... ... @@ -1,10 +1,10 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += Create communication with WECON PLC =
2 2  
3 -== **LX3V Serial Port** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**HMI Settings**
7 +**1)V-BOX setting**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,8 +15,9 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**Address List**
18 +**2)Address List**
19 19  
20 +
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 22  |Y|Y|Y o|0~~303237|
... ... @@ -33,33 +33,29 @@
33 33  |S|S|S d|0~~99999|
34 34  |SD|SD|SD d|8000~~9999|
35 35  
36 -**Cable Wiring**
37 +**3)Configure the communication protocol**
37 37  
38 -* **RS485**
39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]]
39 39  
40 - [[image:image-20220822172124-1.png]]
41 +**4)Cable Wiring**
41 41  
42 42  * **RS422**
43 43  
44 - [[image:image-20220822172228-2.png]]
45 + [[image:image-20220824120614-5.png]]
45 45  
47 +* **RS485**
46 46  
47 -**✎Note:**
49 + [[image:image-20220824120524-3.png]]
48 48  
49 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
50 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
51 +== **LX5V Serial Protocol** ==
51 51  
52 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
53 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
53 53  
54 -== **LX5V Serial Port** ==
55 -
56 -This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
57 -
58 58  **Software configuration of PLC**
59 59  
60 60  **1)PLC programming software**
61 61  
62 -[[image:image-20220822172553-1.png]]
59 +[[image:image-20220824142722-1.png]]
63 63  
64 64  **2)New PLC project**
65 65  
... ... @@ -97,7 +97,6 @@
97 97  
98 98  [[image:image-20220824104909-2.png]]
99 99  
100 -
101 101  **3)Set communication port parameters**
102 102  
103 103  Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
... ... @@ -110,38 +110,33 @@
110 110  
111 111  Parity:No verification
112 112  
113 -[[image:image-20220811104012-1.png]]
109 +[[image:image-20220824142130-1.png]]
114 114  
115 -
116 116  **hardware connection**
117 117  
118 118  **1)Hardware wiring diagram**
119 119  
120 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
115 +[[image:image-20220824142546-2.png]]
121 121  
117 +[[image:image-20220824142643-3.png]]
122 122  
119 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
123 123  
124 -[[image:image-20220811103005-4.png]]
121 +== **LX5V-N Ethernet protocol** ==
125 125  
126 -[[image:image-20220811103227-7.png]]
123 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
127 127  
128 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
129 -
130 -== **LX5V-N Ethernet** ==
131 -
132 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
133 -
134 134  **Software configuration of PLC**
135 135  
136 136  **1)PLC programming software**
137 137  
138 -[[image:image-20220810164710-1.png]]
129 +[[image:image-20220824142722-1.png]]
139 139  
140 140  **2)New PLC project**
141 141  
142 142  Click New Project and select the PLC model.
143 143  
144 -[[image:image-20220811115454-1.png]]
135 +[[image:image-20220824143613-1.png]]
145 145  
146 146  **3)Set Ethernet port parameters**
147 147  
... ... @@ -153,63 +153,144 @@
153 153  
154 154  subnet mask:255.255.255.0
155 155  
156 -[[image:image-20220811140530-2.png]]
147 +[[image:image-20220824143744-2.png]]
157 157  
158 158  **4)Registers list**
159 159  
160 -[[image:image-20220811102219-3.png]]
151 +[[image:image-20220822172730-4.png]]
161 161  
162 -**HMI software configuration**
153 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
163 163  
164 -**1)HMI programming software**
155 +**1)V-BOX programming software**
165 165  
166 - [[image:image-20220810171237-4.png]]
157 + [[image:image-20220824104124-1.png]]
167 167  
168 -**2)New HMI project**
159 +**2)V-NET add device**
169 169  
170 -Click New Project and select the HMI model.
161 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
171 171  
172 -[[image:image-20220810172010-5.png]]
163 +[[image:image-20220824104909-2.png]]
173 173  
174 -**3)Set communication port parameters**
165 +**3)Set communication Protocol**
175 175  
176 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
167 +Click Communication to configure the LX5V plc protocol and IP address.
177 177  
178 -HMI IP address:192.168.39.201
169 +[[image:image-20220824144619-1.png]]
179 179  
180 -default gateway:192.168.39.1
171 +**hardware connection**
181 181  
182 -subnet mask:255.255.255.0
173 +**1)Hardware wiring diagram**
183 183  
184 -[[image:image-20220811170753-2.png]]
175 +[[image:image-20220824151127-2.png]]
185 185  
186 -Next, click Communication Settings to configure the IP of the HMI communication object.
177 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
187 187  
188 -[[image:image-20220811163047-1.png]]
179 += Create communication with **Rockwell PLC** =
189 189  
190 -**hardware connection**
181 +== **DF1 Advanced Protocol** ==
191 191  
192 -**1)Hardware wiring diagram**
183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
193 193  
194 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
185 +**1) V-Box Settings**
195 195  
196 -[[image:image-20220811170248-1.png]]
187 +|=Item|=Recommended |=Note
188 +|=Protocol|Allen Bradley DF1 Advanced|
189 +|=Connection|RS232|
190 +|=Baud rate|19200|
191 +|=Stop bits|1|
192 +|=Data bits|8|
193 +|=Parity|None|
194 +|=PLC Station No.|1|
195 +|=HMI Station No.|0|
197 197  
198 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
197 +**2) Address List**
199 199  
200 -(% style="text-align:center" %)
201 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 +|BN|BNddddd.dd|0.0~~99255.15|(((
205 +Bit data file B0~~B99
202 202  
203 -= **Rockwell PLC** =
207 +First two digits is for file number
204 204  
205 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 +)))
211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 +|NN|NNddddd.dd|0.0~~99255.15|(((
213 +Integer data file bit format N0~~N99
206 206  
215 +First two digits is for file number
216 +
217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 +)))
219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 +|TNS|TNSddddd|0~~99255|(((
223 +Timer Preset Value
224 +
225 +First two digits is for file number
226 +
227 +For example, TNS99255 represents file number T99, address 255.
228 +)))
229 +|TNP|TNPddddd|0~~99255|(((
230 +Timer Accumulator Value
231 +
232 +First two digits is for file number
233 +
234 +For example, TNP99255 represents file number T99, address 255.
235 +)))
236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 +|CNS|CNSddddd|0~~99255|(((
239 +Counter Preset Value
240 +
241 +First two digits is for file number
242 +
243 +For example, CNS99255 represents file number C99, address 255.
244 +)))
245 +|CNP|CNPddddd|0~~99255|(((
246 +Counter Accumulator Value
247 +
248 +First two digits is for file number
249 +
250 +For example, CNP99255 represents file number C99, address 255.
251 +)))
252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 +|NN|NNddd|0~~99255|(((
254 +Integer data file
255 +
256 +First two digits is for file number
257 +
258 +For example, NN99255 represents file number N99, address 255.
259 +)))
260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 +Only able to communicate with file number N7
262 +)))
263 +|FN|FNddddd|0~~99255|(((
264 +Floating point data file
265 +
266 +First two digits is for file number
267 +
268 +For example, FN99255 represents file number F99, address 255.
