Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 248.1
edited by Theodore Xu
on 2023/07/10 11:07
Change comment: There is no comment for this version
To version 246.1
edited by Hunter
on 2023/07/05 11:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Hunter
Content
... ... @@ -1,5 +3,3 @@
1 -= Create communication with INVT =
2 -
3 3  = Create communication with WECON PLC =
4 4  
5 5  == **LX3V Serial Protocol** ==
... ... @@ -761,46 +761,6 @@
761 761  (% style="text-align:center" %)
762 762  [[image:Hollysys485-2.png]]
763 763  
764 -== **LM Modbus RTU** ==
765 -
766 -(% class="wikigeneratedid" %)
767 -Supported Series: HollySys LM3109/LM3107 PLC
768 -
769 -(% class="wikigeneratedid" %)
770 -**1)V-BOX setting**
771 -
772 -|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
773 -|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
774 -|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
775 -|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
776 -|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
777 -|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
778 -|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
779 -|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
780 -
781 -**2)Address List**
782 -
783 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
784 -|Bit|QX|QXDDDDD.o|0~~99999.7|
785 -|Bit|IX|IXDDDDD.o|0~~99999.7|
786 -|Bit|MX|MXDDDDD.o|0~~99999.7|
787 -|Word|QW|QWDDDDD|0~~99999|
788 -|Word|IW|IWDDDDD|0~~99999|
789 -|Word|MW|MWDDDDD|0~~99999|
790 -|Word|MD|MDDDDDD|0~~99999|
791 -
792 -**Cable Wiring**
793 -
794 -RS232
795 -
796 -(% style="text-align:center" %)
797 -[[image:HollySysRS232.png]]
798 -
799 -RS485
800 -
801 -(% style="text-align:center" %)
802 -[[image:Hollysys LM Modbus RTU.gif]]
803 -
804 804  = Create communication with **Siemens PLC** =
805 805  
806 806  == **S7-200 Smart Ethernet Protocol** ==
HollySysRS232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.1 KB
Content