Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
To version 13.1
edited by Ben
on 2022/07/14 14:37
on 2022/07/14 14:37
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 11 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 Communication with device1 +1 Communication - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Leo1 +XWiki.Ben - Content
-
... ... @@ -1,8 +1,8 @@ 1 1 = **1 General communication with PLC** = 2 2 3 -== ** 1.1Modbus RTU** ==3 +== **Modbus RTU** == 4 4 5 -=== =V-Boxas master:====5 +=== **V-BOX as master** === 6 6 7 7 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 8 8 ... ... @@ -9,9 +9,9 @@ 9 9 (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 10 10 11 11 (% style="text-align:center" %) 12 -[[image:1624342015914-382.png|| class="img-thumbnail" height="486" width="800"]]12 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 13 13 14 -=== =V-Boxas slave:====14 +=== **V-BOX as slave** === 15 15 16 16 Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 17 17 ... ... @@ -18,7 +18,7 @@ 18 18 (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 19 19 20 20 (% style="text-align:center" %) 21 -[[image:1624348709622-711.png||queryString="width=809&height=493" class="img-thumbnail" height="488" width="800"]]21 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 22 22 23 23 **Address List** 24 24 ... ... @@ -47,7 +47,7 @@ 47 47 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 48 |0F (Write multiple bits) 49 49 50 -== ** 1.2WECON LX3V PLC** ==50 +== **WECON LX3V PLC** == 51 51 52 52 Select the protocol (% class="mark" %)"WECON LX3V" 53 53 ... ... @@ -56,33 +56,163 @@ 56 56 (% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN 57 57 58 58 (% style="text-align:center" %) 59 -[[image:1624348978863-771.png||queryString="width=812&height=494" class="img-thumbnail" height="487" width="800"]]59 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 60 60 61 -== ** 1.3SiemensS7-1200** ==61 +== **2 Communication with Allen-Bradley CompactLogix L1769** == 62 62 63 +=== **Overview** === 64 + 65 +((( 66 +This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 67 +))) 68 + 69 +((( 70 + 71 +))) 72 + 73 +((( 74 +== **Software configuration of PLC** == 75 + 76 +=== **PLC programming software** === 77 + 78 + [[image:image-20220714113935-3.png]] 79 + 80 +=== **New PLC project** === 81 + 82 +((( 83 +Click New Project and select the PLC model. 84 +))) 85 + 86 +((( 87 + [[image:image-20220714114247-4.png]] 88 +))) 89 + 90 +((( 91 + [[image:image-20220714114257-5.png]] 92 +))) 93 + 94 +((( 95 + 96 +))) 97 + 98 +((( 99 +=== **Set Ethernet parameters** === 100 + 101 +((( 102 +Follow the steps below to configure Ethernet parameters 103 +))) 104 + 105 +((( 106 +PLC IP address:192.168.40.101 107 +))) 108 + 109 +((( 110 +default gateway:192.168.40.1 111 +))) 112 + 113 +((( 114 +subnet mask:255.255.255.0 115 +))) 116 + 117 +((( 118 + [[image:image-20220714115012-6.png]] 119 +))) 120 + 121 +((( 122 + 123 +))) 124 + 125 +((( 126 +== **V-box software configuration** == 127 + 128 +=== **V-box programming software** === 129 + 130 + [[image:image-20220714115214-7.png]] 131 + 132 + 133 +=== **Configure device network** === 134 + 135 +((( 136 +Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. 137 +))) 138 + 139 +((( 140 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection. 141 +))) 142 + 143 + [[image:image-20220714115440-9.png||height="425" width="791"]] 144 +))) 145 +))) 146 + 147 +== **V-net add device** == 148 +))) 149 + 150 +((( 151 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 152 +))) 153 + 154 +((( 155 + [[image:image-20220714115640-10.png||height="430" width="797"]] 156 +))) 157 + 158 +((( 159 + 160 +))) 161 + 162 +((( 163 +=== **Set communication port parameters** === 164 + 165 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 166 + 167 + [[image:image-20220714115848-11.png||height="432" width="802"]] 168 +))) 169 + 170 + 171 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 172 + 173 + 174 + 175 +== **Siemens S7-1200** == 176 + 63 63 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 64 64 65 -== ** 1.4Allen-Bradley Ethernet DF1** ==179 +== **Allen-Bradley Ethernet DF1** == 66 66 67 67 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 68 68 69 -== ** 1.5Communication with S7-200 Smart** ==183 +== **Communication with S7-200 Smart** == 70 70 71 71 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 72 72 73 -== ** 1.6Delta DVP Ethernet** ==187 +== **Delta DVP Ethernet** == 74 74 75 75 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 76 76 77 -== ** 1.7Delta DVP Serial Protocol** ==191 +== **Delta DVP Serial Protocol** == 78 78 79 79 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 80 80 195 +== **Communicate with Mitsubishi FX Series** == 196 + 197 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 198 + 199 +== **Communicate with VB inverter** == 200 + 201 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 202 + 203 +== **Omron CP1 Series** == 204 + 205 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 206 + 207 +== **Omron CJ2M** == 208 + 209 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 210 + 81 81 = **2 User define protocol** = 82 82 83 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 \.Luascript function.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]213 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 84 84 85 -== ** 2.1Read the temperature sensor.** ==215 +== **Read the temperature sensor.** == 86 86 87 87 the commond format is as beliow: 88 88
- image-20220714113815-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +907.8 KB - Content
- image-20220714113842-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.8 KB - Content
- image-20220714113935-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.0 KB - Content
- image-20220714114247-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714114257-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 MB - Content
- image-20220714115012-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content
- image-20220714115214-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.0 MB - Content
- image-20220714115308-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +718 bytes - Content
- image-20220714115440-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.1 MB - Content
- image-20220714115640-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714115848-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content