269 +)))
270 +|LN|LNddddd|0~~99255|Long
271 +
272 +**3) Cable Wiring**
273 +
274 +(% style="text-align:center" %)
275 +[[image:ABRS232.gif]]
276 +
277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
278 +
207 207  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
208 208  
209 -**HMI Settings**
281 +**1)V-BOX setting**
210 210  
211 211  |**Item**|**Settings**|**Note**
212 -|Protocol|Allen-Bradlley MicroLogix|
284 +|Protocol|Allen-Bradley DF1 Advanced|
213 213  |Connection|RS232|
214 214  |Baud rate|19200|
215 215  |Data bit|8|
... ... @@ -217,7 +217,7 @@
217 217  |Stop bit|1|
218 218  |PLC station No.|1|
219 219  
220 -**Address List**
292 +**2)Address List**
221 221  
222 222  |**Type**|**Device registers**|**Format**|**Range**|**Note**
223 223  |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
... ... @@ -235,14 +235,14 @@
235 235  |T|T nnhh|0~~ffff
236 236  |R|R nnhh|0~~ffff
237 237  
238 -**Cable Wiring**
310 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]]
239 239  
312 +**4)Configure the communication protocol**
313 +
240 240  [[image:image-20220824110724-1.png]]
241 241  
316 +== **Micro850_FreeTag Protocol** ==
242 242  
243 -
244 -== **CompactLogix** ==
245 -
246 246  (((
247 247  (((
248 248  This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
... ... @@ -380,7 +380,7 @@
380 380  
381 381  (((
382 382  (((
383 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
455 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
384 384  )))
385 385  
386 386  
... ... @@ -403,7 +403,7 @@
403 403  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
404 404  )))
405 405  
406 -[[image:image-20220714162814-10.png]]
478 +[[image:image-20220824164346-1.png]]
407 407  
408 408  
409 409  (((
... ... @@ -444,73 +444,1392 @@
444 444  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
445 445  
446 446  
447 -== **Allen-Bradley Ethernet DF1** ==
519 += **Allen-Bradley Ethernet DF1** =
448 448  
449 449  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
450 450  
451 451  
452 -= **Siemens PLC** =
524 += Create communication with **Siemens PLC** =
525 +
526 +== **S7-200 Smart Ethernet Protocol** ==
527 +
528 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
529 +
530 +
531 +== **S7-300 Ethernet Protocol** ==
532 +
533 +Supported Series: Siemens S7-300 series PLC
534 +
535 +**1)V-BOX setting**
536 +
537 +|**Items**|**Settings**|**Note**
538 +|Protocol|Simens S7-300 Ethernet|
539 +|Connection|Ethernet|
540 +|Port No.|102|
541 +|PLC station No.|2|Need to be same as the PLC setting
542 +
543 +**2)Address List**
544 +
545 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
546 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
547 +|Q|Q|Q ddddd.o|0.0~~99999.7|
548 +|M|M|M ddddd.o|0.0~~99999.7|
549 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
550 +nn: block number;
551 +
552 +dddd: address;
453 453  )))
554 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
555 +|Q|QW|QW ddddd|0~~99999|
556 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
557 +|MW|MW ddddd|0~~99999|(((
558 +MW0=MB(0~~1)
559 +
560 +MW2=MB(2~~3)
561 +
562 +Address value is a multiple of 2
454 454  )))
564 +|MD|MD ddddd|0~~99999|(((
565 +MD0=MB(0~~3)
455 455  
456 -== **Siemens S7-1200** ==
567 +MD4=MB(4~~7)
457 457  
569 +Address value is a multiple of 4
570 +)))
571 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
572 +nn: block number;
573 +
574 +dddd: address
575 +)))
576 +|DBxDBW|DBxDBW nndddd|0~~99999999
577 +|DBxDBD|DBxDBD nndddd|0~~99999999
578 +
579 +**3)Configure the communication protocol**
580 +
581 +[[image:image-20220824161345-1.png]]
582 +
583 +**4)Cable Wiring**
584 +
585 +[[image:image-20220824161450-2.png]]
586 +)))
587 +)))
588 +
589 +== **S7-1200 Ethernet Protocol** ==
590 +
458 458  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
459 459  
460 -== **Communication with S7-200 Smart** ==
593 +== **S7-XXX Ethernet Protocol** ==
461 461  
462 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
595 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
463 463  
464 -= **Mitsubishi PLC** =
597 +**1)V-BOX setting**
465 465  
466 -== **Communicate with Mitsubishi FX Series** ==
599 +|=**Items**|=**Settings**|=**Note**
600 +|Protocol|Siemens S7-XXX|
601 +|Connection|Ethernet|
602 +|Port No.|102|
603 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
604 +|HMI No.|Rack (Default as 0)|
467 467  
468 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
606 +Slot from TIA Portal is equal to Device No. of V-net
469 469  
470 -= **Delta PLC** =
608 +Rack from TIA Portal is equal to HMI No. of V-net
471 471  
472 -== **Delta DVP Ethernet** ==
610 +[[image:image-20220824162459-3.png]]
473 473  
474 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
612 +[[image:image-20220824163305-2.png]]
475 475  
476 -== **Delta DVP Serial Protocol** ==
614 +**2)Address List**
477 477  
478 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
616 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
617 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
618 +d:0~-~-9999
479 479  
480 -= **Omron PLC** =
620 +o:0-7
621 +)))|
622 +|Q|Q|Q d.o|(((
623 +d:0~-~-9999
481 481  
482 -== **Omron CP1 Series** ==
625 +o:0-7
626 +)))|
627 +|M|M|M d.o|(((
628 +d:0~-~-9999
483 483  
484 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
630 +o:0-7
631 +)))|
632 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
633 +nn:0-9999,
485 485  
486 -== **Omron CJ2M** ==
635 +dddd:0-9999,
487 487  
488 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
637 +o:0-7
638 +)))|(((
639 +nn:DB No.
489 489  
490 -= **Modbus RTU** =
641 +dddd:address value
491 491  
492 -== **V-BOX as master** ==
643 +o: digit address
644 +)))
645 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
646 +|M|MW|MW d|d:0-99999|(((
647 +MW0=MB(0~~1)
493 493  
494 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
649 +MW2=MB(2~~3)
495 495  
496 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD d|d:0-99999|(((
654 +MD0=MB(0~~3)
497 497  
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|I|IW|IW d|d:0-99999|
661 +|Q|QW|QW d|d:0-99999|
662 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
663 +nn:0-9999
664 +
665 +dddd:0-9999
666 +)))|(((
667 +nn:DB No.
668 +
669 +dddd:address value
670 +)))
671 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
672 +nn:0-9999
673 +
674 +dddd:0-9999
675 +)))|(((
676 +nn:DB No.
677 +
678 +dddd:address value
679 +
680 +Address value is a multiple of 2
681 +)))
682 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
683 +nn:0-9999
684 +
685 +dddd:0-9999
686 +)))|(((
687 +nn:DB No.
