Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 67.1
edited by Ben
on 2022/08/24 12:00
Change comment: There is no comment for this version
To version 76.1
edited by Ben
on 2022/08/24 15:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -37,8 +37,12 @@
37 37  
38 38  * **RS422**
39 39  
40 - [[image:image-20220822172228-2.png]]
40 + [[image:image-20220824120614-5.png]]
41 41  
42 +* **RS485**
43 +
44 + [[image:image-20220824120524-3.png]]
45 +
42 42  == **LX5V Serial Protocol** ==
43 43  
44 44  This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
... ... @@ -47,7 +47,7 @@
47 47  
48 48  **1)PLC programming software**
49 49  
50 -[[image:image-20220822172553-1.png]]
54 +[[image:image-20220824142722-1.png]]
51 51  
52 52  **2)New PLC project**
53 53  
... ... @@ -98,38 +98,33 @@
98 98  
99 99  Parity:No verification
100 100  
101 -[[image:image-20220811104012-1.png]]
105 +[[image:image-20220824142130-1.png]]
102 102  
103 -
104 104  **hardware connection**
105 105  
106 106  **1)Hardware wiring diagram**
107 107  
108 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
111 +[[image:image-20220824142546-2.png]]
109 109  
113 +[[image:image-20220824142643-3.png]]
110 110  
115 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
111 111  
112 -[[image:image-20220811103005-4.png]]
113 -
114 -[[image:image-20220811103227-7.png]]
115 -
116 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
117 -
118 118  == **LX5V-N Ethernet protocol** ==
119 119  
120 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
119 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
121 121  
122 122  **Software configuration of PLC**
123 123  
124 124  **1)PLC programming software**
125 125  
126 -[[image:image-20220810164710-1.png]]
125 +[[image:image-20220824142722-1.png]]
127 127  
128 128  **2)New PLC project**
129 129  
130 130  Click New Project and select the PLC model.
131 131  
132 -[[image:image-20220811115454-1.png]]
131 +[[image:image-20220824143613-1.png]]
133 133  
134 134  **3)Set Ethernet port parameters**
135 135  
... ... @@ -141,53 +141,42 @@
141 141  
142 142  subnet mask:255.255.255.0
143 143  
144 -[[image:image-20220811140530-2.png]]
143 +[[image:image-20220824143744-2.png]]
145 145  
145 +
146 146  **4)Registers list**
147 147  
148 -[[image:image-20220811102219-3.png]]
148 +[[image:image-20220822172730-4.png]]
149 149  
150 -**HMI software configuration**
150 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
151 151  
152 -**1)HMI programming software**
152 +**1)V-BOX programming software**
153 153  
154 - [[image:image-20220810171237-4.png]]
154 + [[image:image-20220824104124-1.png]]
155 155  
156 -**2)New HMI project**
156 +**2)V-NET add device**
157 157  
158 -Click New Project and select the HMI model.
158 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
159 159  
160 -[[image:image-20220810172010-5.png]]
160 +[[image:image-20220824104909-2.png]]
161 161  
162 162  **3)Set communication port parameters**
163 163  
164 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
165 165  
166 -HMI IP address:192.168.39.201
165 +Click Communication to configure the LX5V plc protocol and IP address.
167 167  
168 -default gateway:192.168.39.1
167 +[[image:image-20220824144619-1.png]]
169 169  
170 -subnet mask:255.255.255.0
171 -
172 -[[image:image-20220811170753-2.png]]
173 -
174 -Next, click Communication Settings to configure the IP of the HMI communication object.
175 -
176 -[[image:image-20220811163047-1.png]]
177 -
178 178  **hardware connection**
179 179  
180 180  **1)Hardware wiring diagram**
181 181  
182 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
173 +This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
183 183  
184 -[[image:image-20220811170248-1.png]]
175 +[[image:image-20220824151127-2.png]]
185 185  
186 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
177 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
187 187  
188 -(% style="text-align:center" %)
189 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
190 -
191 191  = **Rockwell PLC** =
192 192  
193 193  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content
image-20220824142130-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.2 KB
Content
image-20220824142546-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220824142643-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
image-20220824142722-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
image-20220824143613-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content