Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 254.1
edited by Theodore Xu
on 2023/08/22 15:33
on 2023/08/22 15:33
Change comment:
There is no comment for this version
To version 257.1
edited by Theodore Xu
on 2023/08/23 19:31
on 2023/08/23 19:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,15 +1,7 @@ 1 -{{info}} 2 -✎Note: Communication Connection Description 1 += WECON = 3 3 4 -* Modbus TCP: Maximum 16 devices 5 -* Modbus RTU: Maximum 32 devices 6 -* Ethernet Protocol: Maximum 16 devices 7 -{{/info}} 3 +== **LX3V Serial ** == 8 8 9 -= Create communication with WECON PLC = 10 - 11 -== **LX3V Serial Protocol** == 12 - 13 13 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 14 14 15 15 **1)V-BOX setting** ... ... @@ -56,7 +56,7 @@ 56 56 57 57 [[image:image-20220824120524-3.png]] 58 58 59 -== **LX5V Serial Protocol** ==51 +== **LX5V Serial ** == 60 60 61 61 This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 62 62 ... ... @@ -126,7 +126,7 @@ 126 126 127 127 The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 128 128 129 -== **LX5V-N Ethernet protocol** ==121 +== **LX5V-N Ethernet ** == 130 130 131 131 This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 132 132 ... ... @@ -184,9 +184,9 @@ 184 184 185 185 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 186 186 187 -= Create communication withAllen-Bradley(**Rockwell**)** PLC**=179 += Allen-Bradley(**Rockwell**) = 188 188 189 -== **DF1 Advanced Protocol** ==181 +== **DF1 Advanced Serial** == 190 190 191 191 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 192 192 ... ... @@ -285,7 +285,7 @@ 285 285 (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 286 286 (% id="cke_bm_5621S" style="display:none" %)** ** 287 287 288 -== **MicroLogix Protocol** ==280 +== **MicroLogix Serial** == 289 289 290 290 (% class="wikigeneratedid" %) 291 291 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -325,7 +325,7 @@ 325 325 326 326 [[image:image-20220824110724-1.png]] 327 327 328 -== **Micro850_FreeTag Protocol** ==320 +== **Micro850_FreeTag Ethernet** == 329 329 330 330 ((( 331 331 ((( ... ... @@ -528,7 +528,7 @@ 528 528 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 529 529 530 530 531 -== **Micro850_FreeTag Protocol(new)** ==523 +== **Micro850_FreeTag Ethernet(new)** == 532 532 533 533 This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 534 534 ... ... @@ -671,9 +671,9 @@ 671 671 **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 672 672 {{/info}} 673 673 674 -= Create communication withEMERSONPLC=666 += EMERSON = 675 675 676 -= **RTU Slave Protocol** =668 += **RTU Slave ** = 677 677 678 678 Supported series: EC10 series 679 679 ... ... @@ -734,9 +734,9 @@ 734 734 (% style="text-align:center" %) 735 735 [[image:Emerson.png]] 736 736 737 -= Create communication withHollySys PLC =729 += HollySys PLC = 738 738 739 -== **LK Modbus RTU** == 731 +== **LK Modbus RTU ** == 740 740 741 741 Supported Series: HollySys LK series PLC 742 742 ... ... @@ -807,15 +807,14 @@ 807 807 (% style="text-align:center" %) 808 808 [[image:Hollysys LM Modbus RTU.gif]] 809 809 810 -= Create communication with**SiemensPLC** =802 += **Siemens ** = 811 811 812 -== **S7-200 Smart Ethernet Protocol** ==804 +== **S7-200 Smart Ethernet ** == 813 813 814 814 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 815 815 808 +== **S7-300 Ethernet ** == 816 816 817 -== **S7-300 Ethernet Protocol** == 818 - 819 819 Supported Series: Siemens S7-300 series PLC 820 820 821 821 **1)V-BOX setting** ... ... @@ -872,11 +872,11 @@ 