Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 33.1
edited by Ben
on 2022/08/22 17:28
on 2022/08/22 17:28
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 7 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Ben1 +XWiki.Stone - Content
-
... ... @@ -1,5 +1,7 @@ 1 -= ** ModbusRTU** =1 += **1 General communication with PLC** = 2 2 3 +== **Modbus RTU** == 4 + 3 3 === **V-BOX as master** === 4 4 5 5 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -45,213 +45,19 @@ 45 45 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 46 |0F (Write multiple bits) 47 47 48 -= **WECON PLC** = 50 +== **WECON LX3V PLC** == 49 49 50 -= =**V-BOX和维控LX3V串行通信** ==52 +Select the protocol (% class="mark" %)"WECON LX3V" 51 51 52 - Supportedseries:WECONLX2V/LX2E/LX3V/LX3VP/LX3VE/LX3VM54 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC. 53 53 54 - **HMISettings**56 +(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN 55 55 56 -|**Item**|**Settings**|**Note** 57 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 58 -|Connection|RS422/RS485| 59 -|Baud rate|9600| 60 -|Data bit|7| 61 -|Parity|EVEN| 62 -|Stop bit|1| 63 -|PLC station No.|1| 64 - 65 -**Address List** 66 - 67 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 68 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 69 -|Y|Y|Y o|0~~303237| 70 -|M|M|M d|0~~99999| 71 -|T|T|T d|0~~99999| 72 -|C|C|C d|0~~99999| 73 -|S|S|S d|0~~99999| 74 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 -|Y|Y|Y o|0~~303237| 76 -|M|M|M d|0~~99999| 77 -|T|T|T d|0~~99999| 78 -|C|C|C d|0~~199| 79 -|D|D|D d|0~~7999| 80 -|S|S|S d|0~~99999| 81 -|SD|SD|SD d|8000~~9999| 82 - 83 -**Cable Wiring** 84 - 85 -* **RS485** 86 - 87 - [[image:image-20220822172124-1.png]] 88 - 89 -* **RS422** 90 - 91 - [[image:image-20220822172228-2.png]] 92 - 93 - 94 -**✎Note:** 95 - 96 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 97 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 98 - 99 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 100 - 101 - 102 -== **V-BOX and Wecon LX5V serial communication** == 103 - 104 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 105 - 106 -**Software configuration of PLC** 107 - 108 -**1)PLC programming software** 109 - 110 -[[image:image-20220822172553-1.png]] 111 - 112 -**2)New PLC project** 113 - 114 -Click New Project and select the PLC model. 115 - 116 -[[image:image-20220822172623-2.png]] 117 - 118 -**3)Set Serial port parameters** 119 - 120 -Follow the steps below to configure Serial port parameters 121 - 122 -Baud rate:115200 123 - 124 -Data bit:8 125 - 126 -Stop bit:1 127 - 128 -Parity:No verification 129 - 130 -[[image:image-20220822172657-3.png]] 131 - 132 -**4)Registers list** 133 - 134 -[[image:image-20220822172730-4.png]] 135 - 136 -**V-BOX software configuration** 137 - 138 -**1)HMI programming software** 139 - 140 - [[image:image-20220810171237-4.png]] 141 - 142 -**2)New HMI project** 143 - 144 -Click New Project and select the HMI model. 145 - 146 -[[image:image-20220810172010-5.png]] 147 - 148 - 149 -**3)Set communication port parameters** 150 - 151 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 152 - 153 -Baud rate:115200 154 - 155 -Data bit:8 156 - 157 -Stop bit:1 158 - 159 -Parity:No verification 160 - 161 -[[image:image-20220811104012-1.png]] 162 - 163 - 164 -**hardware connection** 165 - 166 -**1)Hardware wiring diagram** 167 - 168 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 169 - 170 - 171 - 172 -[[image:image-20220811103005-4.png]] 173 - 174 -[[image:image-20220811103227-7.png]] 175 - 176 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 177 - 178 -== **V-BOX and Wecon LX5V-N Ethernet communication** == 179 - 180 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 181 - 182 -**Software configuration of PLC** 183 - 184 -**1)PLC programming software** 185 - 186 -[[image:image-20220810164710-1.png]] 187 - 188 -**2)New PLC project** 189 - 190 -Click New Project and select the PLC model. 191 - 192 -[[image:image-20220811115454-1.png]] 193 - 194 -**3)Set Ethernet port parameters** 195 - 196 -Follow the steps below to configure Ethernet parameters 197 - 198 -PLC IP address:192.168.39.200 199 - 200 -default gateway:192.168.39.1 201 - 202 -subnet mask:255.255.255.0 203 - 204 -[[image:image-20220811140530-2.png]] 205 - 206 -**4)Registers list** 207 - 208 -[[image:image-20220811102219-3.png]] 209 - 210 -**HMI software configuration** 211 - 212 -**1)HMI programming software** 213 - 214 - [[image:image-20220810171237-4.png]] 215 - 216 -**2)New HMI project** 217 - 218 -Click New Project and select the HMI model. 219 - 220 -[[image:image-20220810172010-5.png]] 221 - 222 -**3)Set communication port parameters** 223 - 224 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 225 - 226 -HMI IP address:192.168.39.201 227 - 228 -default gateway:192.168.39.1 229 - 230 -subnet mask:255.255.255.0 231 - 232 -[[image:image-20220811170753-2.png]] 233 - 234 -Next, click Communication Settings to configure the IP of the HMI communication object. 235 - 236 -[[image:image-20220811163047-1.png]] 237 - 238 -**hardware connection** 239 - 240 -**1)Hardware wiring diagram** 241 - 242 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 243 - 244 -[[image:image-20220811170248-1.png]] 245 - 246 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 247 - 248 248 (% style="text-align:center" %) 249 249 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 250 250 251 -= ** RockwellPLC** =61 +== **2 Communication with Allen-Bradley CompactLogix L1769** == 252 252 253 -== **Communication with AB CompactLogix L1769** == 254 - 255 255 ((( 256 256 ((( 257 257 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. ... ... @@ -391,7 +391,7 @@ 391 391 392 392 ((( 393 393 ((( 394 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 202 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 395 395 ))) 396 396 397 397 ... ... @@ -418,7 +418,7 @@ 418 418 419 419 420 420 ((( 421 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 229 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 422 422 ))) 423 423 424 424 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -453,14 +453,6 @@ 453 453 454 454 ((( 455 455 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 456 - 457 - 458 -== **Allen-Bradley Ethernet DF1** == 459 - 460 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 461 - 462 - 463 -= **Siemens PLC** = 464 464 ))) 465 465 ))) 466 466 ... ... @@ -468,12 +468,14 @@ 468 468 469 469 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 470 470 271 +== **Allen-Bradley Ethernet DF1** == 272 + 273 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 274 + 471 471 == **Communication with S7-200 Smart** == 472 472 473 473 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 474 474 475 -= **Delta PLC** = 476 - 477 477 == **Delta DVP Ethernet** == 478 478 479 479 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -48.8 KB - Content
- image-20220822172553-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.9 KB - Content
- image-20220822172623-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -111.2 KB - Content
- image-20220822172657-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -141.6 KB - Content
- image-20220822172730-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -130.7 KB - Content