Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 74.1
edited by Ben
on 2022/08/24 15:12
Change comment: There is no comment for this version
To version 144.1
edited by Ben
on 2022/08/31 16:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,10 +1,10 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += Create communication with WECON PLC =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**HMI Settings**
7 +**1)V-BOX setting**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,8 +15,9 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**Address List**
18 +**2)Address List**
19 19  
20 +
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 22  |Y|Y|Y o|0~~303237|
... ... @@ -33,8 +33,12 @@
33 33  |S|S|S d|0~~99999|
34 34  |SD|SD|SD d|8000~~9999|
35 35  
36 -**Cable Wiring**
37 +**3)Configure the communication protocol**
37 37  
39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]]
40 +
41 +**4)Cable Wiring**
42 +
38 38  * **RS422**
39 39  
40 40   [[image:image-20220824120614-5.png]]
... ... @@ -45,7 +45,7 @@
45 45  
46 46  == **LX5V Serial Protocol** ==
47 47  
48 -This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
53 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
49 49  
50 50  **Software configuration of PLC**
51 51  
... ... @@ -89,7 +89,6 @@
89 89  
90 90  [[image:image-20220824104909-2.png]]
91 91  
92 -
93 93  **3)Set communication port parameters**
94 94  
95 95  Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
... ... @@ -108,8 +108,6 @@
108 108  
109 109  **1)Hardware wiring diagram**
110 110  
111 -This example introduces V-BOX with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 -
113 113  [[image:image-20220824142546-2.png]]
114 114  
115 115  [[image:image-20220824142643-3.png]]
... ... @@ -116,10 +116,9 @@
116 116  
117 117  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
118 118  
119 -
120 120  == **LX5V-N Ethernet protocol** ==
121 121  
122 -This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
123 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
123 123  
124 124  **Software configuration of PLC**
125 125  
... ... @@ -145,7 +145,6 @@
145 145  
146 146  [[image:image-20220824143744-2.png]]
147 147  
148 -
149 149  **4)Registers list**
150 150  
151 151  [[image:image-20220822172730-4.png]]
... ... @@ -162,9 +162,8 @@
162 162  
163 163  [[image:image-20220824104909-2.png]]
164 164  
165 -**3)Set communication port parameters**
165 +**3)Set communication Protocol**
166 166  
167 -
168 168  Click Communication to configure the LX5V plc protocol and IP address.
169 169  
170 170  [[image:image-20220824144619-1.png]]
... ... @@ -173,23 +173,20 @@
173 173  
174 174  **1)Hardware wiring diagram**
175 175  
176 -This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
177 -
178 178  [[image:image-20220824151127-2.png]]
179 179  
180 180  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
181 181  
179 += Create communication with **Rockwell PLC** =
182 182  
183 -= **Rockwell PLC** =
184 -
185 185  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
186 186  
187 187  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
188 188  
189 -**HMI Settings**
185 +**1)PLC Settings**
190 190  
191 191  |**Item**|**Settings**|**Note**
192 -|Protocol|Allen-Bradlley MicroLogix|
188 +|Protocol|Allen-Bradlley DF1 Advanced|
193 193  |Connection|RS232|
194 194  |Baud rate|19200|
195 195  |Data bit|8|
... ... @@ -197,7 +197,7 @@
197 197  |Stop bit|1|
198 198  |PLC station No.|1|
199 199  
200 -**Address List**
196 +**2)Address List**
201 201  
202 202  |**Type**|**Device registers**|**Format**|**Range**|**Note**
203 203  |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
... ... @@ -215,14 +215,14 @@
215 215  |T|T nnhh|0~~ffff
216 216  |R|R nnhh|0~~ffff
217 217  
218 -**Cable Wiring**
214 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]]
