
747 -
748 -**2)Address List**
749 -
750 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
751 -|Bit|QX|QXDDDDD.dd|0~~65535.15|
752 -|Bit|IX|IXDDDDD.dd|0~~65535.15|
753 -|Bit|MX|MXDDDDD.dd|0~~65535.15|
754 -|Word|QW|QWDDDDD|0~~99999|
755 -|Word|IW|IWDDDDD|0~~99999|
756 -|Word|MW|MWDDDDD|0~~99999|
757 -|Word|MD|MDDDDDD|0~~99999|
758 -
759 -**3)Cable Wiring**
760 -
761 -(% style="text-align:center" %)
762 -[[image:Hollysys485-2.png]]
763 -
764 -== **LM Modbus RTU** ==
765 -
766 -(% class="wikigeneratedid" %)
767 -Supported Series: HollySys LM3109/LM3107 PLC
768 -
769 -(% class="wikigeneratedid" %)
770 -**1)V-BOX setting**
771 -
772 -|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
773 -|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
774 -|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
775 -|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
776 -|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
777 -|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
778 -|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
779 -|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
780 -
781 -**2)Address List**
782 -
783 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
784 -|Bit|QX|QXDDDDD.o|0~~99999.7|
785 -|Bit|IX|IXDDDDD.o|0~~99999.7|
786 -|Bit|MX|MXDDDDD.o|0~~99999.7|
787 -|Word|QW|QWDDDDD|0~~99999|
788 -|Word|IW|IWDDDDD|0~~99999|
789 -|Word|MW|MWDDDDD|0~~99999|
790 -|Word|MD|MDDDDDD|0~~99999|
791 -
792 -**Cable Wiring**
793 -
794 -RS232
795 -
796 -(% style="text-align:center" %)
797 -[[image:HollySysRS232.png]]
798 -
799 -RS485
800 -
801 -(% style="text-align:center" %)
802 -[[image:Hollysys LM Modbus RTU.gif]]
803 -
804 804  = Create communication with **Siemens PLC** =
805 805  
806 806  == **S7-200 Smart Ethernet Protocol** ==
ControlStarCommunicate.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -46.3 KB
Content
HollySysRS232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -13.4 KB
Content