688 +
689 +dddd:address value
690 +
691 +Address value is a multiple of 4
692 +)))
693 +
694 +**3)Configure the communication protocol**
695 +
696 +[[image:image-20220824163448-3.png]]
697 +
698 +**✎Note:**
699 +
700 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
701 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
702 +
703 +**4)Cable Wiring**
704 +
705 +[[image:image-20220824162342-2.png]]
706 +
707 += Create communication with **Mitsubishi PLC** =
708 +
709 +== **FX1S,1N,2N Serial Protocol** ==
710 +
711 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
712 +
713 +**1)V-BOX Settings**
714 +
715 +|**Item**|**Settings**|**Note**
716 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
717 +|Connection|RS422/RS485/RS232|
718 +|Baud rate|9600~~115200|
719 +|Data bit|7/8|
720 +|Parity|EVEN/Odd/None|
721 +|Stop bit|1/2|
722 +|PLC station No.|1~~255|
723 +
724 +**2)Address List**
725 +
726 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
727 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
728 +|Y|Y|Y o|0~~303237|
729 +|M|M|M d|0~~99999|
730 +|T|T|T d|0~~99999|
731 +|C|C|C d|0~~99999|
732 +|S|S|S d|0~~99999|
733 +|SM|SM|SM d|8000~~9999|
734 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
735 +|Y|Y|Y o|0~~303237|
736 +|M|M|M d|0~~99999|
737 +|T|T|T d|0~~99999|
738 +|C|C|C d|0~~199|
739 +|D|D|D d|0~~7999|
740 +|S|S|S d|0~~99999|
741 +|SD|SD|SD d|8000~~9999|
742 +
743 +**3)Configure the communication protocol**
744 +
745 +[[image:image-20220825102844-3.png]]
746 +
747 +**4)Cable Wiring**
748 +
749 +* **RS422**
750 +
751 +[[image:image-20220825103350-4.png]]
752 +
753 +[[image:image-20220825100845-4.png]]
754 +
755 +
756 +== **FX3U,3G,3GA Serial Protocol** ==
757 +
758 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
759 +
760 +**1)V-BOX Settings**
761 +
762 +|**Item**|**Settings**|**Note**
763 +|Protocol|Mitsubishi FX3U/3G/3GA|
764 +|Connection|RS422/RS485/RS232|
765 +|Baud rate|9600~~115200|
766 +|Data bit|7/8|
767 +|Parity|EVEN/Odd/None|
768 +|Stop bit|1/2|
769 +|PLC station No.|1~~255|
770 +
771 +**2)Address List**
772 +
773 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
774 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
775 +|Y|Y|Y o|0~~303237|
776 +|M|M|M d|0~~99999|
777 +|T|T|T d|0~~99999|
778 +|C|C|C d|0~~99999|
779 +|S|S|S d|0~~99999|
780 +|SM|SM|SM d|8000~~9999|
781 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
782 +|Y|Y|Y o|0~~303237|
783 +|M|M|M d|0~~99999|
784 +|T|T|T d|0~~99999|
785 +|C|C|C d|0~~199|
786 +|D|D|D d|0~~7999|
787 +|S|S|S d|0~~99999|
788 +|SD|SD|SD d|8000~~9999|
789 +
790 +**3)Configure the communication protocol**
791 +
792 +[[image:image-20220825102649-2.png]]
793 +
794 +**4)Cable Wiring**
795 +
796 +* **RS422**
797 +
798 +[[image:image-20220825103421-5.png]]
799 +
800 +[[image:image-20220825100845-4.png]]
801 +
802 +
803 +== **FX3U Ethernet Protocol** ==
804 +
805 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
806 +
807 +**1)V-BOX Settings**
808 +
809 +|Items|Settings|Note
810 +|Protocol|Mitsubishi FX3U|
811 +|Connection|Ethernet|
812 +|Port No.|5009|Must be the same as the PLC setting
813 +|PLC station No.|0|
814 +
815 +**2)Address List**
816 +
817 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
818 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
819 +|Y|Y|Y OOO|0~~377|
820 +|M|M|M DDDD|0~~7679|
821 +|SM|SM|SM DDDD|8000~~8511|
822 +|S|S|S DDDD|0~~4095|
823 +|TS|TS|TS DDD|0~~511|
824 +|CS|CS|CS DDD|0~~255|
825 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
826 +|TN|TN|TN DDD|0~~511|
827 +|D|D|D DDDD|0~~7999|
828 +|SD|SD|SD DDDD|8000~~8511|
829 +|R|R|R DDDDD|0~~32767|
830 +
831 +**3)Ethernet Module Settings**
832 +
833 +FX3U-ENET-L module configuration
834 +Set up the FX3U-ENET-L Ethernet module settings as follows.
835 +Select the module location, which in this document is Module 0.
836 +
837 +[[image:image-20221116105850-1.png]]
838 +
839 +Select "Operational setting" to enter the following screen.
840 +
841 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
842 +
843 +[[image:image-20221116105947-1.png]]
844 +
845 +Select "Open setting" to enter the setting interface, the settings are as follows.
846 +
847 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
848 +
849 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
850 +
851 +[[image:image-20221116110802-1.png]]
852 +
853 +Click on "transter setup" - "PC side I/F setting", see the following figure.
854 +
855 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
856 +
857 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
858 +
859 +[[image:image-20221116110832-2.png||height="423" width="708"]]
860 +
861 +Read and write data from the Ethernet module
862 +
863 +[[image:image-20221116110907-3.png]]
864 +
865 +Set "Transter setup" to COM communication, and read or write operation as shown below
866 +
867 +[[image:image-20221116110917-4.png]]
868 +
869 +**4)PLC Settings (GX Works 2)**
870 +
871 +Create a blank FX5U project
872 +
873 +Find Current Connection in the navigation
874 +
875 +[[image:image-20221116111427-1.png||height="421" width="705"]]
876 +
877 +Select Connection Channel List
878 +
879 +Select Ethernet board communication
880 +
881 +[[image:image-20221116111451-2.png||height="421" width="705"]]
882 +
883 +Select Ethernet Module
884 +Set the IP address of the PLC
885 +
886 +[[image:image-20221116111509-3.png||height="666" width="699"]]
887 +
888 +Read or write PLC data, in this document is read
889 +
890 +[[image:image-20221116111651-4.png||height="416" width="697"]]
891 +
892 +[[image:image-20221116111727-5.png||height="416" width="697"]]
893 +
894 +**4)Configure the communication protocol**
895 +
896 +[[image:image-20221119101946-2.png||height="395" width="695"]]
897 +
898 +== **FX5U Serial Protocol** ==
899 +
900 +Mitsubishi FX5U series PLC
901 +
902 +**1)V-BOX Settings**
903 +
904 +|**Item**|**Settings**|**Note**
905 +|Protocol|Mitsubishi FX5U|
906 +|Connection|RS422/RS485|
907 +|Baud rate|9600|
908 +|Data bit|7|
909 +|Parity|Odd|
910 +|Stop bit|1|
911 +|PLC station No.|1~~255|Need to be the same as PLC settings
912 +
913 +**2)Address List**
914 +
915 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
916 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
917 +|Y|Y|Y o|0~~303237|
918 +|M|M|M d|0~~99999|
919 +|B|B|B h|0~~7FFF|
920 +|F|F|F d|0~~32767|
921 +|SB|SB|SB h|0~~7FFF|
922 +|TS|TS|TS d|0~~1023|
923 +|TC|TC|TC d|0~~1023|
924 +|STS|STS|STS d|0~~1023|
925 +|STC|STC|STS d|0~~1023|
926 +|CS|CS|CS d|0~~1023|
927 +|CC|CC|CC d|0~~1023|
928 +|SM|SM|SM d|0~~9999|
929 +|L|L|L d|0~~32767|
930 +|S|S|S d|0~~4095|
931 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
932 +|TN|TN|TN d|0~~1023|
933 +|STN|STN|STN d|0~~1023|
934 +|CN|CN|CN d|0~~1023|
935 +|R|R|R d|0~~32767|
936 +|SW|SW|SW h|0~~7FFF|
937 +|Z|Z|Z d|0~~23|
938 +|D|D|D d|0~~7999|
939 +|SD|SD|SD d|0~~11999|
940 +
941 +**3)PLC Settings (GX Works 3)**
942 +
943 +Create a blank FX5U project
944 +
945 +Find the 485 serial port module in the system navigation bar and double click to enter the settings.