219 219  
216 +**4)Configure the communication protocol**
217 +
220 220  [[image:image-20220824110724-1.png]]
221 221  
220 +== **Micro850_FreeTag Protocol** ==
222 222  
223 -
224 -== **CompactLogix Protocol** ==
225 -
226 226  (((
227 227  (((
228 228  This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
... ... @@ -360,7 +360,7 @@
360 360  
361 361  (((
362 362  (((
363 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
359 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
364 364  )))
365 365  
366 366  
... ... @@ -383,7 +383,7 @@
383 383  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
384 384  )))
385 385  
386 -[[image:image-20220714162814-10.png]]
382 +[[image:image-20220824164346-1.png]]
387 387  
388 388  
389 389  (((
... ... @@ -429,69 +429,800 @@
429 429  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
430 430  
431 431  
432 -= **Siemens PLC** =
428 += Create communication with **Siemens PLC** =
433 433  
434 434  == **S7-200 Smart Ethernet Protocol** ==
435 435  
436 436  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
433 +
434 +
435 +== **S7-300 Ethernet Protocol** ==
436 +
437 +Supported Series: Siemens S7-300 series PLC
438 +
439 +**1)PLC Setting**
440 +
441 +|**Items**|**Settings**|**Note**
442 +|Protocol|Simens S7-300 Ethernet|
443 +|Connection|Ethernet|
444 +|Port No.|102|
445 +|PLC station No.|2|Need to be same as the PLC setting
446 +
447 +**2)Address List**
448 +
449 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
450 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
451 +|Q|Q|Q ddddd.o|0.0~~99999.7|
452 +|M|M|M ddddd.o|0.0~~99999.7|
453 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
454 +nn: block number;
455 +
456 +dddd: address;
437 437  )))
458 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
459 +|Q|QW|QW ddddd|0~~99999|
460 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
461 +|MW|MW ddddd|0~~99999|(((
462 +MW0=MB(0~~1)
463 +
464 +MW2=MB(2~~3)
465 +
466 +Address value is a multiple of 2
438 438  )))
468 +|MD|MD ddddd|0~~99999|(((
469 +MD0=MB(0~~3)
439 439  
471 +MD4=MB(4~~7)
472 +
473 +Address value is a multiple of 4
474 +)))
475 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
476 +nn: block number;
477 +
478 +dddd: address
479 +)))
480 +|DBxDBW|DBxDBW nndddd|0~~99999999
481 +|DBxDBD|DBxDBD nndddd|0~~99999999
482 +
483 +**3)Configure the communication protocol**
484 +
485 +[[image:image-20220824161345-1.png]]
486 +
487 +**4)Cable Wiring**
488 +
489 +[[image:image-20220824161450-2.png]]
490 +)))
491 +)))
492 +
440 440  == **S7-1200 Ethernet Protocol** ==
441 441  
442 442  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
443 443  
444 -= **Mitsubishi PLC** =
497 +== **S7-XXX Ethernet Protocol** ==
445 445  
446 -== **Mitsubishi FX Series Protocol** ==
499 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
447 447  
448 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
501 +**1)PLC Setting**
449 449  
450 -= **Delta PLC** =
503 +|=**Items**|=**Settings**|=**Note**
504 +|Protocol|Siemens S7-XXX|
505 +|Connection|Ethernet|
506 +|Port No.|102|
507 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
508 +|HMI No.|Rack (Default as 0)|
451 451  
510 +Slot from TIA Portal is equal to Device No. of V-net
511 +
512 +Rack from TIA Portal is equal to HMI No. of V-net
513 +
514 +[[image:image-20220824162459-3.png]]
515 +
516 +[[image:image-20220824163305-2.png]]
517 +
518 +**2)Address List**
519 +
520 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
521 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
522 +d:0~-~-9999
523 +
524 +o:0-7
525 +)))|
526 +|Q|Q|Q d.o|(((
527 +d:0~-~-9999
528 +
529 +o:0-7
530 +)))|
531 +|M|M|M d.o|(((
532 +d:0~-~-9999
533 +
534 +o:0-7
535 +)))|
536 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
537 +nn:0-9999,
538 +
539 +dddd:0-9999,
540 +
541 +o:0-7
542 +)))|(((
543 +nn:DB No.
