... ... @@ -108,18 +108,15 @@
108 108  
109 109  **1)Hardware wiring diagram**
110 110  
111 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 -
113 113  [[image:image-20220824142546-2.png]]
114 114  
115 115  [[image:image-20220824142643-3.png]]
116 116  
117 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
115 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
118 118  
119 -
120 120  == **LX5V-N Ethernet protocol** ==
121 121  
122 -This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
119 +This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
123 123  
124 124  **Software configuration of PLC**
125 125  
... ... @@ -131,7 +131,7 @@
131 131  
132 132  Click New Project and select the PLC model.
133 133  
134 -[[image:image-20220822172623-2.png]]
131 +[[image:image-20220824143613-1.png]]
135 135  
136 136  **3)Set Ethernet port parameters**
137 137  
... ... @@ -143,52 +143,42 @@
143 143  
144 144  subnet mask:255.255.255.0
145 145  
146 -[[image:image-20220811140530-2.png]]
143 +[[image:image-20220824143744-2.png]]
147 147  
145 +
148 148  **4)Registers list**
149 149  
150 -[[image:image-20220811102219-3.png]]
148 +[[image:image-20220822172730-4.png]]
151 151  
152 -**HMI software configuration**
150 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
153 153  
154 -**1)HMI programming software**
152 +**1)V-BOX programming software**
155 155  
156 - [[image:image-20220810171237-4.png]]
154 + [[image:image-20220824104124-1.png]]
157 157  
158 -**2)New HMI project**
156 +**2)V-NET add device**
159 159  
160 -Click New Project and select the HMI model.
158 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
161 161  
162 -[[image:image-20220810172010-5.png]]
160 +[[image:image-20220824104909-2.png]]
163 163  
164 164  **3)Set communication port parameters**
165 165  
166 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
167 167  
168 -HMI IP address:192.168.39.201
165 +Click Communication to configure the LX5V plc protocol and IP address.
169 169  
170 -default gateway:192.168.39.1
167 +[[image:image-20220824144619-1.png]]
171 171  
172 -subnet mask:255.255.255.0
173 -
174 -[[image:image-20220811170753-2.png]]
175 -
176 -Next, click Communication Settings to configure the IP of the HMI communication object.
177 -
178 -[[image:image-20220811163047-1.png]]
179 -
180 180  **hardware connection**
181 181  
182 182  **1)Hardware wiring diagram**
183 183  
184 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
173 +This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
185 185  
186 -[[image:image-20220811170248-1.png]]
175 +[[image:image-20220824151127-2.png]]
187 187  
188 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
177 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
189 189  
190 -(% style="text-align:center" %)
191 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
192 192  
193 193  = **Rockwell PLC** =
194 194  
image-20220824143613-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content