946 +
947 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
948 +
949 +Select protocol in the setting item, and set parameters.
950 +
951 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
952 +
953 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
954 +
955 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
956 +
957 +Click the [Apply] button to finish the setting.
958 +
959 +Click download and select the items as below, then click [execute] to download the configuration to PLC.
960 +
961 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
962 +
963 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
964 +
965 +Done.
966 +
967 +**4)Configure the communication protocol**
968 +
969 +[[image:image-20220825104904-1.png]]
970 +
971 +**5)Cable Wiring**
972 +
973 +
974 +* **RS422**
975 +
976 +[[image:image-20220825105105-2.png]]
977 +
978 +[[image:image-20220825105533-3.png]]
979 +
980 +== **FX5U Ethernet Protocol** ==
981 +
982 +Mitsubishi FX5U series PLC
983 +
984 +**1)V-BOX Settings**
985 +
986 +|**Items**|**Settings**|**Note**
987 +|Protocol|Mitsubishi FX5U|
988 +|Connection|Ethernet|
989 +|Port No.|5002|Must be the same as the PLC setting
990 +|PLC station No.|0|
991 +
992 +**2)Address List**
993 +
994 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
995 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
996 +|Y|Y|Y o|0~~303237|
997 +|M|M|M d|0~~99999|
998 +|B|B|B h|0~~7FFF|
999 +|F|F|F d|0~~32767|
1000 +|SB|SB|SB h|0~~7FFF|
1001 +|TS|TS|TS d|0~~1023|
1002 +|TC|TC|TC d|0~~1023|
1003 +|STS|STS|STS d|0~~1023|
1004 +|STC|STC|STS d|0~~1023|
1005 +|CS|CS|CS d|0~~1023|
1006 +|CC|CC|CC d|0~~1023|
1007 +|SM|SM|SM d|0~~9999|
1008 +|L|L|L d|0~~32767|
1009 +|S|S|S d|0~~4095|
1010 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
1011 +|TN|TN|TN d|0~~1023|
1012 +|STN|STN|STN d|0~~1023|
1013 +|CN|CN|CN d|0~~1023|
1014 +|R|R|R d|0~~32767|
1015 +|SW|SW|SW h|0~~7FFF|
1016 +|Z|Z|Z d|0~~23|
1017 +|D|D|D d|0~~7999|
1018 +|SD|SD|SD d|0~~11999|
1019 +
1020 +**3)PLC Settings (GX Works 3)**
1021 +
1022 +Find the [Ethernet port] in the navigation area.
1023 +
1024 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
1025 +
1026 +Select [Own Node Settings] in the [Setting Item List];
1027 +
1028 +Set [IP Address], [Subnet Mask], [Default Gateway];
1029 +
1030 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
1031 +
1032 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
1033 +
1034 +Select [SLMP Connection Module] and add into host station as below picture shows;
1035 +
1036 +Set Port number as 5002 (this is necessary settings);
1037 +
1038 +Click [Close with Reflecting the Setting] to save and close window;
1039 +
1040 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
1041 +
1042 +Click [Apply] to completed Etherenet settings;
1043 +
1044 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
1045 +
1046 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
1047 +
1048 +**4)Configure the communication protocol**
1049 +
1050 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
1051 +
1052 +**5)Cable Wiring**
1053 +
1054 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1055 +
1056 +== **L02 Serial Protocol** ==
1057 +
1058 +Mitsubishi L02 series CPU built-in serial port.
1059 +
1060 +**1)V-BOX Settings**
1061 +
1062 +|**Item**|**Settings**|**Note**
1063 +|Protocol|Mitsubishi L02|
1064 +|Connection|RS422|
1065 +|Baud rate|115200|
1066 +|Data bit|8|
1067 +|Parity|Odd|
1068 +|Stop bit|1|
1069 +|PLC station No.|1~~255|Need to be the same as PLC settings
1070 +
1071 +**2)Address List**
1072 +
1073 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1074 +|Bit|X|X|X h|0~~FFFF|
1075 +|Bit|Y|Y|Y h|0~~FFFF|
1076 +|Bit|M|M|M d|0~~9999|
1077 +|Bit|L|L|L d|0~~9999|
1078 +|Bit|F|F|F d|0~~9999|
1079 +|Bit|B|B|B h|0~~FFFF|
1080 +|Bit|V|V|V d|0~~2047|
1081 +|Bit|TC|TC|TC d|0~~9999|
1082 +|Bit|SS|SS|SS d|0~~9999|
1083 +|Bit|SC|SC|SC d|0~~9999|
1084 +|Bit|CS|CS|CS d|0~~9999|
1085 +|Bit|CC|CC|CC d|0~~9999|
1086 +|Bit|SB|SB|SB h|0~~FFFF|
1087 +|Bit|SM|SM|SM d|0~~2047|
1088 +|Bit|STS|STS|STS d|0~~1023|
1089 +|Bit|S|S|S d|0~~9999|
1090 +|Bit|DX|DX|DX h|0~~FFFF|
1091 +|Bit|DY|DY|DY h|0~~FFFF|
1092 +|Bit|TS|TS|TS d|0~~9999|
1093 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
1094 +|Word|W|W|W h|0~~FFFF|
1095 +|Word|TN|TN|TN d|0~~99999|
1096 +|Word|SN|SN|SN d|0~~99999|
1097 +|Word|CN|CN|CN d|0~~99999|
1098 +|Word|R|R|R d|0~~99999|
1099 +|Word|SW|SW|SW h|0~~FFFF|
1100 +|Word|Z|Z|Z d|0~~99999|
1101 +|Word|ZR|ZR|ZR h|0~~FFFF|
1102 +|Word|D|D|D d|0~~99999|
1103 +
1104 +**3)Communication Settings**
1105 +
1106 +[[image:image-20220825160648-3.png]]
1107 +
1108 +**4)Cable Wiring**
1109 +
1110 +* **RS422**
1111 +
1112 +[[image:image-20220825161612-8.png]]
1113 +
1114 +[[image:image-20220825160820-4.png]]
1115 +
1116 +== **L02 Ethernet Protocol** ==
1117 +
1118 +Mitsubishi L series CPU built-in Ethernet port.
