Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 13 added, 0 removed)
- image-20220824120406-1.png
- image-20220824120507-2.png
- image-20220824120524-3.png
- image-20220824120547-4.png
- image-20220824120614-5.png
- image-20220824142130-1.png
- image-20220824142546-2.png
- image-20220824142643-3.png
- image-20220824142722-1.png
- image-20220824143613-1.png
- image-20220824143744-2.png
- image-20220824144619-1.png
- image-20220824151127-2.png
Details
- Page properties
-
- Content
-
... ... @@ -1,54 +1,7 @@ 1 -= ** ModbusRTU** =1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = 2 2 3 -== =**V-BOXsmaster** ===3 +== **LX3V Serial Protocol** == 4 4 5 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 6 - 7 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 8 - 9 -(% style="text-align:center" %) 10 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 11 - 12 -=== **V-BOX as slave** === 13 - 14 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 15 - 16 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 17 - 18 -(% style="text-align:center" %) 19 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 20 - 21 -**Address List** 22 - 23 -(% class="table-bordered" %) 24 -|**Type**|**Register**|**Function code & Description** 25 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 26 -|06 (write single register: write a binary value to a holding register) 27 -|10 (write values to multiple addresses ) 28 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 29 -|06 (write single register: write a binary value to a holding register) 30 -|10 (write values to multiple addresses ) 31 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 32 -|06 (write single register: write a binary value to a holding register) 33 -|10 (write values to multiple addresses ) 34 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 35 -|10 (write values to multiple addresses ) 36 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 37 -|05 (Force a single coil to force the on/off state of a logic coil) 38 -|0F (Write multiple bits, ie write continuously) 39 -|(% rowspan="3" %)1|02 (Read the input state) 40 -|05 (Force a single coil to force the on/off state of a logic coil) 41 -|0F (Write multiple bits) 42 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 43 -|05 (Force a single coil to force the on/off state of a logic coil) 44 -|0F (Write multiple bits) 45 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 -|0F (Write multiple bits) 47 - 48 -= **WECON PLC** = 49 - 50 -== **LX3V 串行通信** == 51 - 52 52 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 53 53 54 54 **HMI Settings** ... ... @@ -82,24 +82,16 @@ 82 82 83 83 **Cable Wiring** 84 84 85 -* **RS485** 86 - 87 - [[image:image-20220822172124-1.png]] 88 - 89 89 * **RS422** 90 90 91 - 2172228-2.png]]40 + [[image:image-20220824120614-5.png]] 92 92 42 +* **RS485** 93 93 94 - **✎Note:**44 + [[image:image-20220824120524-3.png]] 95 95 96 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 97 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 46 +== **LX5V Serial Protocol** == 98 98 99 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 100 - 101 -== **LX5V serial communication** == 102 - 103 103 This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 104 104 105 105 **Software configuration of PLC** ... ... @@ -106,7 +106,7 @@ 106 106 107 107 **1)PLC programming software** 108 108 109 -[[image:image-2022082 2172553-1.png]]54 +[[image:image-20220824142722-1.png]] 110 110 111 111 **2)New PLC project** 112 112 ... ... @@ -157,38 +157,33 @@ 157 157 158 158 Parity:No verification 159 159 160 -[[image:image-202208 11104012-1.png]]105 +[[image:image-20220824142130-1.png]] 161 161 162 - 163 163 **hardware connection** 164 164 165 165 **1)Hardware wiring diagram** 166 166 167 - This examplentroduces WeconHMI with LX5V PLC to establish communication through serial port.The connection diagram is as follows:111 +[[image:image-20220824142546-2.png]] 168 168 113 +[[image:image-20220824142643-3.png]] 169 169 115 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 170 170 171 - [[image:image-20220811103005-4.png]]117 +== **LX5V-N Ethernet protocol** == 172 172 173 - [[image:image-20220811103227-7.png]]119 +This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 174 174 175 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 176 - 177 -== **LX5V-N Ethernet communication** == 178 - 179 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 180 - 181 181 **Software configuration of PLC** 182 182 183 183 **1)PLC programming software** 184 184 185 -[[image:image-2022081 0164710-1.png]]125 +[[image:image-20220824142722-1.png]] 186 186 187 187 **2)New PLC project** 188 188 189 189 Click New Project and select the PLC model. 190 190 191 -[[image:image-2022081 1115454-1.png]]131 +[[image:image-20220824143613-1.png]] 192 192 193 193 **3)Set Ethernet port parameters** 194 194 ... ... @@ -200,56 +200,46 @@ 200 200 201 201 subnet mask:255.255.255.0 202 202 203 -[[image:image-2022081 1140530-2.png]]143 +[[image:image-20220824143744-2.png]] 204 204 145 + 205 205 **4)Registers list** 206 206 207 -[[image:image-202208 11102219-3.png]]148 +[[image:image-20220822172730-4.png]] 208 208 209 -** HMIsoftware configuration**150 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** 210 210 211 -**1) HMIprogramming software**152 +**1)V-BOX programming software** 212 212 213 - [[image:image-202208101 71237-4.png]]154 + [[image:image-20220824104124-1.png]] 214 214 215 -**2)N ewHMIproject**156 +**2)V-NET add device** 216 216 217 - ClickNewProject andselect theHMImodel.158 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 218 218 219 -[[image:image-202208 10172010-5.png]]160 +[[image:image-20220824104909-2.png]] 220 220 221 221 **3)Set communication port parameters** 222 222 223 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 224 224 225 - HMIIP address:192.168.39.201165 +Click Communication to configure the LX5V plc protocol and IP address. 226 226 227 - defaultgateway:192.168.39.1167 +[[image:image-20220824144619-1.png]] 228 228 229 -subnet mask:255.255.255.0 230 - 231 -[[image:image-20220811170753-2.png]] 232 - 233 -Next, click Communication Settings to configure the IP of the HMI communication object. 