544 +
545 +dddd:address value
546 +
547 +o: digit address
548 +)))
549 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
550 +|M|MW|MW d|d:0-99999|(((
551 +MW0=MB(0~~1)
552 +
553 +MW2=MB(2~~3)
554 +
555 +Address value is a multiple of 2
556 +)))
557 +|M|MD|MD d|d:0-99999|(((
558 +MD0=MB(0~~3)
559 +
560 +MD4=MB(4~~7)
561 +
562 +Address value is a multiple of 4
563 +)))
564 +|I|IW|IW d|d:0-99999|
565 +|Q|QW|QW d|d:0-99999|
566 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
567 +nn:0-9999
568 +
569 +dddd:0-9999
570 +)))|(((
571 +nn:DB No.
572 +
573 +dddd:address value
574 +)))
575 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
576 +nn:0-9999
577 +
578 +dddd:0-9999
579 +)))|(((
580 +nn:DB No.
581 +
582 +dddd:address value
583 +
584 +Address value is a multiple of 2
585 +)))
586 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
587 +nn:0-9999
588 +
589 +dddd:0-9999
590 +)))|(((
591 +nn:DB No.
592 +
593 +dddd:address value
594 +
595 +Address value is a multiple of 4
596 +)))
597 +
598 +**3)Configure the communication protocol**
599 +
600 +[[image:image-20220824163448-3.png]]
601 +
602 +**✎Note:**
603 +
604 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
605 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
606 +
607 +**4)Cable Wiring**
608 +
609 +[[image:image-20220824162342-2.png]]
610 +
611 += Create communication with **Mitsubishi PLC** =
612 +
613 +== **FX1S,1N,2N Serial Protocol** ==
614 +
615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
616 +
617 +**1)V-BOX Settings**
618 +
619 +|**Item**|**Settings**|**Note**
620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
621 +|Connection|RS422/RS485/RS232|
622 +|Baud rate|9600~~115200|
623 +|Data bit|7/8|
624 +|Parity|EVEN/Odd/None|
625 +|Stop bit|1/2|
626 +|PLC station No.|1~~255|
627 +
628 +**2)Address List**
629 +
630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
632 +|Y|Y|Y o|0~~303237|
633 +|M|M|M d|0~~99999|
634 +|T|T|T d|0~~99999|
635 +|C|C|C d|0~~99999|
636 +|S|S|S d|0~~99999|
637 +|SM|SM|SM d|8000~~9999|
638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
639 +|Y|Y|Y o|0~~303237|
640 +|M|M|M d|0~~99999|
641 +|T|T|T d|0~~99999|
642 +|C|C|C d|0~~199|
643 +|D|D|D d|0~~7999|
644 +|S|S|S d|0~~99999|
645 +|SD|SD|SD d|8000~~9999|
646 +
647 +**3)Configure the communication protocol**
648 +
649 +[[image:image-20220825102844-3.png]]
650 +
651 +**4)Cable Wiring**
652 +
653 +* **RS422**
654 +
655 +[[image:image-20220825103350-4.png]]
656 +
657 +[[image:image-20220825100845-4.png]]
658 +
659 +
660 +== **FX3U,3G,3GA Serial Protocol** ==
661 +
662 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
663 +
664 +**1)V-BOX Settings**
665 +
666 +|**Item**|**Settings**|**Note**
667 +|Protocol|Mitsubishi FX3U/3G/3GA|
668 +|Connection|RS422/RS485/RS232|
669 +|Baud rate|9600~~115200|
670 +|Data bit|7/8|
671 +|Parity|EVEN/Odd/None|
672 +|Stop bit|1/2|
673 +|PLC station No.|1~~255|
674 +
675 +**2)Address List**
676 +
677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
678 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
679 +|Y|Y|Y o|0~~303237|
680 +|M|M|M d|0~~99999|
681 +|T|T|T d|0~~99999|
682 +|C|C|C d|0~~99999|
683 +|S|S|S d|0~~99999|
684 +|SM|SM|SM d|8000~~9999|
685 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
686 +|Y|Y|Y o|0~~303237|
687 +|M|M|M d|0~~99999|
688 +|T|T|T d|0~~99999|
689 +|C|C|C d|0~~199|
690 +|D|D|D d|0~~7999|
691 +|S|S|S d|0~~99999|
692 +|SD|SD|SD d|8000~~9999|
693 +
694 +**3)Configure the communication protocol**
695 +
696 +[[image:image-20220825102649-2.png]]