1119 +
1120 +**1)V-BOX Settings**
1121 +
1122 +|**Items**|**Settings**|**Note**
1123 +|Protocol|MIT L02 CPU MELSEC|
1124 +|Connection|Ethernet|
1125 +|Port No.|1025|Must be the same as the PLC setting
1126 +|PLC station No.|0|Must be the same as the PLC setting
1127 +
1128 +**2)Address List**
1129 +
1130 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1131 +|Bit|X|X|X h|0~~FFFF|
1132 +|Bit|Y|Y|Y h|0~~FFFF|
1133 +|Bit|M|M|M d|0~~9999|
1134 +|Bit|L|L|L d|0~~9999|
1135 +|Bit|F|F|F d|0~~9999|
1136 +|Bit|B|B|B h|0~~FFFF|
1137 +|Bit|V|V|V d|0~~2047|
1138 +|Bit|TC|TC|TC d|0~~9999|
1139 +|Bit|SS|SS|SS d|0~~9999|
1140 +|Bit|SC|SC|SC d|0~~9999|
1141 +|Bit|CS|CS|CS d|0~~9999|
1142 +|Bit|CC|CC|CC d|0~~9999|
1143 +|Bit|SB|SB|SB h|0~~FFFF|
1144 +|Bit|SM|SM|SM d|0~~2047|
1145 +|Bit|STS|STS|STS d|0~~1023|
1146 +|Bit|S|S|S d|0~~9999|
1147 +|Bit|DX|DX|DX h|0~~FFFF|
1148 +|Bit|DY|DY|DY h|0~~FFFF|
1149 +|Bit|TS|TS|TS d|0~~9999|
1150 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
1151 +|Word|W|W|W h|0~~FFFF|
1152 +|Word|TN|TN|TN d|0~~99999|
1153 +|Word|SN|SN|SN d|0~~99999|
1154 +|Word|CN|CN|CN d|0~~99999|
1155 +|Word|R|R|R d|0~~99999|
1156 +|Word|SW|SW|SW h|0~~FFFF|
1157 +|Word|Z|Z|Z d|0~~99999|
1158 +|Word|ZR|ZR|ZR h|0~~FFFF|
1159 +|Word|D|D|D d|0~~99999|
1160 +
1161 +**3)PLC Settings (GX Works2 )**
1162 +
1163 +Create a project
1164 +
1165 +Set PLC IP, subnet mask and gateway;
1166 +
1167 +Select [Binary Code] as communication data code;
1168 +
1169 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
1170 +
1171 +Set PLC port number, for example 1025
1172 +
1173 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
1174 +
1175 +Save settings;
1176 +
1177 +Download project into PLC device;
1178 +
1179 +Restart PLC device;
1180 +
1181 +**4)Configure the communication protocol**
1182 +
1183 +[[image:image-20220825142659-1.png]]
1184 +
1185 +**5)Cable Wiring**
1186 +
1187 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1188 +
1189 +== **Q12H Serial Protocol** ==
1190 +
1191 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1192 +
1193 +[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1194 +
1195 +== **QJ71E71 Ethernet Protocol** ==
1196 +
1197 +Mitsubishi QJ71E71 Ethernet communication module;
1198 +
1199 +**1)V-BOX Settings**
1200 +
1201 +|**Items**|**Settings**|**Note**
1202 +|Protocol|MIT QJ71E71 MELSEC|
1203 +|Connection|Ethernet|
1204 +|Port No.|1025|Must be the same as the PLC setting
1205 +|PLC station No.|0|Must be the same as the PLC setting
1206 +
1207 +**2)Address List**
1208 +
1209 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1210 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
1211 +|Y|Y|Y h|0~~1FFF|
1212 +|M|M|M d|0~~99999|
1213 +|L|L|L d|0~~8191|
1214 +|F|F|F d|0~~2047|
1215 +|B|B|B h|0~~1FFF|
1216 +|V|V|V d|0~~2047|
1217 +|TS|TS|TS d|0~~2047|
1218 +|TC|TC|TC d|0~~2047|
1219 +|SS|SS|SS d|0~~2047|
1220 +|SC|SC|SC d|0~~2047|
1221 +|CS|CS|CS d|0~~1023|
1222 +|CC|CC|CC d|0~~1023|
1223 +|SB|SB|SB h|0~~7FF|
1224 +|S|S|S d|0~~8191|
1225 +|DX|DX|DX h|0~~1FFF|
1226 +|DY|DY|DY h|0~~1FFF|
1227 +|SM|SM|SM d|8000~~9999|
1228 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
1229 +|D|D|D d|0~~12287|
1230 +|W|W|W h|0~~1FFF|
1231 +|TN|TN|TN d|0~~2047|
1232 +|SN|SN|SN d|0~~2047|
1233 +|CN|CN|CN d|0~~1023|
1234 +|R|R|R d|0~~32767|
1235 +|SW|SW|SW h|0~~7FF|
1236 +|Z|Z|Z d|0~~15|
1237 +|ZR|ZR|ZR h|0~~FE7FF|
1238 +
1239 +**3)PLC Settings(GX Works2)**
1240 +
1241 +* Click [Ethernet/CC IE/MELSECNET];
1242 +* Please select [Ethernet] as network type;
1243 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1244 +* Select [Online] as Mode;
1245 +* [[image:image-20221119171343-2.png||height="341" width="587"]]
1246 +* Click [Operation setting] to set IP;
1247 +* Select [Binary Code] as [Communication Data Code];
1248 +* [[image:image-20221119171436-3.png||height="354" width="588"]]
1249 +* Click [Open setting]
1250 +* Set protocol: TCP;
1251 +* Set [unpassive] in [Open system];
1252 +* Set [receive] in [Fixed buffer];
1253 +* Set [procedure Exist] in [Fixed buffer communication];
1254 +* Disable [Pairing open];
1255 +* Set [No confirm] in [Existence confirmation];
1256 +* Host station port number: 5009;
1257 +* Save settings;
1258 +* [[image:image-20221119171611-4.png||height="354" width="588"]]
1259 +* Download project into PLC and restart it
1260 +
1261 +**4)Configure the communication protocol**
1262 +
1263 +[[image:image-20221119171832-5.png||height="354" width="625"]]
1264 +
1265 +
1266 +**5)Cable Wiring**
1267 +
1268 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1269 +
1270 += Create communication with **Delta PLC** =
1271 +
1272 +== **DVP Ethernet Protocol** ==
1273 +
1274 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1275 +
1276 +**1)V-BOX Settings**
1277 +
1278 +|=**Items**|=**Settings**|=**Note**
1279 +|Protocol|DELTA DVP MODBUS TCP|
1280 +|Connection|Ethernet|
1281 +|Port No.|502|
1282 +|Device No.|1|
1283 +|VBox Device No.|0|
1284 +
1285 +**2)Address List **
1286 +
1287 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1288 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1289 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1290 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1291 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1292 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1293 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1294 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1295 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1296 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1297 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1298 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1299 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1300 +
1301 +**3) PLC Setting:**
1302 +
1303 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1304 +
498 498  (% style="text-align:center" %)
1306 +[[image:DVPEthernetWPLSoft2.png]]
1307 +
1308 +2. Set up the communication type and PLC IP:
1309 +
1310 +(% style="text-align:center" %)
1311 +[[image:DVPEthernetSetup.png]]
1312 +
1313 +(% class="wikigeneratedid" %)
1314 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
1315 +
1316 +(% style="text-align:center" %)
1317 +[[image:DVPEthernetTransfer.png]]
1318 +
1319 +(% class="wikigeneratedid" %)
1320 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1321 +
1322 +(% style="text-align:center" %)
1323 +[[image:DVPEthernetPLCtoPC.png]]
1324 +
1325 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1326 +
1327 +(% style="text-align:center" %)
1328 +[[image:DVPEthernetAutoSearch.png]]
1329 +
1330 +**4) V-BOX Setting:**
1331 +
1332 +Set the same IP address according to the setting from WPL Soft:
1333 +
1334 +(% style="text-align:center" %)
1335 +[[image:DVPEthernetVNETPortocol.png]]
1336 +
1337 +== **DVP serial protocol** ==
1338 +
1339 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1340 +
1341 +**1)V-BOX Settings**
1342 +
1343 +|=**Items**|=**Settings**|=**Note**
1344 +|Protocol|DELTA DVP PROTOCOL|
1345 +|Connection|RS232|
1346 +|Baud Rate|9600|
1347 +|Stop Bit|1|
