Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,54 @@ 1 -= (% style="color:inherit; font-family:inherit" %)**WECONPLC**(%%)=1 += **Modbus RTU** = 2 2 3 -== ** Communication with LX3V** ==3 +=== **V-BOX as master** === 4 4 5 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 6 + 7 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 8 + 9 +(% style="text-align:center" %) 10 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 11 + 12 +=== **V-BOX as slave** === 13 + 14 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 15 + 16 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 17 + 18 +(% style="text-align:center" %) 19 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 20 + 21 +**Address List** 22 + 23 +(% class="table-bordered" %) 24 +|**Type**|**Register**|**Function code & Description** 25 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 26 +|06 (write single register: write a binary value to a holding register) 27 +|10 (write values to multiple addresses ) 28 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 29 +|06 (write single register: write a binary value to a holding register) 30 +|10 (write values to multiple addresses ) 31 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 32 +|06 (write single register: write a binary value to a holding register) 33 +|10 (write values to multiple addresses ) 34 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 35 +|10 (write values to multiple addresses ) 36 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 37 +|05 (Force a single coil to force the on/off state of a logic coil) 38 +|0F (Write multiple bits, ie write continuously) 39 +|(% rowspan="3" %)1|02 (Read the input state) 40 +|05 (Force a single coil to force the on/off state of a logic coil) 41 +|0F (Write multiple bits) 42 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 43 +|05 (Force a single coil to force the on/off state of a logic coil) 44 +|0F (Write multiple bits) 45 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 46 +|0F (Write multiple bits) 47 + 48 += **WECON PLC** = 49 + 50 +== **LX3V 串行通信** == 51 + 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 7 **HMI Settings** ... ... @@ -461,12 +461,6 @@ 461 461 462 462 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 463 463 464 -= **Mitsubishi PLC** = 465 - 466 -== **Communicate with Mitsubishi FX Series** == 467 - 468 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 469 - 470 470 = **Delta PLC** = 471 471 472 472 == **Delta DVP Ethernet** == ... ... @@ -477,6 +477,16 @@ 477 477 478 478 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 479 479 521 += **Mitsubishi PLC** = 522 + 523 +== **Communicate with Mitsubishi FX Series** == 524 + 525 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 526 + 527 +== **Communicate with VB inverter** == 528 + 529 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 530 + 480 480 = **Omron PLC** = 481 481 482 482 == **Omron CP1 Series** == ... ... @@ -487,59 +487,8 @@ 487 487 488 488 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 489 489 490 -= ** ModbusRTU** =541 += **2 User define protocol** = 491 491 492 -== **V-BOX as master** == 493 - 494 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 495 - 496 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 497 - 498 -(% style="text-align:center" %) 499 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 500 - 501 -== **V-BOX as slave** == 502 - 503 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 504 - 505 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 506 - 507 -(% style="text-align:center" %) 508 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 509 - 510 -**Address List** 511 - 512 -(% class="table-bordered" %) 513 -|**Type**|**Register**|**Function code & Description** 514 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 515 -|06 (write single register: write a binary value to a holding register) 516 -|10 (write values to multiple addresses ) 517 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 518 -|06 (write single register: write a binary value to a holding register) 519 -|10 (write values to multiple addresses ) 520 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 521 -|06 (write single register: write a binary value to a holding register) 522 -|10 (write values to multiple addresses ) 523 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 524 -|10 (write values to multiple addresses ) 525 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 526 -|05 (Force a single coil to force the on/off state of a logic coil) 527 -|0F (Write multiple bits, ie write continuously) 528 -|(% rowspan="3" %)1|02 (Read the input state) 529 -|05 (Force a single coil to force the on/off state of a logic coil) 530 -|0F (Write multiple bits) 531 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 532 -|05 (Force a single coil to force the on/off state of a logic coil) 533 -|0F (Write multiple bits) 534 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 535 -|0F (Write multiple bits) 536 - 537 -== **communicate with VB inverter** == 538 - 539 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 540 - 541 -= **User define protocol** = 542 - 543 543 More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 544 544 545 545 == **Read the temperature sensor.** ==