Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 62.1
edited by Ben
on 2022/08/24 11:52
Change comment: There is no comment for this version
To version 51.1
edited by Ben
on 2022/08/24 11:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,34 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += =
2 2  
3 -== **LX3V Serial Port** ==
3 +(% class="table-bordered" %)
4 +| | |
5 +|(% rowspan="11" %) |(% rowspan="3" %) |
6 +|
7 +|
8 +|(% rowspan="3" %) |
9 +|
10 +|
11 +|(% rowspan="3" %) |
12 +|
13 +|
14 +|(% rowspan="2" %) |
15 +|
16 +|(% rowspan="11" %) |(% rowspan="3" %) |
17 +|
18 +|
19 +|(% rowspan="3" %) |
20 +|
21 +|
22 +|(% rowspan="3" %) |
23 +|
24 +|
25 +|(% rowspan="2" %) |
26 +|
4 4  
28 += **WECON PLC** =
29 +
30 +== **LX3V 串行通信** ==
31 +
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 7  **HMI Settings**
... ... @@ -51,7 +51,7 @@
51 51  
52 52  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
53 53  
54 -== **LX5V Serial Port** ==
81 +== **LX5V serial communication** ==
55 55  
56 56  This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
57 57  
... ... @@ -127,7 +127,7 @@
127 127  
128 128  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
129 129  
130 -== **LX5V-N Ethernet** ==
157 +== **LX5V-N Ethernet communication** ==
131 131  
132 132   This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
133 133  
... ... @@ -450,27 +450,20 @@
450 450  
451 451  
452 452  = **Siemens PLC** =
453 -
454 -
455 -== **S7-200 Smart Ethernet** ==
456 -
457 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
458 458  )))
459 459  )))
460 460  
461 -== **Siemens S7-1200 Ethernet** ==
483 +== **Siemens S7-1200** ==
462 462  
463 463  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
464 464  
465 -= **Mitsubishi PLC** =
487 +== **Communication with S7-200 Smart** ==
466 466  
467 -== **Mitsubishi FX Series Port** ==
489 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
468 468  
469 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
470 -
471 471  = **Delta PLC** =
472 472  
473 -== **DVP Ethernet** ==
493 +== **Delta DVP Ethernet** ==
474 474  
475 475  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
476 476  
... ... @@ -478,19 +478,30 @@
478 478  
479 479  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
480 480  
501 += **Mitsubishi PLC** =
502 +
503 +== **Communicate with Mitsubishi FX Series** ==
504 +
505 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
506 +
507 +== **Communicate with VB inverter** ==
508 +
509 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
510 +
481 481  = **Omron PLC** =
482 482  
483 -== **CP1 Series Port** ==
513 +== **Omron CP1 Series** ==
484 484  
485 485  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
486 486  
487 -== **CJ2M Series Port** ==
517 +== **Omron CJ2M** ==
488 488  
489 489  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
490 490  
521 +
491 491  = **Modbus RTU** =
492 492  
493 -== **V-BOX as master** ==
524 +=== **V-BOX as master** ===
494 494  
495 495  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
496 496  
... ... @@ -499,7 +499,7 @@
499 499  (% style="text-align:center" %)
500 500  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
501 501  
502 -== **V-BOX as slave** ==
533 +=== **V-BOX as slave** ===
503 503  
504 504  Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
505 505  
... ... @@ -535,10 +535,6 @@
535 535  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
536 536  |0F (Write multiple bits)
537 537  
538 -== **communicate with VB inverter** ==
539 -
540 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
541 -
542 542  = **User define protocol** =
543 543  
544 544  More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]