Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,7 @@ 1 -= ** ModbusRTU** =1 += **1 General communication with PLC** = 2 2 3 +== **Modbus RTU** == 4 + 3 3 === **V-BOX as master** === 4 4 5 5 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -45,216 +45,19 @@ 45 45 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 46 |0F (Write multiple bits) 47 47 48 -= **WECON PLC** = 50 +== **WECON LX3V PLC** == 49 49 50 -S upportedseries:WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM52 +Select the protocol (% class="mark" %)"WECON LX3V" 51 51 52 - **HMISettings**54 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC. 53 53 54 -|**Item**|**Settings**|**Note** 55 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 56 -|Connection|RS422/RS485| 57 -|Baud rate|9600| 58 -|Data bit|7| 59 -|Parity|EVEN| 60 -|Stop bit|1| 61 -|PLC station No.|1| 56 +(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN 62 62 63 -**Address List** 64 - 65 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 66 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 67 -|Y|Y|Y o|0~~303237| 68 -|M|M|M d|0~~99999| 69 -|T|T|T d|0~~99999| 70 -|C|C|C d|0~~99999| 71 -|S|S|S d|0~~99999| 72 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 73 -|Y|Y|Y o|0~~303237| 74 -|M|M|M d|0~~99999| 75 -|T|T|T d|0~~99999| 76 -|C|C|C d|0~~199| 77 -|D|D|D d|0~~7999| 78 -|S|S|S d|0~~99999| 79 -|SD|SD|SD d|8000~~9999| 80 - 81 -**Cable Wiring** 82 - 83 -* **RS485** 84 - 85 85 (% style="text-align:center" %) 86 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 87 - 88 -* **RS422** 89 - 90 -(% style="text-align:center" %) 91 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 92 - 93 -**✎Note:** 94 - 95 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 96 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 97 - 98 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 99 - 100 - 101 -== **V-BOX and Wecon LX5V serial communication** == 102 - 103 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 104 - 105 -**Software configuration of PLC** 106 - 107 -**1)PLC programming software** 108 - 109 -[[image:image-20220810164710-1.png]] 110 - 111 - 112 -**2)New PLC project** 113 - 114 -Click New Project and select the PLC model. 115 - 116 -[[image:image-20220810172412-1.png]] 117 - 118 - 119 -**3)Set Serial port parameters** 120 - 121 -Follow the steps below to configure Serial port parameters 122 - 123 -Baud rate:115200 124 - 125 -Data bit:8 126 - 127 -Stop bit:1 128 - 129 -Parity:No verification 130 - 131 -[[image:image-20220810165759-3.png]] 132 - 133 - 134 -**4)Registers list** 135 - 136 -[[image:image-20220811102219-3.png]] 137 - 138 - 139 -**HMI software configuration** 140 - 141 -**1)HMI programming software** 142 - 143 - [[image:image-20220810171237-4.png]] 144 - 145 -**2)New HMI project** 146 - 147 -Click New Project and select the HMI model. 148 - 149 -[[image:image-20220810172010-5.png]] 150 - 151 - 152 -**3)Set communication port parameters** 153 - 154 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 155 - 156 -Baud rate:115200 157 - 158 -Data bit:8 159 - 160 -Stop bit:1 161 - 162 -Parity:No verification 163 - 164 -[[image:image-20220811104012-1.png]] 165 - 166 - 167 -**hardware connection** 168 - 169 -**1)Hardware wiring diagram** 170 - 171 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 172 - 173 - 174 - 175 -[[image:image-20220811103005-4.png]] 176 - 177 -[[image:image-20220811103227-7.png]] 178 - 179 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 180 - 181 -== **HMI and Wecon LX5V-N Ethernet communication** == 182 - 183 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 184 - 185 -**Software configuration of PLC** 186 - 187 -**1)PLC programming software** 188 - 189 -[[image:image-20220810164710-1.png]] 190 - 191 -**2)New PLC project** 192 - 193 -Click New Project and select the PLC model. 194 - 195 -[[image:image-20220811115454-1.png]] 196 - 197 -**3)Set Ethernet port parameters** 198 - 199 -Follow the steps below to configure Ethernet parameters 200 - 201 -PLC IP address:192.168.39.200 202 - 203 -default gateway:192.168.39.1 204 - 205 -subnet mask:255.255.255.0 206 - 207 -[[image:image-20220811140530-2.png]] 208 - 209 -**4)Registers list** 210 - 211 -[[image:image-20220811102219-3.png]] 212 - 213 -**HMI software configuration** 214 - 215 -**1)HMI programming software** 216 - 217 - [[image:image-20220810171237-4.png]] 218 - 219 -**2)New HMI project** 220 - 221 -Click New Project and select the HMI model. 222 - 223 -[[image:image-20220810172010-5.png]] 224 - 225 -**3)Set communication port parameters** 226 - 227 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 228 - 229 -HMI IP address:192.168.39.201 230 - 231 -default gateway:192.168.39.1 232 - 233 -subnet mask:255.255.255.0 234 - 235 -[[image:image-20220811170753-2.png]] 236 - 237 -Next, click Communication Settings to configure the IP of the HMI communication object. 238 - 239 -[[image:image-20220811163047-1.png]] 240 - 241 -**hardware connection** 242 - 243 -**1)Hardware wiring diagram** 244 - 245 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 246 - 247 -[[image:image-20220811170248-1.png]] 248 - 249 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 250 - 251 -(% style="text-align:center" %) 252 252 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 253 253 254 -= ** RockwellPLC** =61 +== **2 Communication with Allen-Bradley CompactLogix L1769** == 255 255 256 -== **Communication with AB CompactLogix L1769** == 257 - 258 258 ((( 259 259 ((( 260 260 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. ... ... @@ -394,7 +394,7 @@ 394 394 395 395 ((( 396 396 ((( 397 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 202 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 398 398 ))) 399 399 400 400 ... ... @@ -421,7 +421,7 @@ 421 421 422 422 423 423 ((( 424 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 229 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 425 425 ))) 426 426 427 427 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -456,14 +456,6 @@ 456 456 457 457 ((( 458 458 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 459 - 460 - 461 -== **Allen-Bradley Ethernet DF1** == 462 - 463 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 464 - 465 - 466 -= **Siemens PLC** = 467 467 ))) 468 468 ))) 469 469 ... ... @@ -471,12 +471,14 @@ 471 471 472 472 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 473 473 271 +== **Allen-Bradley Ethernet DF1** == 272 + 273 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 274 + 474 474 == **Communication with S7-200 Smart** == 475 475 476 476 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 477 477 478 -= **Delta PLC** = 479 - 480 480 == **Delta DVP Ethernet** == 481 481 482 482 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] ... ... @@ -503,7 +503,7 @@ 503 503 504 504 = **2 User define protocol** = 505 505 506 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 305 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 507 507 508 508 == **Read the temperature sensor.** == 509 509
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.4 KB - Content