Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 5.1
edited by Leo
on 2022/06/16 17:21
Change comment: Renamed from xwiki:V-BOX.V-Net.Training.1\.Communication.WebHome
To version 30.1
edited by Ben
on 2022/08/22 17:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -1 Communication with device
1 +1 Communication
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Leo
1 +XWiki.Ben
Content
... ... @@ -1,17 +1,15 @@
1 -= **1 General communication with PLC** =
1 += **Modbus RTU** =
2 2  
3 -== **1.1 Modbus RTU** ==
3 +=== **V-BOX as master** ===
4 4  
5 -==== V-Box as master: ====
6 -
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
8 8  
9 9  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
10 10  
11 11  (% style="text-align:center" %)
12 -[[image:1624342015914-382.png||class="img-thumbnail" height="486" width="800"]]
10 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
13 13  
14 -==== V-Box as slave: ====
12 +=== **V-BOX as slave** ===
15 15  
16 16  Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
17 17  
... ... @@ -18,7 +18,7 @@
18 18  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
19 19  
20 20  (% style="text-align:center" %)
21 -[[image:1624348709622-711.png||queryString="width=809&height=493" class="img-thumbnail" height="488" width="800"]]
19 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
22 22  
23 23  **Address List**
24 24  
... ... @@ -47,42 +47,466 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -== **1.2 WECON LX3V PLC** ==
48 += **WECON PLC** =
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
50 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
52 +**HMI Settings**
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
54 +|**Item**|**Settings**|**Note**
55 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
56 +|Connection|RS422/RS485|
57 +|Baud rate|9600|
58 +|Data bit|7|
59 +|Parity|EVEN|
60 +|Stop bit|1|
61 +|PLC station No.|1|
57 57  
63 +**Address List**
64 +
65 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
66 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
67 +|Y|Y|Y o|0~~303237|
68 +|M|M|M d|0~~99999|
69 +|T|T|T d|0~~99999|
70 +|C|C|C d|0~~99999|
71 +|S|S|S d|0~~99999|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 +|Y|Y|Y o|0~~303237|
74 +|M|M|M d|0~~99999|
75 +|T|T|T d|0~~99999|
76 +|C|C|C d|0~~199|
77 +|D|D|D d|0~~7999|
78 +|S|S|S d|0~~99999|
79 +|SD|SD|SD d|8000~~9999|
80 +
81 +**Cable Wiring**
82 +
83 +* **RS485**
84 +
85 + [[image:image-20220822172124-1.png]]
86 +
87 +* **RS422**
88 +
89 + [[image:image-20220822172228-2.png]]
90 +
91 +
92 +**✎Note:**
93 +
94 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
95 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
96 +
97 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
98 +
99 +
100 +== **V-BOX and Wecon LX5V serial communication** ==
101 +
102 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
103 +
104 +**Software configuration of PLC**
105 +
106 +**1)PLC programming software**
107 +
108 +[[image:image-20220810164710-1.png]]
109 +
110 +
111 +**2)New PLC project**
112 +
113 +Click New Project and select the PLC model.
114 +
115 +[[image:image-20220810172412-1.png]]
116 +
117 +
118 +**3)Set Serial port parameters**
119 +
120 +Follow the steps below to configure Serial port parameters
121 +
122 +Baud rate:115200
123 +
124 +Data bit:8
125 +
126 +Stop bit:1
127 +
128 +Parity:No verification
129 +
130 +[[image:image-20220810165759-3.png]]
131 +
132 +
133 +**4)Registers list**
134 +
135 +[[image:image-20220811102219-3.png]]
136 +
137 +
138 +**HMI software configuration**
139 +
140 +**1)HMI programming software**
141 +
142 + [[image:image-20220810171237-4.png]]
143 +
144 +**2)New HMI project**
145 +
146 +Click New Project and select the HMI model.
