Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -101,22 +101,20 @@ 101 101 102 102 == **V-BOX and Wecon LX5V serial communication** == 103 103 104 -This example introduces the establishment of serial port communication between Wecon HMIand LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.104 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 105 105 106 106 **Software configuration of PLC** 107 107 108 108 **1)PLC programming software** 109 109 110 -[[image:image-2022081 0164710-1.png]]110 +[[image:image-20220822172553-1.png]] 111 111 112 - 113 113 **2)New PLC project** 114 114 115 115 Click New Project and select the PLC model. 116 116 117 -[[image:image-2022081 0172412-1.png]]116 +[[image:image-20220822172623-2.png]] 118 118 119 - 120 120 **3)Set Serial port parameters** 121 121 122 122 Follow the steps below to configure Serial port parameters ... ... @@ -129,27 +129,25 @@ 129 129 130 130 Parity:No verification 131 131 132 -[[image:image-2022081 0165759-3.png]]130 +[[image:image-20220822172657-3.png]] 133 133 134 - 135 135 **4)Registers list** 136 136 137 -[[image:image-202208 11102219-3.png]]134 +[[image:image-20220822172730-4.png]] 138 138 136 +**V-BOX software configuration** 139 139 140 -** HMIsoftwareconfiguration**138 +**1)V-BOX programming software** 141 141 142 - **1)HMIprogrammingsoftware**140 + [[image:image-20220824104124-1.png]] 143 143 144 - [[image:image-20220810171237-4.png]]142 +**2)V-NET add device** 145 145 146 - **2)NewHMIproject**144 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 147 147 148 - Click New Projectand select the HMImodel.146 +[[image:image-20220824104909-2.png]] 149 149 150 -[[image:image-20220810172010-5.png]] 151 151 152 - 153 153 **3)Set communication port parameters** 154 154 155 155 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -254,14 +254,52 @@ 254 254 255 255 = **Rockwell PLC** = 256 256 257 -== **Communication with AB CompactLogix L1769** == 258 258 254 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 255 + 256 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 257 + 258 +**HMI Settings** 259 + 260 +|**Item**|**Settings**|**Note** 261 +|Protocol|Allen-Bradlley MicroLogix| 262 +|Connection|RS232| 263 +|Baud rate|19200| 264 +|Data bit|8| 265 +|Parity|None| 266 +|Stop bit|1| 267 +|PLC station No.|1| 268 + 269 +**Address List** 270 + 271 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 272 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 273 +|O|O d.d|0.0~~255.15| 274 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 275 +|S|S d.d|0.0~~255.15| 276 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 277 +|(% rowspan="9" %)Word|S|S d|0~~255| 278 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 279 +|TP|TP nnhh|0~~ffff 280 +|CS|CS nnhh|0~~ffff 281 +|CP|CP nnhh|0~~ffff 282 +|N|N nnhh|0~~ffff 283 +|C|C nnhh|0~~ffff 284 +|T|T nnhh|0~~ffff 285 +|R|R nnhh|0~~ffff 286 + 287 +**Cable Wiring** 288 + 289 +[[image:image-20220824110724-1.png]] 290 + 291 + 292 + 293 +== **CompactLogix** == 294 + 259 259 ((( 260 260 ((( 261 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-BradleyL1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.297 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 262 262 ))) 263 - 264 - 265 265 ))) 266 266 267 267 (((
- image-20220822172553-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- image-20220822172623-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220822172657-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +141.6 KB - Content
- image-20220822172730-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +130.7 KB - Content
- image-20220824104124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.6 KB - Content
- image-20220824104909-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +278.8 KB - Content
- image-20220824110724-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content