Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 4.1
edited by Leo
on 2022/06/16 17:20
Change comment: Renamed back-links.
To version 14.1
edited by Ben
on 2022/07/14 14:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -1 Communication with device
1 +1 Communication
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Leo
1 +XWiki.Ben
Content
... ... @@ -1,8 +1,8 @@
1 1  = **1 General communication with PLC** =
2 2  
3 -== **1.1 Modbus RTU** ==
3 +== **Modbus RTU** ==
4 4  
5 -==== V-Box as master: ====
5 +=== **V-BOX as master** ===
6 6  
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
8 8  
... ... @@ -9,9 +9,9 @@
9 9  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
10 10  
11 11  (% style="text-align:center" %)
12 -[[image:1624342015914-382.png||class="img-thumbnail" height="486" width="800"]]
12 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
13 13  
14 -==== V-Box as slave: ====
14 +=== **V-BOX as slave** ===
15 15  
16 16  Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
17 17  
... ... @@ -18,7 +18,7 @@
18 18  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
19 19  
20 20  (% style="text-align:center" %)
21 -[[image:1624348709622-711.png||queryString="width=809&height=493" class="img-thumbnail" height="488" width="800"]]
21 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
22 22  
23 23  **Address List**
24 24  
... ... @@ -47,7 +47,7 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -== **1.2 WECON LX3V PLC** ==
50 +== **WECON LX3V PLC** ==
51 51  
52 52  Select the protocol (% class="mark" %)"WECON LX3V"
53 53  
... ... @@ -56,33 +56,169 @@
56 56  (% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
57 57  
58 58  (% style="text-align:center" %)
59 -[[image:1624348978863-771.png||queryString="width=812&height=494" class="img-thumbnail" height="487" width="800"]]
59 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -== **1.3 Siemens S7-1200** ==
61 +== **2 Communication with Allen-Bradley CompactLogix L1769** ==
62 62  
63 +(((
64 +This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
65 +)))
66 +
67 +(((
68 +
69 +)))
70 +
71 +(((
72 +== **Software configuration of PLC** ==
73 +
74 +=== **PLC programming software** ===
75 +
76 + [[image:image-20220714113935-3.png]]
77 +
78 +=== **New PLC project** ===
79 +
80 +(((
81 +Click New Project and select the PLC model.
82 +)))
83 +
84 +(((
85 + [[image:image-20220714114247-4.png]]
86 +)))
87 +
88 +(((
89 + [[image:image-20220714114257-5.png]]
90 +)))
91 +
92 +(((
93 +
94 +)))
95 +
96 +(((
97 +=== **Set Ethernet parameters** ===
98 +
99 +(((
100 +Follow the steps below to configure Ethernet parameters
101 +)))
102 +
103 +(((
104 +PLC IP address:192.168.40.101
105 +)))
106 +
107 +(((
108 +default gateway:192.168.40.1
109 +)))
110 +
111 +(((
112 +subnet mask:255.255.255.0
113 +)))
114 +
115 +(((
116 + [[image:image-20220714115012-6.png]]
117 +)))
118 +
119 +(((
120 +
121 +)))
122 +
123 +(((
124 +== **V-box software configuration** ==
125 +
126 +=== **V-box programming software** ===
127 +
128 + [[image:image-20220714115214-7.png]]
129 +
130 +
131 +=== **Configure device network** ===
132 +
133 +(((
134 +Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
135 +)))
136 +
137 +(((
138 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
139 +)))
140 +
141 + [[image:image-20220714115440-9.png||height="425" width="791"]]
142 +)))
143 +)))
144 +
145 +== **V-net add device** ==
146 +)))
147 +
148 +(((
149 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
150 +)))
151 +
152 +(((
153 + [[image:image-20220714115640-10.png||height="430" width="797"]]
154 +)))
155 +
156 +(((
157 +
158 +)))
159 +
160 +(((
161 +=== **Set communication port parameters** ===
162 +
163 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
164 +
165 + [[image:image-20220714115848-11.png||height="432" width="802"]]
166 +)))
167 +
168 +
169 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
170 +
171 +[[image:image-20220714143820-1.png]]
172 +
173 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
174 +
175 +[[image:image-20220714143849-3.png]]
176 +
177 +
178 +== Engineering production ==
179 +
180 +
181 +== **Siemens S7-1200** ==
182 +
63 63  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
64 64  
65 -== **1.4 Allen-Bradley Ethernet DF1** ==
185 +== **Allen-Bradley Ethernet DF1** ==
66 66  
67 67  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
68 68  
69 -== **1.5 Communication with S7-200 Smart** ==
189 +== **Communication with S7-200 Smart** ==
70 70  
71 71  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
72 72  
73 -== **1.6 Delta DVP Ethernet** ==
193 +== **Delta DVP Ethernet** ==
74 74  
75 75  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
76 76  
77 -== **1.7 Delta DVP Serial Protocol** ==
197 +== **Delta DVP Serial Protocol** ==
78 78  
79 79  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
80 80  
201 +== **Communicate with Mitsubishi FX Series** ==
202 +
203 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
204 +
205 +== **Communicate with VB inverter** ==
206 +
207 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
208 +
209 +== **Omron CP1 Series** ==
210 +
211 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
212 +
213 +== **Omron CJ2M** ==
214 +
215 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
216 +
81 81  = **2 User define protocol** =
82 82  
83 83  More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
84 84  
85 -== **2.1 Read the temperature sensor.** ==
221 +== **Read the temperature sensor.** ==
86 86  
87 87  the commond format is as beliow:
88 88  
image-20220714113815-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +907.8 KB
Content
image-20220714113842-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.8 KB
Content
image-20220714113935-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.0 KB
Content
image-20220714114247-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714114257-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 MB
Content
image-20220714115012-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220714115214-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.0 MB
Content
image-20220714115308-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +718 bytes
Content
image-20220714115440-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220714115640-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714115848-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content