Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,6 +47,8 @@ 47 47 48 48 = **WECON PLC** = 49 49 50 +== **V-BOX 和维控 LX3V 串行通信** == 51 + 50 50 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 51 51 52 52 **HMI Settings** ... ... @@ -82,14 +82,13 @@ 82 82 83 83 * **RS485** 84 84 85 -(% style="text-align:center" %) 86 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 87 + [[image:image-20220822172124-1.png]] 87 87 88 88 * **RS422** 89 89 90 -(% style="text-align:center" %) 91 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 91 + [[image:image-20220822172228-2.png]] 92 92 93 + 93 93 **✎Note:** 94 94 95 95 * HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . ... ... @@ -98,24 +98,22 @@ 98 98 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 99 99 100 100 101 -== ** HMIand Wecon LX5V serial communication** ==102 +== **V-BOX and Wecon LX5V serial communication** == 102 102 103 -This example introduces the establishment of serial port communication between Wecon HMIand LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.104 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 104 104 105 105 **Software configuration of PLC** 106 106 107 107 **1)PLC programming software** 108 108 109 -[[image:image-2022081 0164710-1.png]]110 +[[image:image-20220822172553-1.png]] 110 110 111 - 112 112 **2)New PLC project** 113 113 114 114 Click New Project and select the PLC model. 115 115 116 -[[image:image-2022081 0172412-1.png]]116 +[[image:image-20220822172623-2.png]] 117 117 118 - 119 119 **3)Set Serial port parameters** 120 120 121 121 Follow the steps below to configure Serial port parameters ... ... @@ -128,27 +128,25 @@ 128 128 129 129 Parity:No verification 130 130 131 -[[image:image-2022081 0165759-3.png]]130 +[[image:image-20220822172657-3.png]] 132 132 133 - 134 134 **4)Registers list** 135 135 136 -[[image:image-202208 11102219-3.png]]134 +[[image:image-20220822172730-4.png]] 137 137 136 +**V-BOX software configuration** 138 138 139 -** HMIsoftwareconfiguration**138 +**1)V-BOX programming software** 140 140 141 - **1)HMIprogrammingsoftware**140 + [[image:image-20220824104124-1.png]] 142 142 143 - [[image:image-20220810171237-4.png]]142 +**2)V-NET add device** 144 144 145 - **2)NewHMIproject**144 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 146 146 147 - Click New Projectand select the HMImodel.146 +[[image:image-20220824104909-2.png]] 148 148 149 -[[image:image-20220810172010-5.png]] 150 150 151 - 152 152 **3)Set communication port parameters** 153 153 154 154 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -178,7 +178,7 @@ 178 178 179 179 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 180 180 181 -== ** HMIand Wecon LX5V-N Ethernet communication** ==178 +== **V-BOX and Wecon LX5V-N Ethernet communication** == 182 182 183 183 This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 184 184 ... ... @@ -253,14 +253,52 @@ 253 253 254 254 = **Rockwell PLC** = 255 255 256 -== **Communication with AB CompactLogix L1769** == 257 257 254 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 255 + 256 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 257 + 258 +**HMI Settings** 259 + 260 +|**Item**|**Settings**|**Note** 261 +|Protocol|Allen-Bradlley MicroLogix| 262 +|Connection|RS232| 263 +|Baud rate|19200| 264 +|Data bit|8| 265 +|Parity|None| 266 +|Stop bit|1| 267 +|PLC station No.|1| 268 + 269 +**Address List** 270 + 271 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 272 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 273 +|O|O d.d|0.0~~255.15| 274 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 275 +|S|S d.d|0.0~~255.15| 276 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 277 +|(% rowspan="9" %)Word|S|S d|0~~255| 278 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 279 +|TP|TP nnhh|0~~ffff 280 +|CS|CS nnhh|0~~ffff 281 +|CP|CP nnhh|0~~ffff 282 +|N|N nnhh|0~~ffff 283 +|C|C nnhh|0~~ffff 284 +|T|T nnhh|0~~ffff 285 +|R|R nnhh|0~~ffff 286 + 287 +**Cable Wiring** 288 + 289 +[[image:image-20220824110724-1.png]] 290 + 291 + 292 + 293 +== **CompactLogix** == 294 + 258 258 ((( 259 259 ((( 260 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-BradleyL1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.297 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 261 261 ))) 262 - 263 - 264 264 ))) 265 265 266 266 (((
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content
- image-20220822172553-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- image-20220822172623-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220822172657-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +141.6 KB - Content
- image-20220822172730-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +130.7 KB - Content
- image-20220824104124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.6 KB - Content
- image-20220824104909-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +278.8 KB - Content
- image-20220824110724-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content