234 - 235 -[[image:image-20220811163047-1.png]] 236 - 237 237 **hardware connection** 238 238 239 239 **1)Hardware wiring diagram** 240 240 241 -This example introduces WeconHMIwith LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:173 +This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 242 242 243 -[[image:image-202208111 70248-1.png]]175 +[[image:image-20220824151127-2.png]] 244 244 245 -The above are all the steps for establishing ethernet communication between WeconHMIwith LX5V PLC.177 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 246 246 247 -(% style="text-align:center" %) 248 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 249 249 250 250 = **Rockwell PLC** = 251 251 252 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 182 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 253 253 254 254 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 255 255 ... ... @@ -288,7 +288,7 @@ 288 288 289 289 290 290 291 -== **CompactLogix** == 221 +== **CompactLogix Protocol** == 292 292 293 293 ((( 294 294 ((( ... ... @@ -497,49 +497,96 @@ 497 497 498 498 499 499 = **Siemens PLC** = 430 + 431 +== **S7-200 Smart Ethernet Protocol** == 432 + 433 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 500 500 ))) 501 501 ))) 502 502 503 -== **S iemens S7-1200** ==437 +== **S7-1200 Ethernet Protocol** == 504 504 505 505 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 506 506 507 -= =**Communication withS7-200 Smart** ==441 += **Mitsubishi PLC** = 508 508 509 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]443 +== **Mitsubishi FX Series Protocol** == 510 510 445 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 446 + 511 511 = **Delta PLC** = 512 512 513 -== **D elta DVP Ethernet** ==449 +== **DVP Ethernet Protocol** == 514 514 515 515 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 516 516 517 -== **D elta DVP Serial Protocol** ==453 +== **DVP Serial Protocol** == 518 518 519 519 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 520 520 521 -= ** MitsubishiPLC** =457 += **Omron PLC** = 522 522 523 -== **C ommunicatewith Mitsubishi FXSeries** ==459 +== **CP1 Series Protocol** == 524 524 525 -[[download link>> url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]461 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 526 526 527 -== **C ommunicatewith VB inverter** ==463 +== **CJ2M Series Protocol** == 528 528 529 -[[download link>> url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]465 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 530 530 531 -= ** OmronPLC** =467 += **Modbus RTU** = 532 532 533 -== **O mronCP1Series** ==469 +== **V-BOX as master** == 534 534 535 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]471 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 536 536 537 - ==**OmronCJ2M**==473 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 538 538 539 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 475 +(% style="text-align:center" %) 476 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 540 540 541 -= ** 2Userdefine protocol** =478 +== **V-BOX as slave** == 542 542 480 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 481 + 482 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 483 + 484 +(% style="text-align:center" %) 485 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 486 + 487 +**Address List** 488 + 489 +(% class="table-bordered" %) 490 +|**Type**|**Register**|**Function code & Description** 491 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 492 +|06 (write single register: write a binary value to a holding register) 493 +|10 (write values to multiple addresses ) 494 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 495 +|06 (write single register: write a binary value to a holding register) 496 +|10 (write values to multiple addresses ) 497 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 498 +|06 (write single register: write a binary value to a holding register) 499 +|10 (write values to multiple addresses ) 500 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 501 +|10 (write values to multiple addresses ) 502 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 503 +|05 (Force a single coil to force the on/off state of a logic coil) 504 +|0F (Write multiple bits, ie write continuously) 505 +|(% rowspan="3" %)1|02 (Read the input state) 506 +|05 (Force a single coil to force the on/off state of a logic coil) 507 +|0F (Write multiple bits) 508 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 509 +|05 (Force a single coil to force the on/off state of a logic coil) 510 +|0F (Write multiple bits) 511 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 512 +|0F (Write multiple bits) 513 + 514 +== **communicate with VB inverter** == 515 + 516 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 517 + 518 += **User define protocol** = 519 + 543 543 More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 544 544 545 545 == **Read the temperature sensor.** ==
- image-20220824120406-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.9 KB - Content
- image-20220824120507-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.3 KB - Content
- image-20220824120524-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- image-20220824120547-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.2 KB - Content
- image-20220824120614-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.9 KB - Content
- image-20220824142130-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.2 KB - Content
- image-20220824142546-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220824142643-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.3 KB - Content
- image-20220824142722-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- image-20220824143613-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +206.2 KB - Content
- image-20220824143744-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824144619-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.2 KB - Content
- image-20220824151127-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.5 KB - Content