Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 53.1
edited by Ben
on 2022/08/24 11:35
Change comment: There is no comment for this version
To version 78.1
edited by Ben
on 2022/08/24 15:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,6 @@
1 1  = (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **LX3V 串行通信** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -35,24 +35,16 @@
35 35  
36 36  **Cable Wiring**
37 37  
38 -* **RS485**
39 -
40 - [[image:image-20220822172124-1.png]]
41 -
42 42  * **RS422**
43 43  
44 - [[image:image-20220822172228-2.png]]
40 + [[image:image-20220824120614-5.png]]
45 45  
42 +* **RS485**
46 46  
47 -**✎Note:**
44 + [[image:image-20220824120524-3.png]]
48 48  
49 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
50 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
46 +== **LX5V Serial Protocol** ==
51 51  
52 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
53 -
54 -== **LX5V serial communication** ==
55 -
56 56  This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
57 57  
58 58  **Software configuration of PLC**
... ... @@ -59,7 +59,7 @@
59 59  
60 60  **1)PLC programming software**
61 61  
62 -[[image:image-20220822172553-1.png]]
54 +[[image:image-20220824142722-1.png]]
63 63  
64 64  **2)New PLC project**
65 65  
... ... @@ -110,38 +110,33 @@
110 110  
111 111  Parity:No verification
112 112  
113 -[[image:image-20220811104012-1.png]]
105 +[[image:image-20220824142130-1.png]]
114 114  
115 -
116 116  **hardware connection**
117 117  
118 118  **1)Hardware wiring diagram**
119 119  
120 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
111 +[[image:image-20220824142546-2.png]]
121 121  
113 +[[image:image-20220824142643-3.png]]
122 122  
115 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
123 123  
124 -[[image:image-20220811103005-4.png]]
117 +== **LX5V-N Ethernet protocol** ==
125 125  
126 -[[image:image-20220811103227-7.png]]
119 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
127 127  
128 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
129 -
130 -== **LX5V-N Ethernet communication** ==
131 -
132 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
133 -
134 134  **Software configuration of PLC**
135 135  
136 136  **1)PLC programming software**
137 137  
138 -[[image:image-20220810164710-1.png]]
125 +[[image:image-20220824142722-1.png]]
139 139  
140 140  **2)New PLC project**
141 141  
142 142  Click New Project and select the PLC model.
143 143  
144 -[[image:image-20220811115454-1.png]]
131 +[[image:image-20220824143613-1.png]]
145 145  
146 146  **3)Set Ethernet port parameters**
147 147  
... ... @@ -153,56 +153,41 @@
153 153  
154 154  subnet mask:255.255.255.0
155 155  
156 -[[image:image-20220811140530-2.png]]
143 +[[image:image-20220824143744-2.png]]
157 157  
158 158  **4)Registers list**
159 159  
160 -[[image:image-20220811102219-3.png]]
147 +[[image:image-20220822172730-4.png]]
161 161  
162 -**HMI software configuration**
149 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
163 163  
164 -**1)HMI programming software**
151 +**1)V-BOX programming software**
165 165  
166 - [[image:image-20220810171237-4.png]]
153 + [[image:image-20220824104124-1.png]]
167 167  
168 -**2)New HMI project**
155 +**2)V-NET add device**
169 169  
170 -Click New Project and select the HMI model.
157 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
171 171  
172 -[[image:image-20220810172010-5.png]]
159 +[[image:image-20220824104909-2.png]]
173 173  
174 174  **3)Set communication port parameters**
175 175  
176 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
163 +Click Communication to configure the LX5V plc protocol and IP address.
177 177  
178 -HMI IP address:192.168.39.201
165 +[[image:image-20220824144619-1.png]]
179 179  
180 -default gateway:192.168.39.1
181 -
182 -subnet mask:255.255.255.0
183 -
184 -[[image:image-20220811170753-2.png]]
185 -
186 -Next, click Communication Settings to configure the IP of the HMI communication object.
187 -
188 -[[image:image-20220811163047-1.png]]
189 -
190 190  **hardware connection**
191 191  
192 192  **1)Hardware wiring diagram**
193 193  
194 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
171 +[[image:image-20220824151127-2.png]]
195 195  
196 -[[image:image-20220811170248-1.png]]
173 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
197 197  
198 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
199 -
200 -(% style="text-align:center" %)
201 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
202 -
203 203  = **Rockwell PLC** =
204 204  
205 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
177 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
206 206  
207 207  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
208 208  
... ... @@ -241,7 +241,7 @@
241 241  
242 242  
243 243  
244 -== **CompactLogix** ==
216 +== **CompactLogix Protocol** ==
245 245  
246 246  (((
247 247  (((
... ... @@ -450,40 +450,40 @@
450 450  
451 451  
452 452  = **Siemens PLC** =
425 +
426 +== **S7-200 Smart Ethernet Protocol** ==
427 +
428 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
453 453  )))
454 454  )))
455 455  
456 -== **Siemens S7-1200** ==
432 +== **S7-1200 Ethernet Protocol** ==
457 457  
458 458  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
459 459  
460 -== **Communication with S7-200 Smart** ==
436 += **Mitsubishi PLC** =
461 461  
462 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
438 +== **Mitsubishi FX Series Protocol** ==
463 463  
440 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
441 +
464 464  = **Delta PLC** =
465 465  
466 -== **Delta DVP Ethernet** ==
444 +== **DVP Ethernet Protocol** ==
467 467  
468 468  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
469 469  
470 -== **Delta DVP Serial Protocol** ==
448 +== **DVP Serial Protocol** ==
471 471  
472 472  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
473 473  
474 -= **Mitsubishi PLC** =
475 -
476 -== **Communicate with Mitsubishi FX Series** ==
477 -
478 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
479 -
480 480  = **Omron PLC** =
481 481  
482 -== **Omron CP1 Series** ==
454 +== **CP1 Series Protocol** ==
483 483  
484 484  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
485 485  
486 -== **Omron CJ2M** ==
458 +== **CJ2M Series Protocol** ==
487 487  
488 488  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
489 489  
... ... @@ -534,7 +534,7 @@
534 534  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
535 535  |0F (Write multiple bits)
536 536  
537 -== **Communicate with VB inverter** ==
509 +== **communicate with VB inverter** ==
538 538  
539 539  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
540 540  
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content
image-20220824142130-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.2 KB
Content
image-20220824142546-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220824142643-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
image-20220824142722-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
image-20220824143613-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content