1348 +|Data Bit|7|
1349 +|Parity|EVEN|
1350 +|Device No.|1|
1351 +
1352 +(% class="wikigeneratedid" %)
1353 +**2)Address List**
1354 +
1355 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1356 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1357 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1358 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1359 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1360 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1361 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1362 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1363 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1364 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1365 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1366 +
1367 +(% class="wikigeneratedid" %)
1368 +**3)Wiring Diagram**
1369 +
1370 +(% style="text-align:center" %)
1371 +[[image:Delta DVP PROTOCOLSerial232.png]]
1372 +
1373 +== **AS Ethernet Protocol** ==
1374 +
1375 +**1)V-BOX Settings**
1376 +
1377 +|=**Items**|=**Settings**|=**Note**
1378 +|Protocol|DELTA AS300 MODBUS TCP|
1379 +|Connection|Ethernet|
1380 +|Port No.|502|
1381 +|Device No.|1|
1382 +|HMI No.|0|
1383 +
1384 +**2)Address List**
1385 +
1386 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1387 +|Bit|X|X|X d|0~~63|
1388 +|Bit|Y|Y|Y d|0~~63|
1389 +|Bit|D|D|D d|0~~29999|
1390 +|Bit|M|M|M d|0~~8191|
1391 +|Bit|SM|SM|SM d|0~~4095|
1392 +|Bit|S|S|S h|0~~2047|
1393 +|Bit|T|T|T d|0~~511|
1394 +|Bit|C|C|C d|0~~511|
1395 +|Bit|HC|HC|HC d|0~~255|
1396 +|Word|X|X|X h|0~~63|
1397 +|Word|Y|Y|Y d|0~~63|
1398 +|Word|SR|SR|SR d|0~~2047|
1399 +|Word|D|D|D d|0~~29999|
1400 +|Word|T|T|T d|0~~511|
1401 +|Word|C|C|C h|0~~511|
1402 +|Word|E|E|E d|0~~9|
1403 +
1404 +**3)Configure the communication protocol**
1405 +
1406 +[[image:image-20220831160010-4.png]]
1407 +
1408 +**4)Cable Wiring**
1409 +
1410 +Figure
1411 +
1412 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1413 +
1414 +Pin Definition Diagram
1415 +
1416 +[[image:image-20220831155157-3.png]]
1417 +
1418 += Create communication with **Omron PLC** =
1419 +
1420 +== **CP1 Series Protocol ** ==
1421 +
1422 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1423 +
1424 +== **CP2M Series Protocol** ==
1425 +
1426 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1427 +
1428 +
1429 +== **EC55 Series Protocol** ==
1430 +
1431 +Supported device: EC55 temperature instrument
1432 +
1433 +**1)V-BOX Settings**
1434 +
1435 +|**Items**|**Settings**|**Note**
1436 +|Protocol|Omron EC55|
1437 +|Connection|RS485 (9600, 2, 7, EVEN)|
1438 +|Port No.|None|
1439 +|PLC station No.|0|
1440 +
1441 +**2)Address List**
1442 +
1443 +|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1444 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1445 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1446 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1447 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1448 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1449 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1450 +|CP|-|0-6|Read controller intrinsic property
1451 +|CS|-|0-2|Read controller states
1452 +|CA|-|0-17|Action command
1453 +
1454 +**3)Device Settings**
1455 +
1456 +Omron E5CC PLC configuration
1457 +
1458 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1459 +
1460 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1461 +
1462 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1463 +
1464 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1465 +
1466 +**✎Note:** The communication settings for HMI should be consistent with this setting.
1467 +
1468 +**4)Configure the communication protocol**
1469 +
1470 +[[image:image-20220831161041-1.png]]
1471 +
1472 +**5)Cable Wiring**
1473 +
1474 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1475 +
1476 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1477 +
1478 +**✎Note:**
1479 +
1480 +* COM3 only available in PI8000/PI9000 series.
1481 +* CA address could not support continuous writing function;
1482 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1483 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1484 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1485 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1486 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1487 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1488 +* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1489 +
1490 += Create communication with Xinje** PLC** =
1491 +
1492 +== **XC serial protocol** ==
1493 +
1494 +**1)V-BOX Settings**
1495 +
1496 +|**Item**|**Settings**|**Note**
1497 +|Protocol|XINJE XC MODBUS|
1498 +|Connection|RS232|
1499 +|Baud rate|19200|
1500 +|Data bit|8|
1501 +|Parity|EVEN|
1502 +|Stop bit|1|
1503 +|PLC station No.|1|
1504 +
1505 +**2)Address List**
1506 +
1507 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1508 +|Bit|M|M|M d|0~~8511|
1509 +|Bit|X|X|X o|0~~1747|
1510 +|Bit|Y|Y|Y o|0~~1747|
1511 +|Bit|S|S|S d|0~~1023|
1512 +|Bit|T|T|T d|0~~4095|
1513 +|Bit|C|C|C d|0~~634|
1514 +|Word|D|D|D d|0~~8511|
1515 +|Word|TD|TD|TD d|0~~618|
1516 +|Word|CD|CD|CD d|0~~634|
1517 +|Word|FD|FD|FD d|0~~8511|
1518 +
1519 +**3)Configure the communication protocol**
1520 +
1521 +
1522 +[[image:image-20220831163041-1.png]]
1523 +
1524 +**4)Cable Wiring**
1525 +
1526 +Figure
1527 +
1528 +[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]]
1529 +
1530 +Pin Definition Diagram
1531 +
1532 +[[image:image-20220831163441-4.png]]
1533 +
1534 +== **XD serial protocol** ==
1535 +
1536 +**1)V-BOX Settings**
1537 +
1538 +Supported Series: Xinjie XD/XE Series PLC
1539 +
1540 +|**Item**|**Settings**|**Note**
1541 +|Protocol|XINJE XD/XC MODBUS|
1542 +|Connection|RS232|
1543 +|Baud rate|19200|
1544 +|Data bit|8|
1545 +|Parity|EVEN|
1546 +|Stop bit|1|
1547 +|PLC station No.|1|
1548 +
1549 +**2)Address List**
1550 +
1551 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1552 +|Bit|M|M|M d|0~~74999|
1553 +|Bit|X1xx|X1xx|X1xx o|0~~1177|
1554 +|Bit|X2xx|X2xx|X2xx o|0~~277|
1555 +|Bit|X|X|X o|0~~77|
1556 +|Bit|Y1xx|Y1xx|Y1xx o|0~~1177|
1557 +|Bit|Y2xx|Y2xx|Y2xx o|0~~277|
1558 +|Bit|Y|Y|Y o|0~~4095|
1559 +|Bit|SM|SM|SM d|0~~4999|(((
1560 +
1561 +)))
1562 +|Bit|T|T|T d|0~~4999|
1563 +|Bit|C|C|C d|0~~4999|
1564 +|Bit|ET|ET|ET d|0~~31|
1565 +|Bit|SE|SE|SE d|0~~31|
1566 +|Bit|HM|HM|HM d|0~~11999|
1567 +|Bit|HSC|HSC|HSC d|0~~39|
1568 +|Bit|HS|HS|HS d|0~~999|
1569 +|Bit|HT|HT|HT d|0~~1999|
1570 +|Bit|HC|HC|HC d|0~~1999|
1571 +|Bit|S|S|S d|0~~7999|
1572 +|Word|D|D|D d|0~~69999|
1573 +|Word|ID|ID|ID d|0~~99|
1574 +|Word|ID1xx|ID1xx|ID1xx d|0~~999|
1575 +|Word|ID2xx|ID2xx|ID2xx d|0~~299|
1576 +|Word|QD|QD|QD d|0~~99|
1577 +|Word|QD1xx|QD1xx|QD1xx d|0~~999|
1578 +|Word|QD2xx|QD2xx|QD2xx d|0~~299|
1579 +|Word|SD|SD|SD d|0~~4999|
1580 +|Word|TD|TD|TD d|0~~575|
1581 +|Word|CD|CD|CD d|0~~575|
1582 +|Word|ETD|ETD|ETD d|0~~31|
1583 +|Word|HD|HD|HD d|0~~24999|
1584 +|Word|HSD|HSD|HSD d|0~~1023|
1585 +|Word|HTD|HTD|HTD d|0~~95|
1586 +|Word|HCD|HCD|HCD d|0~~95|
1587 +|Word|HSCD|HSCD|HSCD d|0~~31|
1588 +|Word|FD|FD|FD d|0~~8191|