147 +
148 +[[image:image-20220810172010-5.png]]
149 +
150 +
151 +**3)Set communication port parameters**
152 +
153 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
154 +
155 +Baud rate:115200
156 +
157 +Data bit:8
158 +
159 +Stop bit:1
160 +
161 +Parity:No verification
162 +
163 +[[image:image-20220811104012-1.png]]
164 +
165 +
166 +**hardware connection**
167 +
168 +**1)Hardware wiring diagram**
169 +
170 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
171 +
172 +
173 +
174 +[[image:image-20220811103005-4.png]]
175 +
176 +[[image:image-20220811103227-7.png]]
177 +
178 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
179 +
180 +== **HMI and Wecon LX5V-N Ethernet communication** ==
181 +
182 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
183 +
184 +**Software configuration of PLC**
185 +
186 +**1)PLC programming software**
187 +
188 +[[image:image-20220810164710-1.png]]
189 +
190 +**2)New PLC project**
191 +
192 +Click New Project and select the PLC model.
193 +
194 +[[image:image-20220811115454-1.png]]
195 +
196 +**3)Set Ethernet port parameters**
197 +
198 +Follow the steps below to configure Ethernet parameters
199 +
200 +PLC IP address:192.168.39.200
201 +
202 +default gateway:192.168.39.1
203 +
204 +subnet mask:255.255.255.0
205 +
206 +[[image:image-20220811140530-2.png]]
207 +
208 +**4)Registers list**
209 +
210 +[[image:image-20220811102219-3.png]]
211 +
212 +**HMI software configuration**
213 +
214 +**1)HMI programming software**
215 +
216 + [[image:image-20220810171237-4.png]]
217 +
218 +**2)New HMI project**
219 +
220 +Click New Project and select the HMI model.
221 +
222 +[[image:image-20220810172010-5.png]]
223 +
224 +**3)Set communication port parameters**
225 +
226 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
227 +
228 +HMI IP address:192.168.39.201
229 +
230 +default gateway:192.168.39.1
231 +
232 +subnet mask:255.255.255.0
233 +
234 +[[image:image-20220811170753-2.png]]
235 +
236 +Next, click Communication Settings to configure the IP of the HMI communication object.
237 +
238 +[[image:image-20220811163047-1.png]]
239 +
240 +**hardware connection**
241 +
242 +**1)Hardware wiring diagram**
243 +
244 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
245 +
246 +[[image:image-20220811170248-1.png]]
247 +
248 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
249 +
58 58  (% style="text-align:center" %)
59 -[[image:1624348978863-771.png||queryString="width=812&height=494" class="img-thumbnail" height="487" width="800"]]
251 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -== **1.3 Siemens S7-1200** ==
253 += **Rockwell PLC** =
62 62  
63 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
255 +== **Communication with AB CompactLogix L1769** ==
64 64  
65 -== **1.4 Allen-Bradley Ethernet DF1** ==
257 +(((
258 +(((
259 +This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
260 +)))
66 66  
262 +
263 +)))
264 +
265 +(((
266 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
267 +(((
268 +**Software configuration of PLC**
269 +)))
270 +
271 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
272 +(((
273 +**1)PLC programming software**
274 +)))
275 +
276 +[[image:image-20220714162600-1.png]]
277 +
278 +(% class="wikigeneratedid" id="HNewPLCproject" %)
279 +(((
280 +**2)New PLC project**
281 +)))
282 +
283 +(((
284 +(((
285 +Click New Project and select the PLC model.
