... ... @@ -135,15 +135,15 @@
135 135  
136 136  **V-BOX software configuration**
137 137  
138 -**1)V-BOX programming software**
138 +**1)HMI programming software**
139 139  
140 - [[image:image-20220824104124-1.png]]
140 + [[image:image-20220810171237-4.png]]
141 141  
142 -**2)V-NET add device**
142 +**2)New HMI project**
143 143  
144 -Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
144 +Click New Project and select the HMI model.
145 145  
146 -[[image:image-20220824104909-2.png]]
146 +[[image:image-20220810172010-5.png]]
147 147  
148 148  
149 149  **3)Set communication port parameters**
... ... @@ -250,51 +250,11 @@
250 250  
251 251  = **Rockwell PLC** =
252 252  
253 +== **Communication with AB CompactLogix L1769** ==
253 253  
254 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
255 -
256 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
257 -
258 -**HMI Settings**
259 -
260 -|**Item**|**Settings**|**Note**
261 -|Protocol|Allen-Bradlley MicroLogix|
262 -|Connection|RS232|
263 -|Baud rate|19200|
264 -|Data bit|8|
265 -|Parity|None|
266 -|Stop bit|1|
267 -|PLC station No.|1|
268 -
269 -**Address List**
270 -
271 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
272 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
273 -|O|O d.d|0.0~~255.15|
274 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
275 -|S|S d.d|0.0~~255.15|
276 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
277 -|(% rowspan="9" %)Word|S|S d|0~~255|
278 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
279 -|TP|TP nnhh|0~~ffff
280 -|CS|CS nnhh|0~~ffff
281 -|CP|CP nnhh|0~~ffff
282 -|N|N nnhh|0~~ffff
283 -|C|C nnhh|0~~ffff
284 -|T|T nnhh|0~~ffff
285 -|R|R nnhh|0~~ffff
286 -
287 -**Cable Wiring**
288 -
289 -[[image:image-20220824110724-1.png]]
290 -
291 -
292 -
293 -== **CompactLogix** ==
294 -
295 295  (((
296 296  (((
297 -This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
257 +This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
298 298  )))
299 299  
300 300  
... ... @@ -494,7 +494,6 @@
494 494  (((
495 495  The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
496 496  
497 -== ==
498 498  
499 499  == **Allen-Bradley Ethernet DF1** ==
500 500  
image-20220824104124-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -79.1 KB
Content