Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 69.1
edited by Ben
on 2022/08/24 12:06
Change comment: There is no comment for this version
To version 50.1
edited by Ben
on 2022/08/24 11:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,34 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +(% class="table-bordered" %)
4 +| | |
5 +|(% rowspan="11" %) |(% rowspan="3" %) |
6 +|
7 +|
8 +|(% rowspan="3" %) |
9 +|
10 +|
11 +|(% rowspan="3" %) |
12 +|
13 +|
14 +|(% rowspan="2" %) |
15 +|
16 +|(% rowspan="11" %) |(% rowspan="3" %) |
17 +|
18 +|
19 +|(% rowspan="3" %) |
20 +|
21 +|
22 +|(% rowspan="3" %) |
23 +|
24 +|
25 +|(% rowspan="2" %) |
26 +|
4 4  
28 += **WECON PLC** =
29 +
30 +== **LX3V 串行通信** ==
31 +
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 7  **HMI Settings**
... ... @@ -35,16 +35,24 @@
35 35  
36 36  **Cable Wiring**
37 37  
65 +* **RS485**
66 +
67 + [[image:image-20220822172124-1.png]]
68 +
38 38  * **RS422**
39 39  
40 - [[image:image-20220824120614-5.png]]
71 + [[image:image-20220822172228-2.png]]
41 41  
42 -* **RS485**
43 43  
44 - [[image:image-20220824120524-3.png]]
74 +**✎Note:**
45 45  
46 -== **LX5V Serial Protocol** ==
76 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
77 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
47 47  
79 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
80 +
81 +== **LX5V serial communication** ==
82 +
48 48  This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
49 49  
50 50  **Software configuration of PLC**
... ... @@ -119,7 +119,7 @@
119 119  
120 120  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
121 121  
122 -== **LX5V-N Ethernet protocol** ==
157 +== **LX5V-N Ethernet communication** ==
123 123  
124 124   This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
125 125  
... ... @@ -194,7 +194,7 @@
194 194  
195 195  = **Rockwell PLC** =
196 196  
197 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
232 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
198 198  
199 199  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
200 200  
... ... @@ -233,7 +233,7 @@
233 233  
234 234  
235 235  
236 -== **CompactLogix Protocol** ==
271 +== **CompactLogix** ==
237 237  
238 238  (((
239 239  (((
... ... @@ -442,46 +442,51 @@
442 442  
443 443  
444 444  = **Siemens PLC** =
445 -
446 -== **S7-200 Smart Ethernet Protocol** ==
447 -
448 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
449 449  )))
450 450  )))
451 451  
452 -== **S7-1200 Ethernet Protocol** ==
483 +== **Siemens S7-1200** ==
453 453  
454 454  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
455 455  
456 -= **Mitsubishi PLC** =
487 +== **Communication with S7-200 Smart** ==
457 457  
458 -== **Mitsubishi FX Series Protocol** ==
489 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
459 459  
460 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
461 -
462 462  = **Delta PLC** =
463 463  
464 -== **DVP Ethernet Protocol** ==
493 +== **Delta DVP Ethernet** ==
465 465  
466 466  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
467 467  
468 -== **DVP Serial Protocol** ==
497 +== **Delta DVP Serial Protocol** ==
469 469  
470 470  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
471 471  
501 += **Mitsubishi PLC** =
502 +
503 +== **Communicate with Mitsubishi FX Series** ==
504 +
505 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
506 +
507 +== **Communicate with VB inverter** ==
508 +
509 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
510 +
472 472  = **Omron PLC** =
473 473  
474 -== **CP1 Series Protocol** ==
513 +== **Omron CP1 Series** ==
475 475  
476 476  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
477 477  
478 -== **CJ2M Series Protocol** ==
517 +== **Omron CJ2M** ==
479 479  
480 480  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
481 481  
521 +
482 482  = **Modbus RTU** =
483 483  
484 -== **V-BOX as master** ==
524 +=== **V-BOX as master** ===
485 485  
486 486  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
487 487  
... ... @@ -490,7 +490,7 @@
490 490  (% style="text-align:center" %)
491 491  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
492 492  
493 -== **V-BOX as slave** ==
533 +=== **V-BOX as slave** ===
494 494  
495 495  Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
496 496  
... ... @@ -526,12 +526,8 @@
526 526  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
527 527  |0F (Write multiple bits)
528 528  
529 -== **communicate with VB inverter** ==
569 += **2 User define protocol** =
530 530  
531 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
532 -
533 -= **User define protocol** =
534 -
535 535  More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
536 536  
537 537  == **Read the temperature sensor.** ==
image-20220824120406-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -30.9 KB
Content