Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,7 @@ 1 -= ** ModbusRTU** =1 += **1 General communication with PLC** = 2 2 3 +== **Modbus RTU** == 4 + 3 3 === **V-BOX as master** === 4 4 5 5 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -45,10 +45,8 @@ 45 45 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 46 |0F (Write multiple bits) 47 47 48 -= **WECON PLC** = 50 += ** WECON PLC** = 49 49 50 -== **V-BOX 和维控 LX3V 串行通信** == 51 - 52 52 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 53 53 54 54 **HMI Settings** ... ... @@ -84,13 +84,17 @@ 84 84 85 85 * **RS485** 86 86 87 - [[image:image-20220822172124-1.png]] 87 +(% style="text-align:center" %) 88 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 88 88 90 +(% style="text-align:center" %) 91 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 92 + 89 89 * **RS422** 90 90 91 - [[image:image-20220822172228-2.png]] 95 +(% style="text-align:center" %) 96 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 92 92 93 - 94 94 **✎Note:** 95 95 96 96 * HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . ... ... @@ -98,9 +98,8 @@ 98 98 99 99 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 100 100 105 +== HMI and Wecon LX5V serial communication == 101 101 102 -== **V-BOX and Wecon LX5V serial communication** == 103 - 104 104 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 105 105 106 106 **Software configuration of PLC** ... ... @@ -109,7 +109,6 @@ 109 109 110 110 [[image:image-20220810164710-1.png]] 111 111 112 - 113 113 **2)New PLC project** 114 114 115 115 Click New Project and select the PLC model. ... ... @@ -116,7 +116,6 @@ 116 116 117 117 [[image:image-20220810172412-1.png]] 118 118 119 - 120 120 **3)Set Serial port parameters** 121 121 122 122 Follow the steps below to configure Serial port parameters ... ... @@ -131,12 +131,10 @@ 131 131 132 132 [[image:image-20220810165759-3.png]] 133 133 134 - 135 135 **4)Registers list** 136 136 137 137 [[image:image-20220811102219-3.png]] 138 138 139 - 140 140 **HMI software configuration** 141 141 142 142 **1)HMI programming software** ... ... @@ -149,7 +149,6 @@ 149 149 150 150 [[image:image-20220810172010-5.png]] 151 151 152 - 153 153 **3)Set communication port parameters** 154 154 155 155 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -164,7 +164,6 @@ 164 164 165 165 [[image:image-20220811104012-1.png]] 166 166 167 - 168 168 **hardware connection** 169 169 170 170 **1)Hardware wiring diagram** ... ... @@ -171,8 +171,6 @@ 171 171 172 172 This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 173 173 174 - 175 - 176 176 [[image:image-20220811103005-4.png]] 177 177 178 178 [[image:image-20220811103227-7.png]] ... ... @@ -179,7 +179,7 @@ 179 179 180 180 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 181 181 182 -== **V-BOXand Wecon LX5V-N Ethernet communication**==177 +== HMI and Wecon LX5V-N Ethernet communication == 183 183 184 184 This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 185 185 ... ... @@ -252,10 +252,8 @@ 252 252 (% style="text-align:center" %) 253 253 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 254 254 255 -= ** RockwellPLC** =250 +== **2 Communication with Allen-Bradley CompactLogix L1769** == 256 256 257 -== **Communication with AB CompactLogix L1769** == 258 - 259 259 ((( 260 260 ((( 261 261 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. ... ... @@ -395,7 +395,7 @@ 395 395 396 396 ((( 397 397 ((( 398 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 391 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 399 399 ))) 400 400 401 401 ... ... @@ -422,7 +422,7 @@ 422 422 423 423 424 424 ((( 425 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 418 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 426 426 ))) 427 427 428 428 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -457,14 +457,6 @@ 457 457 458 458 ((( 459 459 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 460 - 461 - 462 -== **Allen-Bradley Ethernet DF1** == 463 - 464 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 465 - 466 - 467 -= **Siemens PLC** = 468 468 ))) 469 469 ))) 470 470 ... ... @@ -472,12 +472,14 @@ 472 472 473 473 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 474 474 460 +== **Allen-Bradley Ethernet DF1** == 461 + 462 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 463 + 475 475 == **Communication with S7-200 Smart** == 476 476 477 477 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 478 478 479 -= **Delta PLC** = 480 - 481 481 == **Delta DVP Ethernet** == 482 482 483 483 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -48.8 KB - Content