697 +
698 +**4)Cable Wiring**
699 +
700 +* **RS422**
701 +
702 +[[image:image-20220825103421-5.png]]
703 +
704 +[[image:image-20220825100845-4.png]]
705 +
706 +
707 +== **FX5U Serial Protocol** ==
708 +
709 +Mitsubishi FX5U series PLC
710 +
711 +**1)V-BOX Settings**
712 +
713 +|**Item**|**Settings**|**Note**
714 +|Protocol|Mitsubishi FX5U|
715 +|Connection|RS422/RS485|
716 +|Baud rate|9600|
717 +|Data bit|7|
718 +|Parity|Odd|
719 +|Stop bit|1|
720 +|PLC station No.|1~~255|Need to be the same as PLC settings
721 +
722 +**2)Address List**
723 +
724 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
725 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
726 +|Y|Y|Y o|0~~303237|
727 +|M|M|M d|0~~99999|
728 +|B|B|B h|0~~7FFF|
729 +|F|F|F d|0~~32767|
730 +|SB|SB|SB h|0~~7FFF|
731 +|TS|TS|TS d|0~~1023|
732 +|TC|TC|TC d|0~~1023|
733 +|STS|STS|STS d|0~~1023|
734 +|STC|STC|STS d|0~~1023|
735 +|CS|CS|CS d|0~~1023|
736 +|CC|CC|CC d|0~~1023|
737 +|SM|SM|SM d|0~~9999|
738 +|L|L|L d|0~~32767|
739 +|S|S|S d|0~~4095|
740 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
741 +|TN|TN|TN d|0~~1023|
742 +|STN|STN|STN d|0~~1023|
743 +|CN|CN|CN d|0~~1023|
744 +|R|R|R d|0~~32767|
745 +|SW|SW|SW h|0~~7FFF|
746 +|Z|Z|Z d|0~~23|
747 +|D|D|D d|0~~7999|
748 +|SD|SD|SD d|0~~11999|
749 +
750 +**3)PLC Settings (GX Works 3)**
751 +
752 +Create a blank FX5U project
753 +
754 +Find the 485 serial port module in the system navigation bar and double click to enter the settings.
755 +
756 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
757 +
758 +Select protocol in the setting item, and set parameters.
759 +
760 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
761 +
762 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
763 +
764 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
765 +
766 +Click the [Apply] button to finish the setting.
767 +
768 +Click download and select the items as below, then click [execute] to download the configuration to PLC.
769 +
770 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
771 +
772 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
773 +
774 +Done.
775 +
776 +**4)Configure the communication protocol**
777 +
778 +[[image:image-20220825104904-1.png]]
779 +
780 +**5)Cable Wiring**
781 +
782 +
783 +* **RS422**
784 +
785 +[[image:image-20220825105105-2.png]]
786 +
787 +[[image:image-20220825105533-3.png]]
788 +
789 +== **FX5U Ethernet Protocol** ==
790 +
791 +Mitsubishi FX5U series PLC
792 +
793 +**1)V-BOX Settings**
794 +
795 +|**Items**|**Settings**|**Note**
796 +|Protocol|Mitsubishi FX5U|
797 +|Connection|Ethernet|
798 +|Port No.|5002|Must be the same as the PLC setting
799 +|PLC station No.|0|
800 +
801 +**2)Address List**
802 +
803 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
804 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
805 +|Y|Y|Y o|0~~303237|
806 +|M|M|M d|0~~99999|
807 +|B|B|B h|0~~7FFF|
808 +|F|F|F d|0~~32767|
809 +|SB|SB|SB h|0~~7FFF|
810 +|TS|TS|TS d|0~~1023|
811 +|TC|TC|TC d|0~~1023|
812 +|STS|STS|STS d|0~~1023|
813 +|STC|STC|STS d|0~~1023|
814 +|CS|CS|CS d|0~~1023|
815 +|CC|CC|CC d|0~~1023|
816 +|SM|SM|SM d|0~~9999|
817 +|L|L|L d|0~~32767|
818 +|S|S|S d|0~~4095|
819 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
820 +|TN|TN|TN d|0~~1023|
821 +|STN|STN|STN d|0~~1023|
822 +|CN|CN|CN d|0~~1023|
823 +|R|R|R d|0~~32767|
824 +|SW|SW|SW h|0~~7FFF|
825 +|Z|Z|Z d|0~~23|
826 +|D|D|D d|0~~7999|
827 +|SD|SD|SD d|0~~11999|
828 +
829 +**3)PLC Settings (GX Works 3)**
830 +
831 +Find the [Ethernet port] in the navigation area.
