Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -** HMISettings**7 +**1)PLC Settings** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,7 +15,7 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**Address List** 18 +**2)PLC Address List** 19 19 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| ... ... @@ -33,8 +33,12 @@ 33 33 |S|S|S d|0~~99999| 34 34 |SD|SD|SD d|8000~~9999| 35 35 36 -**C ableWiring**36 +**3)Configure the communication protocol** 37 37 38 +[[image:image-20220824152217-1.png]] 39 + 40 +**4)hardware connection** 41 + 38 38 * **RS422** 39 39 40 40 [[image:image-20220824120614-5.png]] ... ... @@ -45,7 +45,7 @@ 45 45 46 46 == **LX5V Serial Protocol** == 47 47 48 -This example introduces the establishment of serial port communication between WeconV-BOX and LX5V. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 49 49 50 50 **Software configuration of PLC** 51 51 ... ... @@ -89,7 +89,6 @@ 89 89 90 90 [[image:image-20220824104909-2.png]] 91 91 92 - 93 93 **3)Set communication port parameters** 94 94 95 95 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -108,18 +108,15 @@ 108 108 109 109 **1)Hardware wiring diagram** 110 110 111 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 112 - 113 113 [[image:image-20220824142546-2.png]] 114 114 115 115 [[image:image-20220824142643-3.png]] 116 116 117 -The above are all the steps for establishing serial port communication between WeconHMIwith LX5V PLC.118 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 118 118 119 - 120 120 == **LX5V-N Ethernet protocol** == 121 121 122 -This example introduces the establishment of Ethernet communication between WeconHMIand LX5V. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.122 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 123 123 124 124 **Software configuration of PLC** 125 125 ... ... @@ -131,7 +131,7 @@ 131 131 132 132 Click New Project and select the PLC model. 133 133 134 -[[image:image-2022082 2172623-2.png]]134 +[[image:image-20220824143613-1.png]] 135 135 136 136 **3)Set Ethernet port parameters** 137 137 ... ... @@ -143,53 +143,38 @@ 143 143 144 144 subnet mask:255.255.255.0 145 145 146 -[[image:image-2022081 1140530-2.png]]146 +[[image:image-20220824143744-2.png]] 147 147 148 148 **4)Registers list** 149 149 150 -[[image:image-202208 11102219-3.png]]150 +[[image:image-20220822172730-4.png]] 151 151 152 -** HMIsoftware configuration**152 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** 153 153 154 -**1) HMIprogramming software**154 +**1)V-BOX programming software** 155 155 156 - [[image:image-202208101 71237-4.png]]156 + [[image:image-20220824104124-1.png]] 157 157 158 -**2)N ewHMIproject**158 +**2)V-NET add device** 159 159 160 - ClickNewProject andselect theHMImodel.160 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 161 161 162 -[[image:image-202208 10172010-5.png]]162 +[[image:image-20220824104909-2.png]] 163 163 164 -**3)Set communication portparameters**164 +**3)Set communication Protocol** 165 165 166 -Click the projectsetting buttononthe left to configure theIPaddressofthe HMI machine toensure that the HMI andPLCIPremain in a local area network.166 +Click Communication to configure the LX5V plc protocol and IP address. 167 167 168 - HMI IPaddress:192.168.39.201168 +[[image:image-20220824144619-1.png]] 169 169 170 -default gateway:192.168.39.1 171 - 172 -subnet mask:255.255.255.0 173 - 174 -[[image:image-20220811170753-2.png]] 175 - 176 -Next, click Communication Settings to configure the IP of the HMI communication object. 177 - 178 -[[image:image-20220811163047-1.png]] 179 - 180 180 **hardware connection** 181 181 182 182 **1)Hardware wiring diagram** 183 183 184 - This examplentroduces WeconHMI with LX5V-N PLC to establish communication throughethernet.The connection diagram is as follows:174 +[[image:image-20220824151127-2.png]] 185 185 186 - [[image:image-20220811170248-1.png]]176 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 187 187 188 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 189 - 190 -(% style="text-align:center" %) 191 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 192 - 193 193 = **Rockwell PLC** = 194 194 195 195 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == ... ... @@ -196,10 +196,10 @@ 196 196 197 197 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 198 198 199 -** HMISettings**184 +**1)PLC Settings** 200 200 201 201 |**Item**|**Settings**|**Note** 202 -|Protocol|Allen-Bradlley MicroLogix|187 +|Protocol|Allen-Bradlley DF1 Advanced| 203 203 |Connection|RS232| 204 204 |Baud rate|19200| 205 205 |Data bit|8| ... ... @@ -207,7 +207,7 @@ 207 207 |Stop bit|1| 208 208 |PLC station No.|1| 209 209 210 -**Address List** 195 +**2)Address List** 211 211 212 212 |**Type**|**Device registers**|**Format**|**Range**|**Note** 213 213 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -225,12 +225,12 @@ 225 225 |T|T nnhh|0~~ffff 226 226 |R|R nnhh|0~~ffff 227 227 228 -**C ableWiring**213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 229 229 215 +**4)Configure the communication protocol** 216 + 230 230 [[image:image-20220824110724-1.png]] 231 231 232 - 233 - 234 234 == **CompactLogix Protocol** == 235 235 236 236 ((( ... ... @@ -444,9 +444,66 @@ 444 444 == **S7-200 Smart Ethernet Protocol** == 445 445 446 446 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 + 433 + 434 +== ** S7-300 Ethernet Protocol** == 435 + 436 +Supported Series: Siemens S7-300 series PLC 437 + 438 +**1)PLC Setting** 439 + 440 +|**Items**|**Settings**|**Note** 441 +|Protocol|Simens S7-300 Ethernet| 442 +|Connection|Ethernet| 443 +|Port No.|102| 444 +|PLC station No.|2|Need to be same as the PLC setting 445 + 446 +**2)Address List** 447 + 448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 +|Q|Q|Q ddddd.o|0.0~~99999.7| 451 +|M|M|M ddddd.o|0.0~~99999.7| 452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 +nn: block number; 454 + 455 +dddd: address; 447 447 ))) 457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 +|Q|QW|QW ddddd|0~~99999| 459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 +|MW|MW ddddd|0~~99999|((( 461 +MW0=MB(0~~1) 462 + 463 +MW2=MB(2~~3) 464 + 465 +Address value is a multiple of 2 448 448 ))) 467 +|MD|MD ddddd|0~~99999|((( 468 +MD0=MB(0~~3) 449 449 470 +MD4=MB(4~~7) 471 + 472 +Address value is a multiple of 4 473 +))) 474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 +nn: block number; 476 + 477 +dddd: address 478 +))) 479 +|DBxDBW|DBxDBW nndddd|0~~99999999 480 +|DBxDBD|DBxDBD nndddd|0~~99999999 481 + 482 +**3)Configure the communication protocol** 483 + 484 +[[image:image-20220824161345-1.png]] 485 + 486 +**Cable Wiring** 487 + 488 +[[image:image-20220824161450-2.png]] 489 +))) 490 +))) 491 + 450 450 == **S7-1200 Ethernet Protocol** == 451 451 452 452 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
- image-20220824143613-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +206.2 KB - Content
- image-20220824143744-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824144619-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.2 KB - Content
- image-20220824151127-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.5 KB - Content
- image-20220824152217-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.6 KB - Content
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.8 KB - Content
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content