Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 27.1
edited by Ben
on 2022/08/20 11:59
Change comment: There is no comment for this version
To version 22.1
edited by Ben
on 2022/08/20 11:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,7 @@
1 -= **Modbus RTU** =
1 += **1 General communication with PLC** =
2 2  
3 +== **Modbus RTU** ==
4 +
3 3  === **V-BOX as master** ===
4 4  
5 5  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
... ... @@ -45,7 +45,7 @@
45 45  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
46 46  |0F (Write multiple bits)
47 47  
48 -= **WECON PLC** =
50 += ** WECON PLC** =
49 49  
50 50  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
51 51  
... ... @@ -245,9 +245,10 @@
245 245  (% style="text-align:center" %)
246 246  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
247 247  
248 -= **Rockwell PLC** =
250 +(% class="wikigeneratedid" %)
251 +== **Rockwell** ==
249 249  
250 -== **Communication with AB CompactLogix L1769** ==
253 +== **Communication with Allen-Bradley CompactLogix L1769** ==
251 251  
252 252  (((
253 253  (((
... ... @@ -450,14 +450,6 @@
450 450  
451 451  (((
452 452  The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
453 -
454 -
455 -== **Allen-Bradley Ethernet DF1** ==
456 -
457 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
458 -
459 -
460 -= **Siemens PLC** =
461 461  )))
462 462  )))
463 463  
... ... @@ -465,12 +465,14 @@
465 465  
466 466  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
467 467  
463 +== **Allen-Bradley Ethernet DF1** ==
464 +
465 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
466 +
468 468  == **Communication with S7-200 Smart** ==
469 469  
470 470  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
471 471  
472 -= **Delta PLC** =
473 -
474 474  == **Delta DVP Ethernet** ==
475 475  
476 476  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]