Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,54 @@ 1 -= (% style="color:inherit; font-family:inherit" %)**WECONPLC**(%%)=1 += **Modbus RTU** = 2 2 3 -== ** LX3V串行通信** ==3 +=== **V-BOX as master** === 4 4 5 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 6 + 7 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 8 + 9 +(% style="text-align:center" %) 10 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 11 + 12 +=== **V-BOX as slave** === 13 + 14 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 15 + 16 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 17 + 18 +(% style="text-align:center" %) 19 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 20 + 21 +**Address List** 22 + 23 +(% class="table-bordered" %) 24 +|**Type**|**Register**|**Function code & Description** 25 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 26 +|06 (write single register: write a binary value to a holding register) 27 +|10 (write values to multiple addresses ) 28 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 29 +|06 (write single register: write a binary value to a holding register) 30 +|10 (write values to multiple addresses ) 31 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 32 +|06 (write single register: write a binary value to a holding register) 33 +|10 (write values to multiple addresses ) 34 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 35 +|10 (write values to multiple addresses ) 36 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 37 +|05 (Force a single coil to force the on/off state of a logic coil) 38 +|0F (Write multiple bits, ie write continuously) 39 +|(% rowspan="3" %)1|02 (Read the input state) 40 +|05 (Force a single coil to force the on/off state of a logic coil) 41 +|0F (Write multiple bits) 42 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 43 +|05 (Force a single coil to force the on/off state of a logic coil) 44 +|0F (Write multiple bits) 45 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 +|0F (Write multiple bits) 47 + 48 += **WECON PLC** = 49 + 50 +== **V-BOX 和维控 LX3V 串行通信** == 51 + 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 7 **HMI Settings** ... ... @@ -51,8 +51,9 @@ 51 51 52 52 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 53 53 54 -== **LX5V serial communication** == 55 55 102 +== **V-BOX and Wecon LX5V serial communication** == 103 + 56 56 This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 57 57 58 58 **Software configuration of PLC** ... ... @@ -127,7 +127,7 @@ 127 127 128 128 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 129 129 130 -== **LX5V-N Ethernet communication** == 178 +== **V-BOX and Wecon LX5V-N Ethernet communication** == 131 131 132 132 This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 133 133 ... ... @@ -202,6 +202,7 @@ 202 202 203 203 = **Rockwell PLC** = 204 204 253 + 205 205 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 206 206 207 207 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -471,14 +471,14 @@ 471 471 472 472 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 473 473 474 -= **Mitsubishi PLC** = 475 - 476 476 == **Communicate with Mitsubishi FX Series** == 477 477 478 478 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 479 479 480 -= ** OmronPLC** =527 +== **Communicate with VB inverter** == 481 481 529 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 530 + 482 482 == **Omron CP1 Series** == 483 483 484 484 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] ... ... @@ -487,59 +487,8 @@ 487 487 488 488 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 489 489 490 -= ** ModbusRTU** =539 += **2 User define protocol** = 491 491 492 -=== **V-BOX as master** === 493 - 494 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 495 - 496 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 497 - 498 -(% style="text-align:center" %) 499 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 500 - 501 -=== **V-BOX as slave** === 502 - 503 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 504 - 505 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 506 - 507 -(% style="text-align:center" %) 508 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 509 - 510 -**Address List** 511 - 512 -(% class="table-bordered" %) 513 -|**Type**|**Register**|**Function code & Description** 514 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 515 -|06 (write single register: write a binary value to a holding register) 516 -|10 (write values to multiple addresses ) 517 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 518 -|06 (write single register: write a binary value to a holding register) 519 -|10 (write values to multiple addresses ) 520 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 521 -|06 (write single register: write a binary value to a holding register) 522 -|10 (write values to multiple addresses ) 523 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 524 -|10 (write values to multiple addresses ) 525 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 526 -|05 (Force a single coil to force the on/off state of a logic coil) 527 -|0F (Write multiple bits, ie write continuously) 528 -|(% rowspan="3" %)1|02 (Read the input state) 529 -|05 (Force a single coil to force the on/off state of a logic coil) 530 -|0F (Write multiple bits) 531 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 532 -|05 (Force a single coil to force the on/off state of a logic coil) 533 -|0F (Write multiple bits) 534 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 535 -|0F (Write multiple bits) 536 - 537 -== **Communicate with VB inverter** == 538 - 539 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 540 - 541 -= **User define protocol** = 542 - 543 543 More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 544 544 545 545 == **Read the temperature sensor.** ==