Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 30.1
edited by Ben
on 2022/08/22 17:22
Change comment: There is no comment for this version
To version 5.1
edited by Leo
on 2022/06/16 17:21
Change comment: Renamed from xwiki:V-BOX.V-Net.Training.1\.Communication.WebHome

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -1 Communication
1 +1 Communication with device
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Leo
Content
... ... @@ -1,15 +1,17 @@
1 -= **Modbus RTU** =
1 += **1 General communication with PLC** =
2 2  
3 -=== **V-BOX as master** ===
3 +== **1.1 Modbus RTU** ==
4 4  
5 +==== V-Box as master: ====
6 +
5 5  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
6 6  
7 7  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
8 8  
9 9  (% style="text-align:center" %)
10 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
12 +[[image:1624342015914-382.png||class="img-thumbnail" height="486" width="800"]]
11 11  
12 -=== **V-BOX as slave** ===
14 +==== V-Box as slave: ====
13 13  
14 14  Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
15 15  
... ... @@ -16,7 +16,7 @@
16 16  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
17 17  
18 18  (% style="text-align:center" %)
19 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
21 +[[image:1624348709622-711.png||queryString="width=809&height=493" class="img-thumbnail" height="488" width="800"]]
20 20  
21 21  **Address List**
22 22  
... ... @@ -45,466 +45,42 @@
45 45  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
46 46  |0F (Write multiple bits)
47 47  
48 -= **WECON PLC** =
50 +== **1.2 WECON LX3V PLC** ==
49 49  
50 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
52 +Select the protocol (% class="mark" %)"WECON LX3V"
51 51  
52 -**HMI Settings**
54 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
53 53  
54 -|**Item**|**Settings**|**Note**
55 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
56 -|Connection|RS422/RS485|
57 -|Baud rate|9600|
58 -|Data bit|7|
59 -|Parity|EVEN|
60 -|Stop bit|1|
61 -|PLC station No.|1|
56 +(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
62 62  
63 -**Address List**
64 -
65 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
66 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
67 -|Y|Y|Y o|0~~303237|
68 -|M|M|M d|0~~99999|
69 -|T|T|T d|0~~99999|
70 -|C|C|C d|0~~99999|
71 -|S|S|S d|0~~99999|
72 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 -|Y|Y|Y o|0~~303237|
74 -|M|M|M d|0~~99999|
75 -|T|T|T d|0~~99999|
76 -|C|C|C d|0~~199|
77 -|D|D|D d|0~~7999|
78 -|S|S|S d|0~~99999|
79 -|SD|SD|SD d|8000~~9999|
80 -
81 -**Cable Wiring**
82 -
83 -* **RS485**
84 -
85 - [[image:image-20220822172124-1.png]]
86 -
87 -* **RS422**
88 -
89 - [[image:image-20220822172228-2.png]]
90 -
91 -
92 -**✎Note:**
93 -
94 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
95 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
96 -
97 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
98 -
99 -
100 -== **V-BOX and Wecon LX5V serial communication** ==
101 -
102 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
103 -
104 -**Software configuration of PLC**
105 -
106 -**1)PLC programming software**
107 -
108 -[[image:image-20220810164710-1.png]]
109 -
110 -
111 -**2)New PLC project**
112 -
113 -Click New Project and select the PLC model.
114 -
115 -[[image:image-20220810172412-1.png]]
116 -
117 -
118 -**3)Set Serial port parameters**
119 -
120 -Follow the steps below to configure Serial port parameters
121 -
122 -Baud rate:115200
123 -
124 -Data bit:8
125 -
126 -Stop bit:1
127 -
128 -Parity:No verification
129 -
130 -[[image:image-20220810165759-3.png]]
131 -
132 -
133 -**4)Registers list**
134 -
135 -[[image:image-20220811102219-3.png]]
136 -
137 -
138 -**HMI software configuration**
139 -
140 -**1)HMI programming software**
141 -
142 - [[image:image-20220810171237-4.png]]
143 -
144 -**2)New HMI project**
145 -
146 -Click New Project and select the HMI model.