286 +)))
287 +)))
288 +
289 +(((
290 +[[image:image-20220714162617-2.png]]
291 +)))
292 +
293 +(((
294 +
295 +
296 +[[image:image-20220714162652-4.png]]
297 +)))
298 +
299 +(((
300 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
301 +(((
302 +**3)Set Ethernet parameters**
303 +)))
304 +
305 +(((
306 +(((
307 +(((
308 +Follow the steps below to configure Ethernet parameters
309 +)))
310 +)))
311 +)))
312 +
313 +(((
314 +(((
315 +(((
316 +PLC IP address:192.168.40.101
317 +)))
318 +)))
319 +)))
320 +
321 +(((
322 +(((
323 +(((
324 +default gateway:192.168.40.1
325 +)))
326 +)))
327 +)))
328 +
329 +(((
330 +(((
331 +(((
332 +subnet mask:255.255.255.0
333 +)))
334 +)))
335 +)))
336 +
337 +(((
338 +[[image:image-20220714162713-5.png]]
339 +)))
340 +
341 +(((
342 +
343 +)))
344 +
345 +(((
346 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
347 +(((
348 +**V-box software configuration**
349 +)))
350 +
351 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
352 +(((
353 +**1)V-box programming software**
354 +)))
355 +
356 +(% class="wikigeneratedid" %)
357 +(((
358 + [[image:image-20220714162725-6.png]]
359 +)))
360 +
361 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
362 +(((
363 +**2)Configure device network**
364 +)))
365 +
366 +(((
367 +(((
368 +(((
369 +Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
370 +)))
371 +
372 +(((
373 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
374 +)))
375 +)))
376 +)))
377 +
378 +(((
379 +(((
380 +[[image:image-20220714162737-7.png]]
381 +
382 +
383 +)))
384 +)))
385 +)))
386 +)))
387 +
388 +(% class="wikigeneratedid" id="HV-netadddevice" %)
389 +(((
390 +**3)V-net add device**
391 +)))
392 +)))
393 +
394 +(((
395 +(((
396 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
397 +)))
398 +
399 +
400 +)))
401 +
402 +(((
403 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
404 +(((
405 +**4)Set communication port parameters**
406 +)))
407 +
408 +(((
409 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
410 +)))
411 +
412 +[[image:image-20220714162805-9.png]]
413 +)))
414 +
415 +(((
416 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
417 +)))
418 +
419 +[[image:image-20220714162814-10.png]]
420 +
421 +
422 +(((
423 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
424 +)))
425 +
426 +(% class="wikigeneratedid" id="HEngineeringproduction" %)
427 +(((
428 +**5)Engineering production**
429 +)))
430 +
431 +(% class="wikigeneratedid" %)
432 +(((
433 +(((
434 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
435 +)))
436 +
437 +[[image:image-20220714162841-12.png]]
438 +
439 +
440 +(((
441 +**hardware connection**
442 +)))
443 +)))
444 +
445 +(((
446 +**1)Hardware wiring diagram**
447 +)))
448 +
449 +(((
450 +(((
451 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
452 +)))
453 +
454 +[[image:image-20220714162856-13.png]]
455 +
456 +(((
457 +The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
458 +
459 +
460 +== **Allen-Bradley Ethernet DF1** ==
461 +
67 67  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
68 68  
69 -== **1.5 Communication with S7-200 Smart** ==
70 70  
465 += **Siemens PLC** =
466 +)))
467 +)))
468 +
469 +== **Siemens S7-1200** ==
470 +
471 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
472 +
473 +== **Communication with S7-200 Smart** ==
474 +
71 71  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
72 72  
73 -== **1.6 Delta DVP Ethernet** ==
477 += **Delta PLC** =
74 74  
479 +== **Delta DVP Ethernet** ==
480 +
75 75  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
76 76  
77 -== **1.7 Delta DVP Serial Protocol** ==
483 +== **Delta DVP Serial Protocol** ==
78 78  
79 79  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
80 80  
487 +== **Communicate with Mitsubishi FX Series** ==
488 +
489 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
490 +
491 +== **Communicate with VB inverter** ==
492 +
493 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
494 +
495 +== **Omron CP1 Series** ==
496 +
497 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
498 +
499 +== **Omron CJ2M** ==
500 +
501 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
502 +
81 81  = **2 User define protocol** =
82 82  
83 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
505 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
84 84  
85 -== **2.1 Read the temperature sensor.** ==
507 +== **Read the temperature sensor.** ==
86 86  
87 87  the commond format is as beliow:
88 88  
image-20220714113815-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +907.8 KB
Content
image-20220714113842-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.8 KB
Content
image-20220714113935-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.0 KB
Content
image-20220714114247-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714114257-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 MB
Content
image-20220714115012-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220714115214-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.0 MB
Content
image-20220714115308-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +718 bytes
Content
image-20220714115440-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220714115640-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714115848-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content