... ... @@ -4,7 +4,7 @@
4 4  
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**HMI Settings**
7 +**1)PLC Settings**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,7 +15,7 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**Address List**
18 +**2)PLC Address List**
19 19  
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
... ... @@ -33,8 +33,12 @@
33 33  |S|S|S d|0~~99999|
34 34  |SD|SD|SD d|8000~~9999|
35 35  
36 -**Cable Wiring**
36 +**3)Configure the communication protocol**
37 37  
38 +[[image:image-20220824152217-1.png]]
39 +
40 +**4)hardware connection**
41 +
38 38  * **RS422**
39 39  
40 40   [[image:image-20220824120614-5.png]]
... ... @@ -45,7 +45,7 @@
45 45  
46 46  == **LX5V Serial Protocol** ==
47 47  
48 -This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
49 49  
50 50  **Software configuration of PLC**
51 51  
... ... @@ -89,7 +89,6 @@
89 89  
90 90  [[image:image-20220824104909-2.png]]
91 91  
92 -
93 93  **3)Set communication port parameters**
94 94  
95 95  Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
... ... @@ -108,31 +108,27 @@
108 108  
109 109  **1)Hardware wiring diagram**
110 110  
111 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 -
113 113  [[image:image-20220824142546-2.png]]
114 114  
115 115  [[image:image-20220824142643-3.png]]
116 116  
118 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
117 117  
118 -
119 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
120 -
121 121  == **LX5V-N Ethernet protocol** ==
122 122  
123 - This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
122 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
125 125  **Software configuration of PLC**
126 126  
127 127  **1)PLC programming software**
128 128  
129 -[[image:image-20220810164710-1.png]]
128 +[[image:image-20220824142722-1.png]]
130 130  
131 131  **2)New PLC project**
132 132  
133 133  Click New Project and select the PLC model.
134 134  
135 -[[image:image-20220811115454-1.png]]
134 +[[image:image-20220824143613-1.png]]
136 136  
137 137  **3)Set Ethernet port parameters**
138 138  
... ... @@ -144,53 +144,38 @@
144 144  
145 145  subnet mask:255.255.255.0
146 146  
147 -[[image:image-20220811140530-2.png]]
146 +[[image:image-20220824143744-2.png]]
148 148  
149 149  **4)Registers list**
150 150  
151 -[[image:image-20220811102219-3.png]]
150 +[[image:image-20220822172730-4.png]]
152 152  
153 -**HMI software configuration**
152 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
154 154  
155 -**1)HMI programming software**
154 +**1)V-BOX programming software**
156 156  
157 - [[image:image-20220810171237-4.png]]
156 + [[image:image-20220824104124-1.png]]
158 158  
159 -**2)New HMI project**
158 +**2)V-NET add device**
160 160  
161 -Click New Project and select the HMI model.
160 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
162 162  
163 -[[image:image-20220810172010-5.png]]
162 +[[image:image-20220824104909-2.png]]
164 164  
165 -**3)Set communication port parameters**
164 +**3)Set communication Protocol**
166 166  
167 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
166 +Click Communication to configure the LX5V plc protocol and IP address.
168 168  
169 -HMI IP address:192.168.39.201
168 +[[image:image-20220824144619-1.png]]
170 170  
171 -default gateway:192.168.39.1
172 -
173 -subnet mask:255.255.255.0
174 -
175 -[[image:image-20220811170753-2.png]]
176 -
177 -Next, click Communication Settings to configure the IP of the HMI communication object.
178 -
179 -[[image:image-20220811163047-1.png]]
180 -
181 181  **hardware connection**
182 182  
183 183  **1)Hardware wiring diagram**
184 184  
185 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
174 +[[image:image-20220824151127-2.png]]
186 186  
187 -[[image:image-20220811170248-1.png]]
176 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
188 188  
189 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
190 -
191 -(% style="text-align:center" %)
192 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
193 -
194 194  = **Rockwell PLC** =
195 195  
196 196  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
image-20220824143613-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content
image-20220824152217-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.6 KB
Content