Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 56.1
edited by Ben
on 2022/08/24 11:37
Change comment: There is no comment for this version
To version 69.1
edited by Ben
on 2022/08/24 12:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,6 @@
1 1  = (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **LX3V 串行通信** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -35,24 +35,16 @@
35 35  
36 36  **Cable Wiring**
37 37  
38 -* **RS485**
39 -
40 - [[image:image-20220822172124-1.png]]
41 -
42 42  * **RS422**
43 43  
44 - [[image:image-20220822172228-2.png]]
40 + [[image:image-20220824120614-5.png]]
45 45  
42 +* **RS485**
46 46  
47 -**✎Note:**
44 + [[image:image-20220824120524-3.png]]
48 48  
49 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
50 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
46 +== **LX5V Serial Protocol** ==
51 51  
52 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
53 -
54 -== **LX5V serial communication** ==
55 -
56 56  This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
57 57  
58 58  **Software configuration of PLC**
... ... @@ -127,7 +127,7 @@
127 127  
128 128  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
129 129  
130 -== **LX5V-N Ethernet communication** ==
122 +== **LX5V-N Ethernet protocol** ==
131 131  
132 132   This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
133 133  
... ... @@ -202,7 +202,7 @@
202 202  
203 203  = **Rockwell PLC** =
204 204  
205 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
197 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
206 206  
207 207  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
208 208  
... ... @@ -241,7 +241,7 @@
241 241  
242 242  
243 243  
244 -== **CompactLogix** ==
236 +== **CompactLogix Protocol** ==
245 245  
246 246  (((
247 247  (((
... ... @@ -450,40 +450,40 @@
450 450  
451 451  
452 452  = **Siemens PLC** =
445 +
446 +== **S7-200 Smart Ethernet Protocol** ==
447 +
448 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
453 453  )))
454 454  )))
455 455  
456 -== **Siemens S7-1200** ==
452 +== **S7-1200 Ethernet Protocol** ==
457 457  
458 458  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
459 459  
460 -== **Communication with S7-200 Smart** ==
461 -
462 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
463 -
464 464  = **Mitsubishi PLC** =
465 465  
466 -== **Communicate with Mitsubishi FX Series** ==
458 +== **Mitsubishi FX Series Protocol** ==
467 467  
468 468  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
469 469  
470 470  = **Delta PLC** =
471 471  
472 -== **Delta DVP Ethernet** ==
464 +== **DVP Ethernet Protocol** ==
473 473  
474 474  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
475 475  
476 -== **Delta DVP Serial Protocol** ==
468 +== **DVP Serial Protocol** ==
477 477  
478 478  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
479 479  
480 480  = **Omron PLC** =
481 481  
482 -== **Omron CP1 Series** ==
474 +== **CP1 Series Protocol** ==
483 483  
484 484  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
485 485  
486 -== **Omron CJ2M** ==
478 +== **CJ2M Series Protocol** ==
487 487  
488 488  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
489 489  
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content