872 872 ))) 873 873 ))) 874 874 875 -== **S7-1200 Ethernet Protocol** ==866 +== **S7-1200 Ethernet ** == 876 876 877 877 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 878 878 879 -== **S7-XXX Ethernet Protocol** ==870 +== **S7-XXX Ethernet l** == 880 880 881 881 Supported Series: Siemens S7-400, S7-1200 and S7-1500 882 882 ... ... @@ -990,7 +990,7 @@ 990 990 991 991 [[image:image-20220824162342-2.png]] 992 992 993 -== **LOGO Ethernet Protocol** ==984 +== **LOGO Ethernet ** == 994 994 995 995 Supported Series: Siemens Logo 0BA0, 0BA1 series 996 996 ... ... @@ -1081,9 +1081,9 @@ 1081 1081 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 1082 1082 ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 1083 1083 1084 -= Create communication with**MitsubishiPLC** =1075 += **Mitsubishi ** = 1085 1085 1086 -== **FX1S,1N,2N Serial Protocol** ==1077 +== **FX1S,1N,2N Serial ** == 1087 1087 1088 1088 Supported Series: Mitsubishi FX1S, FX1N, FX2N series 1089 1089 ... ... @@ -1130,7 +1130,7 @@ 1130 1130 [[image:image-20220825100845-4.png]] 1131 1131 1132 1132 1133 -== **FX3U,3G,3GA Serial Protocol** ==1124 +== **FX3U,3G,3GA Serial ** == 1134 1134 1135 1135 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 1136 1136 ... ... @@ -1177,7 +1177,7 @@ 1177 1177 [[image:image-20220825100845-4.png]] 1178 1178 1179 1179 1180 -== **FX3U Ethernet Protocol** ==1171 +== **FX3U Ethernet ** == 1181 1181 1182 1182 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 1183 1183 ... ... @@ -1272,7 +1272,7 @@ 1272 1272 1273 1273 [[image:image-20221119101946-2.png||height="395" width="695"]] 1274 1274 1275 -== **FX5U Serial Protocol** ==1266 +== **FX5U Serial ** == 1276 1276 1277 1277 Mitsubishi FX5U series PLC 1278 1278 ... ... @@ -1354,7 +1354,7 @@ 1354 1354 1355 1355 [[image:image-20220825105533-3.png]] 1356 1356 1357 -== **FX5U Ethernet Protocol** ==1348 +== **FX5U Ethernet ** == 1358 1358 1359 1359 Mitsubishi FX5U series PLC 1360 1360 ... ... @@ -1430,7 +1430,7 @@ 1430 1430 1431 1431 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1432 1432 1433 -== **L02 Serial Protocol** ==1424 +== **L02 Serial ** == 1434 1434 1435 1435 Mitsubishi L02 series CPU built-in serial port. 1436 1436 ... ... @@ -1490,7 +1490,7 @@ 1490 1490 1491 1491 [[image:image-20220825160820-4.png]] 1492 1492 1493 -== **L02 Ethernet Protocol** ==1484 +== **L02 Ethernet ** == 1494 1494 1495 1495 Mitsubishi L series CPU built-in Ethernet port. 1496 1496 ... ... @@ -1563,13 +1563,13 @@ 1563 1563 1564 1564 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1565 1565 1566 -== **Q12H Serial Protocol** ==1557 +== **Q12H Serial ** == 1567 1567 1568 1568 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1569 1569 1570 1570 [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1571 1571 1572 -== **QJ71E71 Ethernet Protocol** ==1563 +== **QJ71E71 Ethernet ** == 1573 1573 1574 1574 Mitsubishi QJ71E71 Ethernet communication module; 1575 1575 ... ... @@ -1644,9 +1644,9 @@ 1644 1644 1645 1645 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1646 1646 1647 -= Create communication with**DeltaPLC** =1638 += **Delta** = 1648 1648 1649 -== **DVP Ethernet Protocol** ==1640 +== **DVP Ethernet** == 1650 1650 1651 1651 Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1652 1652 ... ... @@ -1711,7 +1711,7 @@ 1711 1711 (% style="text-align:center" %) 1712 1712 [[image:DVPEthernetVNETPortocol.png]] 1713 1713 1714 -== **DVP serial protocol** ==1705 +== **DVP serial** == 1715 1715 1716 1716 Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1717 