1589 +|Word|SFD|SFD|SFD d|0~~5999|
1590 +|Word|FS|FS|FS d|0~~47|
1591 +
1592 +**3)Configure the communication protocol**
1593 +
1594 +[[image:image-20220831163923-7.png]]
1595 +
1596 +
1597 +
1598 +**4)Cable Wiring**
1599 +
1600 +Figure
1601 +
1602 +[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]]
1603 +
1604 +Pin Definition Diagram
1605 +
1606 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1607 +
1608 += Create communication with **Schneider PLC** =
1609 +
1610 +== **Schneider MODBUS RTU** ==
1611 +
1612 +**1)V-BOX Setting**
1613 +
1614 +|=**Parameters**|=**Recommended**|=**Notes**
1615 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1616 +|**Connection**|RS485|
1617 +|**Baud rate**|19200|
1618 +|**Data bit**|8|
1619 +|**Parity**|Even|
1620 +|**Stop bit**|1|
1621 +|**PLC station No.**|1|
1622 +
1623 +**2)Address List**
1624 +
1625 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1626 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1627 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1628 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1629 +|W|MW|DDDDDD|0 ~~ 999999|Output register
1630 +|DW|MD|DDDDDD|0 ~~ 999999|Output register
1631 +
1632 +**3)Configure the communication protocol**
1633 +
1634 +[[image:image-20220902104329-1.png]]
1635 +
1636 +**4)Cable Wiring**
1637 +
1638 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1639 +
1640 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1641 +
1642 += Create communication with Inovance** PLC** =
1643 +
1644 +== **H3U serial protocol** ==
1645 +
1646 +**1)V-BOX Settings**
1647 +
1648 +|**Item**|**Settings**|**Note**
1649 +|Protocol|INOVANCE H3U PLC|
1650 +|Connection|RS422|
1651 +|Baud rate|9600|
1652 +|Data bit|7|
1653 +|Parity|EVEN|
1654 +|Stop bit|1|
1655 +|PLC station No.|0|
1656 +
1657 +**2)Address List**
1658 +
1659 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1660 +|Bit|X|X|X o|0~~303237|
1661 +|Bit|Y|Y|Y o|0~~303237|
1662 +|Bit|M|M|M d|0~~99999|
1663 +|Bit|T|T|T d|0~~99999|
1664 +|Bit|C|C|C d|0~~99999|
1665 +|Bit|SM|SM|SM d|8000~~999|
1666 +|Bit|S|T|S d|0~~99999|
1667 +|Bit|Lamp|Lamp|Lamp d|0~~0|
1668 +|Word|X|X|X o|0~~303237|
1669 +|Word|Y|Y|Y o|0~~303237|
1670 +|Word|M|M|M d|0~~99999|
1671 +|Word|T|T|T d|0~~99999|
1672 +|Word|C|C|C d|0~~199|
1673 +|Word|D|D|D d|0~~7999|
1674 +|Word|S|S|S d|0~~99999|
1675 +|Word|SD|SD|SD d|8000~~9999|
1676 +|Word|R|R|R d|0~~32767|
1677 +
1678 +**3)Configure the communication protocol**
1679 +
1680 +[[image:image-20220831164626-1.png]]
1681 +
1682 +
1683 +
1684 +**4)Cable Wiring**
1685 +
1686 +Figure
1687 +
1688 +[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1689 +
1690 +Pin Definition Diagram
1691 +
1692 +[[image:image-20220831164731-4.png]]
1693 +
1694 += Create communication with Panasonic** PLC** =
1695 +
1696 +== **FP serial protocol** ==
1697 +
1698 +**1)V-BOX Settings**
1699 +
1700 +|**Item**|**Settings**|**Note**
1701 +|Protocol|Panasonic FP MFWTOCOL|
1702 +|Connection|RS232|
1703 +|Baud rate|9600|
1704 +|Data bit|8|
1705 +|Parity|ODD|
1706 +|Stop bit|1|
1707 +|PLC station No.|1|
1708 +
1709 +**2)Address List**
1710 +
1711 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1712 +|Bit|X|X|X d|0~~9999|
1713 +|Bit|Y|Y|Y d|0~~9999|
1714 +|Bit|R|R|R d|0~~9999|
1715 +|Bit|T|T|T d|0~~9999|
1716 +|Bit|C|C|C d|0~~9999|
1717 +|Bit|L|L|L d|0~~9999|
1718 +|Word|WX|WX|WX d|0~~9999|
1719 +|Word|WY|WY|WY d|0~~9999|
1720 +|Word|WR|WR|WR d|0~~9999|
1721 +|Word|WL|WL|WL d|0~~9999|
1722 +|Word|LD|LD|LD d|0~~9999|
1723 +|Word|DT|DT|DT d|0~~65535|
1724 +|Word|FL|FL|FL d|0~~9999|
1725 +|Word|EV|EV|EV d|0~~9999|
1726 +|Word|SV|SV|SV d|0~~9999|
1727 +
1728 +**3)Configure the communication protocol**
1729 +
1730 +[[image:image-20220831165238-4.png]]
1731 +
1732 +
1733 +
1734 +**4)Cable Wiring**
1735 +
1736 +Figure
1737 +
1738 +[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1739 +
1740 +Pin Definition Diagram
1741 +
1742 +[[image:image-20220831165008-1.png]]
1743 +
1744 += Create communication with LS** PLC** =
1745 +
1746 +== **XBC serial protocol** ==
1747 +
1748 +**1)V-BOX Settings**
1749 +
1750 +|**Item**|**Settings**|**Note**
1751 +|Protocol|LS XBC CNet|
1752 +|Connection|RS232|
1753 +|Baud rate|115200|
1754 +|Data bit|8|
1755 +|Parity|NONE|
1756 +|Stop bit|1|
1757 +|PLC station No.|1|
1758 +
1759 +**2)Address List**
1760 +
1761 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1762 +|Bit|P|P|P d|0~~2047|
1763 +|Bit|M|M|M d|0~~2047|
1764 +|Bit|L|L|L d|0~~11263|
1765 +|Bit|K|K|K d|0~~16183|
1766 +|Bit|F|F|F d|0~~2047|
1767 +|Bit|D|D|D d|0~~32767|
1768 +|Bit|R|R|R d|0~~32767|
1769 +|Bit|U|U|U d|0~~4095|
1770 +|Word|P|P|P d|0~~2047|
1771 +|Word|M|M|M d|0~~2047|
1772 +|Word|L|L|L d|0~~11263|
1773 +|Word|K|K|K d|0~~16183|
1774 +|Word|F|F|F d|0~~2047|
1775 +|Word|C|C|C d|0~~2047|
1776 +|Word|T|T|T d|0~~2047|
1777 +|Word|D|D|D d|0~~32767|
1778 +|Word|N|N|N d|0~~21503|
1779 +|Word|R|R|R d|0~~32767|
1780 +|Word|U|U|U d|0~~4095|
1781 +|Word|Z|Z|Z d|0~~127|
1782 +|Word|S|S|S d|0~~127|
1783 +
1784 +**3)Configure the communication protocol**
1785 +
1786 +[[image:image-20220831170147-1.png]]
1787 +
1788 +**4)Cable Wiring**
1789 +
1790 +Figure
1791 +
1792 +[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1793 +
1794 +Pin Definition Diagram
1795 +
1796 +[[image:image-20220831170215-2.png]]
1797 +
1798 +== **XGK FEnet Ethernet protocol** ==
1799 +
1800 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1801 +
1802 +**1)V-BOX Settings**
1803 +
1804 +|**Items**|**Settings**|**Note**
1805 +|Protocol|LG XGK FEnet(Ethernet)|
1806 +|Connection|Ethernet|
1807 +|Port No.|2004|
1808 +
1809 +**2)Address List**
1810 +
1811 +|**Type**|**Register**|**Range**|**Format**|**Note**
1812 +|(% rowspan="14" %)Word|P|0~~2047|P d|
1813 +|M|0~~2047|M d|
1814 +|K|0~~2047|K d|
1815 +|F|0~~2047|F d|
1816 +|T|0~~2047|T d|
1817 +|C|0~~2047|C d|
1818 +|Z|0~~127|Z d|
1819 +|S|0~~127|S d|
1820 +|L|0~~11263|L d|
1821 +|N|0~~21503|N d|
1822 +|D|0~~32767|D d|
1823 +|R|0~~32767|R d|
1824 +|ZR|0~~65535|ZR d|
1825 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1826 +
1827 +**✎Note:**
1828 +
1829 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
1830 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1831 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
1832 +
1833 +**3)Communication Settings**
1834 +
1835 +[[image:image-20220831171127-1.png]]
1836 +
1837 +**4)Cable Wiring**
1838 +
1839 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1840 +
1841 += Create communication with **Modbus ** =
1842 +
1843 +== **MODBUS RTU Slave (All function)** ==
1844 +
1845 +Select the protocol "Modbus RTU Slave (All Fuction)",
1846 +
1847 +Then set baud rate, port, stop bits, data bits, parity.
1848 +
1849 +(% style="text-align:center" %)
499 499  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
500 500  
501 -== **V-BOX as slave** ==
1852 +== **MODBUS RTU Master** ==
502 502  
503 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
1854 +Select the protocol "Modbus RTU Master",
504 504  
505 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1856 +Then set baud rate, port, stop bits, data bits, parity
