Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,31 +108,30 @@ 108 108 109 109 **1)Hardware wiring diagram** 110 110 111 -This example introduces WeconHMIwith LX5V PLC to establish communication through serial port. The connection diagram is as follows:111 +This example introduces V-BOX with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 112 112 113 113 [[image:image-20220824142546-2.png]] 114 114 115 115 [[image:image-20220824142643-3.png]] 116 116 117 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 117 117 118 118 119 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 120 - 121 121 == **LX5V-N Ethernet protocol** == 122 122 123 - 122 +This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 124 124 125 125 **Software configuration of PLC** 126 126 127 127 **1)PLC programming software** 128 128 129 -[[image:image-2022081 0164710-1.png]]128 +[[image:image-20220824142722-1.png]] 130 130 131 131 **2)New PLC project** 132 132 133 133 Click New Project and select the PLC model. 134 134 135 -[[image:image-2022081 1115454-1.png]]134 +[[image:image-20220824143613-1.png]] 136 136 137 137 **3)Set Ethernet port parameters** 138 138 ... ... @@ -144,52 +144,42 @@ 144 144 145 145 subnet mask:255.255.255.0 146 146 147 -[[image:image-2022081 1140530-2.png]]146 +[[image:image-20220824143744-2.png]] 148 148 148 + 149 149 **4)Registers list** 150 150 151 -[[image:image-202208 11102219-3.png]]151 +[[image:image-20220822172730-4.png]] 152 152 153 -** HMIsoftware configuration**153 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** 154 154 155 -**1) HMIprogramming software**155 +**1)V-BOX programming software** 156 156 157 - [[image:image-202208101 71237-4.png]]157 + [[image:image-20220824104124-1.png]] 158 158 159 -**2)N ewHMIproject**159 +**2)V-NET add device** 160 160 161 - ClickNewProject andselect theHMImodel.161 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 162 162 163 -[[image:image-202208 10172010-5.png]]163 +[[image:image-20220824104909-2.png]] 164 164 165 165 **3)Set communication port parameters** 166 166 167 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 168 168 169 - HMIIP address:192.168.39.201168 +Click Communication to configure the LX5V plc protocol and IP address. 170 170 171 - defaultgateway:192.168.39.1170 +[[image:image-20220824144619-1.png]] 172 172 173 -subnet mask:255.255.255.0 174 - 175 -[[image:image-20220811170753-2.png]] 176 - 177 -Next, click Communication Settings to configure the IP of the HMI communication object. 178 - 179 -[[image:image-20220811163047-1.png]] 180 - 181 181 **hardware connection** 182 182 183 183 **1)Hardware wiring diagram** 184 184 185 -This example introduces WeconHMIwith LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:176 +This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 186 186 187 -[[image:image-202208111 70248-1.png]]178 +[[image:image-20220824151127-2.png]] 188 188 189 -The above are all the steps for establishing ethernet communication between WeconHMIwith LX5V PLC.180 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 190 190 191 -(% style="text-align:center" %) 192 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 193 193 194 194 = **Rockwell PLC** = 195 195
- image-20220824143613-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +206.2 KB - Content
- image-20220824143744-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824144619-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.2 KB - Content
- image-20220824151127-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.5 KB - Content