832 +
833 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
834 +
835 +Select [Own Node Settings] in the [Setting Item List];
836 +
837 +Set [IP Address], [Subnet Mask], [Default Gateway];
838 +
839 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
840 +
841 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
842 +
843 +Select [SLMP Connection Module] and add into host station as below picture shows;
844 +
845 +Set Port number as 5002 (this is necessary settings);
846 +
847 +Click [Close with Reflecting the Setting] to save and close window;
848 +
849 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
850 +
851 +Click [Apply] to completed Etherenet settings;
852 +
853 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
854 +
855 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
856 +
857 +**4)Configure the communication protocol**
858 +
859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
860 +
861 +**5)电缆布线**
862 +
863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
864 +
865 +
866 +== **L02 Serial Protocol** ==
867 +
868 +Mitsubishi L02 series CPU built-in serial port.
869 +
870 +**1)V-BOX Settings**
871 +
872 +|**Item**|**Settings**|**Note**
873 +|Protocol|Mitsubishi L02|
874 +|Connection|RS422|
875 +|Baud rate|115200|
876 +|Data bit|8|
877 +|Parity|Odd|
878 +|Stop bit|1|
879 +|PLC station No.|1~~255|Need to be the same as PLC settings
880 +
881 +**2)Address List**
882 +
883 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
884 +|Bit|X|X|X h|0~~FFFF|
885 +|Bit|Y|Y|Y h|0~~FFFF|
886 +|Bit|M|M|M d|0~~9999|
887 +|Bit|L|L|L d|0~~9999|
888 +|Bit|F|F|F d|0~~9999|
889 +|Bit|B|B|B h|0~~FFFF|
890 +|Bit|V|V|V d|0~~2047|
891 +|Bit|TC|TC|TC d|0~~9999|
892 +|Bit|SS|SS|SS d|0~~9999|
893 +|Bit|SC|SC|SC d|0~~9999|
894 +|Bit|CS|CS|CS d|0~~9999|
895 +|Bit|CC|CC|CC d|0~~9999|
896 +|Bit|SB|SB|SB h|0~~FFFF|
897 +|Bit|SM|SM|SM d|0~~2047|
898 +|Bit|STS|STS|STS d|0~~1023|
899 +|Bit|S|S|S d|0~~9999|
900 +|Bit|DX|DX|DX h|0~~FFFF|
901 +|Bit|DY|DY|DY h|0~~FFFF|
902 +|Bit|TS|TS|TS d|0~~9999|
903 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
904 +|Word|W|W|W h|0~~FFFF|
905 +|Word|TN|TN|TN d|0~~99999|
906 +|Word|SN|SN|SN d|0~~99999|
907 +|Word|CN|CN|CN d|0~~99999|
908 +|Word|R|R|R d|0~~99999|
909 +|Word|SW|SW|SW h|0~~FFFF|
910 +|Word|Z|Z|Z d|0~~99999|
911 +|Word|ZR|ZR|ZR h|0~~FFFF|
912 +|Word|D|D|D d|0~~99999|
913 +
914 +**3)Communication Settings**
915 +
916 +[[image:image-20220825160648-3.png]]
917 +
918 +**4)Cable Wiring**
919 +
920 +* **RS422**
921 +
922 +[[image:image-20220825161612-8.png]]
923 +
924 +[[image:image-20220825160820-4.png]]
925 +
926 +== **L02 Ethernet Protocol** ==
927 +
928 +Mitsubishi L series CPU built-in Ethernet port.