147 -
148 -[[image:image-20220810172010-5.png]]
149 -
150 -
151 -**3)Set communication port parameters**
152 -
153 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
154 -
155 -Baud rate:115200
156 -
157 -Data bit:8
158 -
159 -Stop bit:1
160 -
161 -Parity:No verification
162 -
163 -[[image:image-20220811104012-1.png]]
164 -
165 -
166 -**hardware connection**
167 -
168 -**1)Hardware wiring diagram**
169 -
170 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
171 -
172 -
173 -
174 -[[image:image-20220811103005-4.png]]
175 -
176 -[[image:image-20220811103227-7.png]]
177 -
178 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
179 -
180 -== **HMI and Wecon LX5V-N Ethernet communication** ==
181 -
182 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
183 -
184 -**Software configuration of PLC**
185 -
186 -**1)PLC programming software**
187 -
188 -[[image:image-20220810164710-1.png]]
189 -
190 -**2)New PLC project**
191 -
192 -Click New Project and select the PLC model.
193 -
194 -[[image:image-20220811115454-1.png]]
195 -
196 -**3)Set Ethernet port parameters**
197 -
198 -Follow the steps below to configure Ethernet parameters
199 -
200 -PLC IP address:192.168.39.200
201 -
202 -default gateway:192.168.39.1
203 -
204 -subnet mask:255.255.255.0
205 -
206 -[[image:image-20220811140530-2.png]]
207 -
208 -**4)Registers list**
209 -
210 -[[image:image-20220811102219-3.png]]
211 -
212 -**HMI software configuration**
213 -
214 -**1)HMI programming software**
215 -
216 - [[image:image-20220810171237-4.png]]
217 -
218 -**2)New HMI project**
219 -
220 -Click New Project and select the HMI model.
221 -
222 -[[image:image-20220810172010-5.png]]
223 -
224 -**3)Set communication port parameters**
225 -
226 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
227 -
228 -HMI IP address:192.168.39.201
229 -
230 -default gateway:192.168.39.1
231 -
232 -subnet mask:255.255.255.0
233 -
234 -[[image:image-20220811170753-2.png]]
235 -
236 -Next, click Communication Settings to configure the IP of the HMI communication object.
237 -
238 -[[image:image-20220811163047-1.png]]
239 -
240 -**hardware connection**
241 -
242 -**1)Hardware wiring diagram**
243 -
244 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
245 -
246 -[[image:image-20220811170248-1.png]]
247 -
248 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
249 -
250 250  (% style="text-align:center" %)
251 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
59 +[[image:1624348978863-771.png||queryString="width=812&height=494" class="img-thumbnail" height="487" width="800"]]
252 252  
253 -= **Rockwell PLC** =
61 +== **1.3 Siemens S7-1200** ==
254 254  
255 -== **Communication with AB CompactLogix L1769** ==
63 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
256 256  
257 -(((
258 -(((
259 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
260 -)))
65 +== **1.4 Allen-Bradley Ethernet DF1** ==
261 261  
262 -
263 -)))
264 -
265 -(((
266 -(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
267 -(((
268 -**Software configuration of PLC**
269 -)))
270 -
271 -(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
272 -(((
273 -**1)PLC programming software**
274 -)))
275 -
276 -[[image:image-20220714162600-1.png]]
277 -
278 -(% class="wikigeneratedid" id="HNewPLCproject" %)
279 -(((
280 -**2)New PLC project**
281 -)))
282 -
283 -(((
284 -(((
285 -Click New Project and select the PLC model.