1717 ... ... @@ -1747,7 +1747,7 @@ 1747 1747 (% style="text-align:center" %) 1748 1748 [[image:Delta DVP PROTOCOLSerial232.png]] 1749 1749 1750 -== **AS Ethernet Protocol** ==1741 +== **AS Ethernet** == 1751 1751 1752 1752 **1)V-BOX Settings** 1753 1753 ... ... @@ -1792,19 +1792,18 @@ 1792 1792 1793 1793 [[image:image-20220831155157-3.png]] 1794 1794 1795 -= Create communication with**OmronPLC** =1786 += **Omron** = 1796 1796 1797 -== **CP1 Series Protocol** ==1788 +== **CP1 Series** == 1798 1798 1799 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1800 1800 1801 -== **CP2M Series Protocol** ==1792 +== **CP2M Series** == 1802 1802 1803 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1804 1804 1796 +== **EC55 Series ** == 1805 1805 1806 -== **EC55 Series Protocol** == 1807 - 1808 1808 Supported device: EC55 temperature instrument 1809 1809 1810 1810 **1)V-BOX Settings** ... ... @@ -1864,9 +1864,9 @@ 1864 1864 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1865 1865 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1866 1866 1867 -= Create communication withXinje** PLC**=1857 += Xinje = 1868 1868 1869 -== **XC serial protocol** ==1859 +== **XC serial** == 1870 1870 1871 1871 **1)V-BOX Settings** 1872 1872 ... ... @@ -1908,7 +1908,7 @@ 1908 1908 1909 1909 [[image:image-20220831163441-4.png]] 1910 1910 1911 -== **XD serial protocol** ==1901 +== **XD serial** == 1912 1912 1913 1913 **1)V-BOX Settings** 1914 1914 ... ... @@ -1982,7 +1982,7 @@ 1982 1982 1983 1983 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1984 1984 1985 -= Create communication with**SchneiderPLC** =1975 += **Schneider** = 1986 1986 1987 1987 == **Schneider MODBUS RTU** == 1988 1988 ... ... @@ -2016,7 +2016,7 @@ 2016 2016 2017 2017 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 2018 2018 2019 -= Create communication withInovance** PLC**=2009 += Inovance = 2020 2020 2021 2021 == **H3U serial protocol** == 2022 2022 ... ... @@ -2068,9 +2068,9 @@ 2068 2068 2069 2069 [[image:image-20220831164731-4.png]] 2070 2070 2071 -= Create communication withPanasonic** PLC**=2061 += Panasonic = 2072 2072 2073 -== **FP serial protocol** ==2063 +== **FP serial** == 2074 2074 2075 2075 **1)V-BOX Settings** 2076 2076 ... ... @@ -2118,9 +2118,9 @@ 2118 2118 2119 2119 [[image:image-20220831165008-1.png]] 2120 2120 2121 -= Create communication withLS** PLC**=2111 += LS = 2122 2122 2123 -== **XBC serial protocol** ==2113 +== **XBC serial** == 2124 2124 2125 2125 **1)V-BOX Settings** 2126 2126 ... ... @@ -2172,7 +2172,7 @@ 2172 2172 2173 2173 [[image:image-20220831170215-2.png]] 2174 2174 2175 -== **XGK FEnet Ethernet protocol** ==2165 +== **XGK FEnet Ethernet** == 2176 2176 2177 2177 Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2178 2178 ... ... @@ -2215,7 +2215,7 @@ 2215 2215 2216 2216 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2217 2217 2218 -= Create communication withINVTPLC=2208 += INVT = 2219 2219 2220 2220 **1)V-BOX setting** 2221 2221 ... ... @@ -2283,7 +2283,7 @@ 2283 2283 (% style="text-align:center" %) 2284 2284 [[image:wire.png]] 2285 2285 2286 -= Create communication with**Modbus ** =2276 += **Modbus ** = 2287 2287 2288 2288 == **MODBUS RTU Slave (All function)** == 2289 2289 ... ... @@ -2294,7 +2294,7 @@ 2294 2294 (% style="text-align:center" %) 2295 2295 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 2296 2296 2297 -== ** Communicate withModbus Meter** ==2287 +== **Modbus Meter** == 2298 2298 2299 2299 The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2300 2300