929 +
930 +**1)V-BOX Settings**
931 +
932 +|**Items**|**Settings**|**Note**
933 +|Protocol|MIT L02 CPU MELSEC|
934 +|Connection|Ethernet|
935 +|Port No.|1025|Must be the same as the PLC setting
936 +|PLC station No.|0|Must be the same as the PLC setting
937 +
938 +**2)Address List**
939 +
940 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
941 +|Bit|X|X|X h|0~~FFFF|
942 +|Bit|Y|Y|Y h|0~~FFFF|
943 +|Bit|M|M|M d|0~~9999|
944 +|Bit|L|L|L d|0~~9999|
945 +|Bit|F|F|F d|0~~9999|
946 +|Bit|B|B|B h|0~~FFFF|
947 +|Bit|V|V|V d|0~~2047|
948 +|Bit|TC|TC|TC d|0~~9999|
949 +|Bit|SS|SS|SS d|0~~9999|
950 +|Bit|SC|SC|SC d|0~~9999|
951 +|Bit|CS|CS|CS d|0~~9999|
952 +|Bit|CC|CC|CC d|0~~9999|
953 +|Bit|SB|SB|SB h|0~~FFFF|
954 +|Bit|SM|SM|SM d|0~~2047|
955 +|Bit|STS|STS|STS d|0~~1023|
956 +|Bit|S|S|S d|0~~9999|
957 +|Bit|DX|DX|DX h|0~~FFFF|
958 +|Bit|DY|DY|DY h|0~~FFFF|
959 +|Bit|TS|TS|TS d|0~~9999|
960 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
961 +|Word|W|W|W h|0~~FFFF|
962 +|Word|TN|TN|TN d|0~~99999|
963 +|Word|SN|SN|SN d|0~~99999|
964 +|Word|CN|CN|CN d|0~~99999|
965 +|Word|R|R|R d|0~~99999|
966 +|Word|SW|SW|SW h|0~~FFFF|
967 +|Word|Z|Z|Z d|0~~99999|
968 +|Word|ZR|ZR|ZR h|0~~FFFF|
969 +|Word|D|D|D d|0~~99999|
970 +
971 +**3)PLC Settings (GX Works2 )**
972 +
973 +Create a project
974 +
975 +Set PLC IP, subnet mask and gateway;
976 +
977 +Select [Binary Code] as communication data code;
978 +
979 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
980 +
981 +Set PLC port number, for example 1025
982 +
983 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
984 +
985 +Save settings;
986 +
987 +Download project into PLC device;
988 +
989 +Restart PLC device;
990 +
991 +**4)Configure the communication protocol**
992 +
993 +[[image:image-20220825142659-1.png]]
994 +
995 +**5)Cable Wiring**
996 +
997 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
998 +
999 +== **QJ71E71 Ethernet Protocol** ==
1000 +
1001 +Mitsubishi QJ71E71 Ethernet communication module;
1002 +
1003 +**1)V-BOX Settings**
1004 +
1005 +|**Items**|**Settings**|**Note**
1006 +|Protocol|MIT QJ71E71 MELSEC|
1007 +|Connection|Ethernet|
1008 +|Port No.|1025|Must be the same as the PLC setting
1009 +|PLC station No.|0|Must be the same as the PLC setting
1010 +
1011 +**2)Address List**
1012 +
1013 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1014 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
1015 +|Y|Y|Y h|0~~1FFF|
1016 +|M|M|M d|0~~99999|
1017 +|L|L|L d|0~~8191|
1018 +|F|F|F d|0~~2047|
1019 +|B|B|B h|0~~1FFF|
1020 +|V|V|V d|0~~2047|
1021 +|TS|TS|TS d|0~~2047|
1022 +|TC|TC|TC d|0~~2047|
1023 +|SS|SS|SS d|0~~2047|
1024 +|SC|SC|SC d|0~~2047|
1025 +|CS|CS|CS d|0~~1023|
1026 +|CC|CC|CC d|0~~1023|
1027 +|SB|SB|SB h|0~~7FF|
1028 +|S|S|S d|0~~8191|
1029 +|DX|DX|DX h|0~~1FFF|
1030 +|DY|DY|DY h|0~~1FFF|
1031 +|SM|SM|SM d|8000~~9999|
1032 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
1033 +|D|D|D d|0~~12287|
1034 +|W|W|W h|0~~1FFF|
1035 +|TN|TN|TN d|0~~2047|
1036 +|SN|SN|SN d|0~~2047|
1037 +|CN|CN|CN d|0~~1023|
1038 +|R|R|R d|0~~32767|
1039 +|SW|SW|SW h|0~~7FF|
1040 +|Z|Z|Z d|0~~15|
1041 +|ZR|ZR|ZR h|0~~FE7FF|
1042 +
1043 +**3)PLC Settings(GX Works2)**
1044 +
1045 +* Click [Ethernet/CC IE/MELSECNET];
1046 +* Please select [Ethernet] as network type;
1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1048 +* Select [Online] as Mode;
1049 +* Click [Operation setting] to set IP;
1050 +* Select [Binary Code] as [Communication Data Code];
1051 +* Set protocol: TCP;
1052 +* Set [unpassive] in [Open system];
1053 +* Set [receive] in [Fixed buffer];
1054 +* Set [procedure Exist] in [Fixed buffer communication];
1055 +* Disable [Pairing open];
1056 +* Set [No confirm] in [Existence confirmation];
1057 +* Host station port number: 1025;
1058 +* Save settings;
1059 +* Download project into PLC and restart it
1060 +
1061 +**4)Configure the communication protocol**
1062 +
1063 +[[image:image-20220825143728-1.png]]