506 506  
507 507  (% style="text-align:center" %)
508 508  [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
509 509  
510 -**Address List**
1861 +**address list**
511 511  
512 512  (% class="table-bordered" %)
513 -|**Type**|**Register**|**Function code & Description**
1864 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
1865 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1866 +|06 (write single register: write a binary value to a holding register)
1867 +|10 (write values to multiple addresses )
1868 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1869 +|06 (write single register: write a binary value to a holding register)
1870 +|10 (write values to multiple addresses )
1871 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1872 +|06 (write single register: write a binary value to a holding register)
1873 +|10 (write values to multiple addresses )
1874 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1875 +|10 (write values to multiple addresses )
1876 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1877 +|05 (Force a single coil to force the on/off state of a logic coil)
1878 +|0F (Write multiple bits, ie write continuously)
1879 +|(% rowspan="3" %)1|02 (Read the input state)
1880 +|05 (Force a single coil to force the on/off state of a logic coil)
1881 +|0F (Write multiple bits)
1882 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1883 +|05 (Force a single coil to force the on/off state of a logic coil)
1884 +|0F (Write multiple bits)
1885 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1886 +|0F (Write multiple bits)
1887 +
1888 +== **MODBUS TCP Slave (All function)** ==
1889 +
1890 +Supported series: MODBUS TCP controller
1891 +
1892 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1893 +
1894 +**1)V-BOX Setting**
1895 +
1896 +|**Items**|**Settings**|**Note**
1897 +|Protocol|MODBUS TCP Slave (All function)|
1898 +|Connection|Ethernet|
1899 +|Port No.|502|
1900 +|PLC station No.|1
1901 +
1902 +**2)Address List**
1903 +
1904 +|=**Type**|=**Data Type**|=**Function code & Description**
514 514  |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
515 515  |06 (write single register: write a binary value to a holding register)
516 516  |10 (write values to multiple addresses )
... ... @@ -534,6 +534,21 @@
534 534  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
535 535  |0F (Write multiple bits)
536 536  
1928 +**3)Communication Settings**
1929 +
1930 +Configure V-BOX Ethernet IP in Networking Settings
1931 +
1932 +[[image:image-20220902111833-3.png]]
1933 +
1934 +
1935 +Configure PLC Ethernet IP in Communication;
1936 +
1937 +[[image:image-20220902111121-1.png]]
1938 +
1939 +**4)Cable Wiring**
1940 +
1941 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1942 +
537 537  == **communicate with VB inverter** ==
538 538  
539 539  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
AB.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.7 KB
Content
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content
image-20220824142130-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.2 KB
Content
image-20220824142546-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220824142643-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
image-20220824142722-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
image-20220824143613-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content
image-20220824152217-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.6 KB
Content
image-20220824152928-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +137.8 KB
Content
image-20220824161345-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824161450-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162339-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162342-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162459-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
image-20220824163110-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.3 KB
Content
image-20220824163305-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.5 KB
Content
image-20220824163448-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.8 KB
Content
image-20220824164346-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.2 KB
Content
image-20220825100807-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100814-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100845-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +403.6 KB
Content
image-20220825102641-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220825102649-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220825102844-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.8 KB
Content
image-20220825103350-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +65.9 KB
Content
image-20220825103421-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.0 KB
Content
image-20220825104904-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.5 KB
Content
image-20220825105105-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +78.5 KB
Content
image-20220825105533-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.8 KB
Content
image-20220825112403-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
image-20220825142437-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.5 KB
Content
image-20220825142659-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content
image-20220825143728-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.7 KB
Content
image-20220825160227-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +148.8 KB
Content
image-20220825160341-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.7 KB
Content
image-20220825160648-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
image-20220825160820-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20220825160925-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825160929-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825161440-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.7 KB
Content
image-20220825161612-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
image-20220831155101-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +59.6 KB
Content
image-20220831160055-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.5 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.1 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +27.0 KB
Content
image-20220831163041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.6 KB
Content
image-20220831163406-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.4 KB
Content
image-20220831163422-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.9 KB
Content
image-20220831163441-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220831163548-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +37.1 KB
Content
image-20220831163553-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +37.1 KB
Content
image-20220831163923-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.3 KB
Content
image-20220831164626-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content