Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,6 @@ 1 1 = (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = 2 2 3 -== **LX3V Serial P rotocol** ==3 +== **LX3V Serial Port** == 4 4 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 ... ... @@ -35,16 +35,24 @@ 35 35 36 36 **Cable Wiring** 37 37 38 +* **RS485** 39 + 40 + [[image:image-20220822172124-1.png]] 41 + 38 38 * **RS422** 39 39 40 - [[image:image-20220824120614-5.png]]44 + [[image:image-20220822172228-2.png]] 41 41 42 -* **RS485** 43 43 44 - [[image:image-20220824120524-3.png]][[image:file:///C:\Users\29709\AppData\Local\Temp\ksohtml13336\wps2.jpg]][[image:file:///C:\Users\29709\AppData\Local\Temp\ksohtml13336\wps1.jpg]]47 +**✎Note:** 45 45 46 -== **LX5V Serial Protocol** == 49 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 50 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 47 47 52 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 53 + 54 +== **LX5V Serial Port** == 55 + 48 48 This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 49 49 50 50 **Software configuration of PLC** ... ... @@ -119,7 +119,7 @@ 119 119 120 120 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 121 121 122 -== **LX5V-N Ethernet protocol** ==130 +== **LX5V-N Ethernet** == 123 123 124 124 This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 125 125 ... ... @@ -194,7 +194,7 @@ 194 194 195 195 = **Rockwell PLC** = 196 196 197 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==205 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 198 198 199 199 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 200 200 ... ... @@ -233,7 +233,7 @@ 233 233 234 234 235 235 236 -== **CompactLogix Protocol** ==244 +== **CompactLogix** == 237 237 238 238 ((( 239 239 ((( ... ... @@ -442,40 +442,40 @@ 442 442 443 443 444 444 = **Siemens PLC** = 445 - 446 -== **S7-200 Smart Ethernet Protocol** == 447 - 448 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 449 449 ))) 450 450 ))) 451 451 452 -== **S7-1200 Ethernet Protocol** ==456 +== **Siemens S7-1200** == 453 453 454 454 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 455 455 460 +== **Communication with S7-200 Smart** == 461 + 462 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 463 + 456 456 = **Mitsubishi PLC** = 457 457 458 -== **Mitsubishi FX Series Protocol** ==466 +== **Communicate with Mitsubishi FX Series** == 459 459 460 460 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 461 461 462 462 = **Delta PLC** = 463 463 464 -== **DVP Ethernet Protocol** ==472 +== **Delta DVP Ethernet** == 465 465 466 466 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 467 467 468 -== **DVP Serial Protocol** == 476 +== **Delta DVP Serial Protocol** == 469 469 470 470 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 471 471 472 472 = **Omron PLC** = 473 473 474 -== **CP1 Series Protocol** ==482 +== **Omron CP1 Series** == 475 475 476 476 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 477 477 478 -== **CJ2M Series Protocol** ==486 +== **Omron CJ2M** == 479 479 480 480 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 481 481
- image-20220824120406-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.9 KB - Content
- image-20220824120507-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -10.3 KB - Content
- image-20220824120524-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content
- image-20220824120547-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -49.2 KB - Content
- image-20220824120614-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.9 KB - Content