1064 +
1065 +**5)Cable Wiring**
1066 +
1067 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1068 +
1069 += Create communication with **Delta PLC** =
1070 +
452 452  == **DVP Ethernet Protocol** ==
453 453  
454 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
455 455  
456 -== **DVP Serial Protocol** ==
1075 +== **DVP serial protocol** ==
457 457  
458 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
459 459  
460 -= **Omron PLC** =
1079 +== **AS Ethernet Protocol** ==
461 461  
462 -== **CP1 Series Protocol** ==
1081 +**1)V-BOX Settings**
463 463  
464 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1083 +|=**Items**|=**Settings**|=**Note**
1084 +|Protocol|DELTA AS300 MODBUS TCP|
1085 +|Connection|Ethernet|
1086 +|Port No.|502|
1087 +|Device No.|1|
1088 +|HMI No.|0|
465 465  
466 -== **CJ2M Series Protocol** ==
1090 +**2)Address List**
467 467  
468 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1093 +|Bit|X|X|X d|0~~63|
1094 +|Bit|Y|Y|Y d|0~~63|
1095 +|Bit|D|D|D d|0~~29999|
1096 +|Bit|M|M|M d|0~~8191|
1097 +|Bit|SM|SM|SM d|0~~4095|
1098 +|Bit|S|S|S h|0~~2047|
1099 +|Bit|T|T|T d|0~~511|
1100 +|Bit|C|C|C d|0~~511|
1101 +|Bit|HC|HC|HC d|0~~255|
1102 +|Word|X|X|X h|0~~63|
1103 +|Word|Y|Y|Y d|0~~63|
1104 +|Word|SR|SR|SR d|0~~2047|
1105 +|Word|D|D|D d|0~~29999|
1106 +|Word|T|T|T d|0~~511|
1107 +|Word|C|C|C h|0~~511|
1108 +|Word|E|E|E d|0~~9|
469 469  
470 -= **Modbus RTU** =
1110 +**3)Configure the communication protocol**
471 471  
472 -== **V-BOX as master** ==
473 473  
474 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
1113 +[[image:image-20220831160010-4.png]]
475 475  
476 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1115 +**4)Cable Wiring**
477 477  
1117 +Figure
1118 +
1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1120 +
1121 +Pin Definition Diagram
1122 +
1123 +[[image:image-20220831155157-3.png]]
1124 +
1125 += Create communication with **Omron PLC** =
1126 +
1127 +== **CP1 Series Protocol ** ==
1128 +
1129 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1130 +
1131 +== **CP2M Series Protocol** ==
1132 +
1133 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1134 +
1135 +
1136 +== **EC55 Series Protocol** ==
1137 +
1138 +Supported device: EC55 temperature instrument
1139 +
1140 +**1)V-BOX Settings**
1141 +
1142 +|**Items**|**Settings**|**Note**
1143 +|Protocol|Omron EC55|
1144 +|Connection|RS485 (9600, 2, 7, EVEN)|
1145 +|Port No.|None|
1146 +|PLC station No.|0|
1147 +
1148 +**2)Address List**
1149 +
1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1157 +|CP|-|0-6|Read controller intrinsic property
1158 +|CS|-|0-2|Read controller states
1159 +|CA|-|0-17|Action command
1160 +
1161 +**3)Device Settings**
1162 +
1163 +Omron E5CC PLC configuration
1164 +
1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1166 +
1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1168 +
1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1170 +
1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1172 +
1173 +**✎Note:** The communication settings for HMI should be consistent with this setting.
1174 +
1175 +**4)Configure the communication protocol**
1176 +
1177 +[[image:image-20220831161041-1.png]]
1178 +
1179 +**5)Cable Wiring**
1180 +
1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1182 +
1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1184 +
1185 +**✎Note:**
1186 +
1187 +* COM3 only available in PI8000/PI9000 series.
1188 +* CA address could not support continuous writing function;
1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1195 +* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1196 +
1197 += Create communication with **Modbus RTU** =
1198 +
1199 +== **V-BOX as Slave** ==
1200 +
1201 +Select the protocol "Modbus RTU Slave (All Fuction)",
1202 +
1203 +Then set baud rate, port, stop bits, data bits, parity.
1204 +
478 478  (% style="text-align:center" %)
479 479  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