286 -)))
287 -)))
288 -
289 -(((
290 -[[image:image-20220714162617-2.png]]
291 -)))
292 -
293 -(((
294 -
295 -
296 -[[image:image-20220714162652-4.png]]
297 -)))
298 -
299 -(((
300 -(% class="wikigeneratedid" id="HSetEthernetparameters" %)
301 -(((
302 -**3)Set Ethernet parameters**
303 -)))
304 -
305 -(((
306 -(((
307 -(((
308 -Follow the steps below to configure Ethernet parameters
309 -)))
310 -)))
311 -)))
312 -
313 -(((
314 -(((
315 -(((
316 -PLC IP address:192.168.40.101
317 -)))
318 -)))
319 -)))
320 -
321 -(((
322 -(((
323 -(((
324 -default gateway:192.168.40.1
325 -)))
326 -)))
327 -)))
328 -
329 -(((
330 -(((
331 -(((
332 -subnet mask:255.255.255.0
333 -)))
334 -)))
335 -)))
336 -
337 -(((
338 -[[image:image-20220714162713-5.png]]
339 -)))
340 -
341 -(((
342 -
343 -)))
344 -
345 -(((
346 -(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
347 -(((
348 -**V-box software configuration**
349 -)))
350 -
351 -(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
352 -(((
353 -**1)V-box programming software**
354 -)))
355 -
356 -(% class="wikigeneratedid" %)
357 -(((
358 - [[image:image-20220714162725-6.png]]
359 -)))
360 -
361 -(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
362 -(((
363 -**2)Configure device network**
364 -)))
365 -
366 -(((
367 -(((
368 -(((
369 -Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
370 -)))
371 -
372 -(((
373 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
374 -)))
375 -)))
376 -)))
377 -
378 -(((
379 -(((
380 -[[image:image-20220714162737-7.png]]
381 -
382 -
383 -)))
384 -)))
385 -)))
386 -)))
387 -
388 -(% class="wikigeneratedid" id="HV-netadddevice" %)
389 -(((
390 -**3)V-net add device**
391 -)))
392 -)))
393 -
394 -(((
395 -(((
396 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
397 -)))
398 -
399 -
400 -)))
401 -
402 -(((
403 -(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
404 -(((
405 -**4)Set communication port parameters**
406 -)))
407 -
408 -(((
409 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
410 -)))
411 -
412 -[[image:image-20220714162805-9.png]]
413 -)))
414 -
415 -(((
416 -The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
417 -)))
418 -
419 -[[image:image-20220714162814-10.png]]
420 -
421 -
422 -(((
423 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
424 -)))
425 -
426 -(% class="wikigeneratedid" id="HEngineeringproduction" %)
427 -(((
428 -**5)Engineering production**
429 -)))
430 -
431 -(% class="wikigeneratedid" %)
432 -(((
433 -(((
434 -According to your own needs, use the V-NET client software to edit the required data monitoring points.
435 -)))
436 -
437 -[[image:image-20220714162841-12.png]]
438 -
439 -
440 -(((
441 -**hardware connection**
442 -)))
443 -)))
444 -
445 -(((
446 -**1)Hardware wiring diagram**
447 -)))
448 -
449 -(((
450 -(((
451 -This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
452 -)))
453 -
454 -[[image:image-20220714162856-13.png]]
455 -
456 -(((
457 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
458 -
459 -
460 -== **Allen-Bradley Ethernet DF1** ==
461 -
462 462  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
463 463  
69 +== **1.5 Communication with S7-200 Smart** ==
464 464  
465 -= **Siemens PLC** =
466 -)))
467 -)))
468 -
469 -== **Siemens S7-1200** ==
470 -
471 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
472 -
473 -== **Communication with S7-200 Smart** ==
474 -
475 475  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
476 476  
477 -= **Delta PLC** =
73 +== **1.6 Delta DVP Ethernet** ==
478 478  
479 -== **Delta DVP Ethernet** ==
480 -
481 481  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
482 482  
483 -== **Delta DVP Serial Protocol** ==
77 +== **1.7 Delta DVP Serial Protocol** ==
484 484  
485 485  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
486 486  
487 -== **Communicate with Mitsubishi FX Series** ==
488 -
489 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
490 -
491 -== **Communicate with VB inverter** ==
492 -
493 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
494 -
495 -== **Omron CP1 Series** ==
496 -
497 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
498 -
499 -== **Omron CJ2M** ==
500 -
501 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
502 -
503 503  = **2 User define protocol** =
504 504  
505 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
83 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
506 506  
507 -== **Read the temperature sensor.** ==
85 +== **2.1 Read the temperature sensor.** ==
508 508  
509 509  the commond format is as beliow:
510 510  
image-20220714113815-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -907.8 KB
Content
image-20220714113842-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.8 KB
Content
image-20220714113935-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.0 KB
Content
image-20220714114247-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20220714114257-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -2.0 MB
Content
image-20220714115012-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 MB
Content
image-20220714115214-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.0 MB
Content
image-20220714115308-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -718 bytes
Content
image-20220714115440-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 MB
Content
image-20220714115640-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20220714115848-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20220714143820-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20220714160006-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -131.6 KB
Content
image-20220820164423-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -48.8 KB
Content