Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 45.1
edited by Ben
on 2022/08/24 11:27
Change comment: There is no comment for this version
To version 54.1
edited by Ben
on 2022/08/24 11:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,52 +1,5 @@
1 -= **Modbus RTU** =
1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -=== **V-BOX as master** ===
4 -
5 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
6 -
7 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
8 -
9 -(% style="text-align:center" %)
10 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
11 -
12 -=== **V-BOX as slave** ===
13 -
14 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
15 -
16 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
17 -
18 -(% style="text-align:center" %)
19 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
20 -
21 -**Address List**
22 -
23 -(% class="table-bordered" %)
24 -|**Type**|**Register**|**Function code & Description**
25 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
26 -|06 (write single register: write a binary value to a holding register)
27 -|10 (write values to multiple addresses )
28 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
29 -|06 (write single register: write a binary value to a holding register)
30 -|10 (write values to multiple addresses )
31 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
32 -|06 (write single register: write a binary value to a holding register)
33 -|10 (write values to multiple addresses )
34 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
35 -|10 (write values to multiple addresses )
36 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
37 -|05 (Force a single coil to force the on/off state of a logic coil)
38 -|0F (Write multiple bits, ie write continuously)
39 -|(% rowspan="3" %)1|02 (Read the input state)
40 -|05 (Force a single coil to force the on/off state of a logic coil)
41 -|0F (Write multiple bits)
42 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
43 -|05 (Force a single coil to force the on/off state of a logic coil)
44 -|0F (Write multiple bits)
45 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
46 -|0F (Write multiple bits)
47 -
48 -= **WECON PLC** =
49 -
50 50  == **LX3V 串行通信** ==
51 51  
52 52  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
... ... @@ -249,7 +249,6 @@
249 249  
250 250  = **Rockwell PLC** =
251 251  
252 -
253 253  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
254 254  
255 255  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -519,14 +519,14 @@
519 519  
520 520  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
521 521  
474 += **Mitsubishi PLC** =
475 +
522 522  == **Communicate with Mitsubishi FX Series** ==
523 523  
524 524  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
525 525  
526 -== **Communicate with VB inverter** ==
480 += **Omron PLC** =
527 527  
528 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
529 -
530 530  == **Omron CP1 Series** ==
531 531  
532 532  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
... ... @@ -535,8 +535,59 @@
535 535  
536 536  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
537 537  
538 -= **2 User define protocol** =
490 += **Modbus RTU** =
539 539  
492 +== **V-BOX as master** ==
493 +
494 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
495 +
496 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
497 +
498 +(% style="text-align:center" %)
499 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
500 +
501 +== **V-BOX as slave** ==
502 +
503 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
504 +
505 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
506 +
507 +(% style="text-align:center" %)
508 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
509 +
510 +**Address List**
511 +
512 +(% class="table-bordered" %)
513 +|**Type**|**Register**|**Function code & Description**
514 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
515 +|06 (write single register: write a binary value to a holding register)
516 +|10 (write values to multiple addresses )
517 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
518 +|06 (write single register: write a binary value to a holding register)
519 +|10 (write values to multiple addresses )
520 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
521 +|06 (write single register: write a binary value to a holding register)
522 +|10 (write values to multiple addresses )
523 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
524 +|10 (write values to multiple addresses )
525 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
526 +|05 (Force a single coil to force the on/off state of a logic coil)
527 +|0F (Write multiple bits, ie write continuously)
528 +|(% rowspan="3" %)1|02 (Read the input state)
529 +|05 (Force a single coil to force the on/off state of a logic coil)
530 +|0F (Write multiple bits)
531 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
532 +|05 (Force a single coil to force the on/off state of a logic coil)
533 +|0F (Write multiple bits)
534 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
535 +|0F (Write multiple bits)
536 +
537 +== **V-BOX communicate with VB inverter** ==
538 +
539 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
540 +
541 += **User define protocol** =
542 +
540 540  More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
541 541  
542 542  == **Read the temperature sensor.** ==