480 480  
481 -== **V-BOX as slave** ==
1208 +== **V-BOX as Master** ==
482 482  
483 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
1210 +Select the protocol "Modbus RTU Master",
484 484  
485 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1212 +Then set baud rate, port, stop bits, data bits, parity
486 486  
487 487  (% style="text-align:center" %)
488 488  [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
489 489  
490 -**Address List**
1217 +**address list**
491 491  
492 492  (% class="table-bordered" %)
493 -|**Type**|**Register**|**Function code & Description**
494 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1220 +|**type**|**register**|**Function code and description**
1221 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
495 495  |06 (write single register: write a binary value to a holding register)
496 496  |10 (write values to multiple addresses )
497 497  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
image-20220824152217-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.6 KB
Content
image-20220824152928-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +137.8 KB
Content
image-20220824161345-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824161450-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162339-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162342-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162459-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
image-20220824163110-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.3 KB
Content
image-20220824163305-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.5 KB
Content
image-20220824163448-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.8 KB
Content
image-20220824164346-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.2 KB
Content
image-20220825100807-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100814-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100845-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +403.6 KB
Content
image-20220825102641-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220825102649-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220825102844-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.8 KB
Content
image-20220825103350-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +65.9 KB
Content
image-20220825103421-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.0 KB
Content
image-20220825104904-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.5 KB
Content
image-20220825105105-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +78.5 KB
Content
image-20220825105533-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.8 KB
Content
image-20220825112403-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
image-20220825142437-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.5 KB
Content
image-20220825142659-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content
image-20220825143728-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.7 KB
Content
image-20220825160227-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +148.8 KB
Content
image-20220825160341-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.7 KB
Content
image-20220825160648-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
image-20220825160820-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20220825160925-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825160929-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825161440-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.7 KB
Content
image-20220825161612-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
image-20220831155101-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +59.6 KB
Content
image-20220831160055-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.5 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.1 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +27.0 KB
Content