Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,54 +1,7 @@ 1 -= ** ModbusRTU** =1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = 2 2 3 -== =**V-BOXsmaster** ===3 +== **LX3V Serial Protocol** == 4 4 5 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 6 - 7 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 8 - 9 -(% style="text-align:center" %) 10 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 11 - 12 -=== **V-BOX as slave** === 13 - 14 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 15 - 16 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 17 - 18 -(% style="text-align:center" %) 19 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 20 - 21 -**Address List** 22 - 23 -(% class="table-bordered" %) 24 -|**Type**|**Register**|**Function code & Description** 25 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 26 -|06 (write single register: write a binary value to a holding register) 27 -|10 (write values to multiple addresses ) 28 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 29 -|06 (write single register: write a binary value to a holding register) 30 -|10 (write values to multiple addresses ) 31 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 32 -|06 (write single register: write a binary value to a holding register) 33 -|10 (write values to multiple addresses ) 34 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 35 -|10 (write values to multiple addresses ) 36 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 37 -|05 (Force a single coil to force the on/off state of a logic coil) 38 -|0F (Write multiple bits, ie write continuously) 39 -|(% rowspan="3" %)1|02 (Read the input state) 40 -|05 (Force a single coil to force the on/off state of a logic coil) 41 -|0F (Write multiple bits) 42 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 43 -|05 (Force a single coil to force the on/off state of a logic coil) 44 -|0F (Write multiple bits) 45 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 -|0F (Write multiple bits) 47 - 48 -= **WECON PLC** = 49 - 50 -== **V-BOX 和维控 LX3V 串行通信** == 51 - 52 52 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 53 53 54 54 **HMI Settings** ... ... @@ -82,25 +82,16 @@ 82 82 83 83 **Cable Wiring** 84 84 85 -* **RS485** 86 - 87 - [[image:image-20220822172124-1.png]] 88 - 89 89 * **RS422** 90 90 91 - 2172228-2.png]]40 + [[image:image-20220824120614-5.png]] 92 92 42 +* **RS485** 93 93 94 - **✎Note:**44 + [[image:image-20220824120524-3.png]] 95 95 96 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 97 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 46 +== **LX5V Serial Protocol** == 98 98 99 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 100 - 101 - 102 -== **V-BOX and Wecon LX5V serial communication** == 103 - 104 104 This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 105 105 106 106 **Software configuration of PLC** ... ... @@ -158,9 +158,8 @@ 158 158 159 159 Parity:No verification 160 160 161 -[[image:image-202208 11104012-1.png]]105 +[[image:image-20220824142130-1.png]] 162 162 163 - 164 164 **hardware connection** 165 165 166 166 **1)Hardware wiring diagram** ... ... @@ -167,15 +167,15 @@ 167 167 168 168 This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 169 169 113 +[[image:image-20220824142546-2.png]] 170 170 115 +[[image:image-20220824142643-3.png]] 171 171 172 -[[image:image-20220811103005-4.png]] 173 173 174 -[[image:image-20220811103227-7.png]] 175 175 176 176 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 177 177 178 -== ** V-BOX and WeconLX5V-N Ethernetcommunication** ==121 +== **LX5V-N Ethernet protocol** == 179 179 180 180 This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 181 181 ... ... @@ -250,9 +250,8 @@ 250 250 251 251 = **Rockwell PLC** = 252 252 196 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 253 253 254 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 255 - 256 256 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 257 257 258 258 **HMI Settings** ... ... @@ -290,7 +290,7 @@ 290 290 291 291 292 292 293 -== **CompactLogix** == 235 +== **CompactLogix Protocol** == 294 294 295 295 ((( 296 296 ((( ... ... @@ -490,7 +490,7 @@ 490 490 [[image:image-20220714162856-13.png]] 491 491 492 492 ((( 493 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-BradleyL1769 PLC.435 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 494 494 495 495 496 496 == **Allen-Bradley Ethernet DF1** == ... ... @@ -499,45 +499,96 @@ 499 499 500 500 501 501 = **Siemens PLC** = 444 + 445 +== **S7-200 Smart Ethernet Protocol** == 446 + 447 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 502 502 ))) 503 503 ))) 504 504 505 -== **S iemens S7-1200** ==451 +== **S7-1200 Ethernet Protocol** == 506 506 507 507 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 508 508 509 -= =**Communication withS7-200 Smart** ==455 += **Mitsubishi PLC** = 510 510 511 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]457 +== **Mitsubishi FX Series Protocol** == 512 512 459 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 460 + 513 513 = **Delta PLC** = 514 514 515 -== **D elta DVP Ethernet** ==463 +== **DVP Ethernet Protocol** == 516 516 517 517 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 518 518 519 -== **D elta DVP Serial Protocol** ==467 +== **DVP Serial Protocol** == 520 520 521 521 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 522 522 523 -= =**Communicatewith Mitsubishi FX Series** ==471 += **Omron PLC** = 524 524 525 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]473 +== **CP1 Series Protocol** == 526 526 527 - ==**CommunicatewithVB inverter** ==475 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 528 528 529 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]477 +== **CJ2M Series Protocol** == 530 530 531 - ==**OmronP1 Series** ==479 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 532 532 533 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]481 += **Modbus RTU** = 534 534 535 -== **Omr on CJ2M** ==483 +== **V-BOX as master** == 536 536 537 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]485 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 538 538 539 - =**2 Userdefineprotocol**=487 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 540 540 489 +(% style="text-align:center" %) 490 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 491 + 492 +== **V-BOX as slave** == 493 + 494 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 495 + 496 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 497 + 498 +(% style="text-align:center" %) 499 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 500 + 501 +**Address List** 502 + 503 +(% class="table-bordered" %) 504 +|**Type**|**Register**|**Function code & Description** 505 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 506 +|06 (write single register: write a binary value to a holding register) 507 +|10 (write values to multiple addresses ) 508 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 509 +|06 (write single register: write a binary value to a holding register) 510 +|10 (write values to multiple addresses ) 511 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 512 +|06 (write single register: write a binary value to a holding register) 513 +|10 (write values to multiple addresses ) 514 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 515 +|10 (write values to multiple addresses ) 516 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 517 +|05 (Force a single coil to force the on/off state of a logic coil) 518 +|0F (Write multiple bits, ie write continuously) 519 +|(% rowspan="3" %)1|02 (Read the input state) 520 +|05 (Force a single coil to force the on/off state of a logic coil) 521 +|0F (Write multiple bits) 522 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 523 +|05 (Force a single coil to force the on/off state of a logic coil) 524 +|0F (Write multiple bits) 525 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 526 +|0F (Write multiple bits) 527 + 528 +== **communicate with VB inverter** == 529 + 530 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 531 + 532 += **User define protocol** = 533 + 541 541 More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 542 542 543 543 == **Read the temperature sensor.** ==
- image-20220824120406-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.9 KB - Content
- image-20220824120507-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.3 KB - Content
- image-20220824120524-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- image-20220824120547-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.2 KB - Content
- image-20220824120614-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.9 KB - Content
- image-20220824142130-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.2 KB - Content
- image-20220824142546-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220824142643-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.3 KB - Content