Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,13 +108,13 @@ 108 108 109 109 **1)Hardware wiring diagram** 110 110 111 -This example introduces V-BOXwith LX5V PLC to establish communication through serial port. The connection diagram is as follows:111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 112 112 113 113 [[image:image-20220824142546-2.png]] 114 114 115 115 [[image:image-20220824142643-3.png]] 116 116 117 -The above are all the steps for establishing serial port communication between V-BOXwith LX5V PLC.117 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 118 118 119 119 120 120 == **LX5V-N Ethernet protocol** == ... ... @@ -148,37 +148,48 @@ 148 148 149 149 **4)Registers list** 150 150 151 -[[image:image-202208221 72730-4.png]]151 +[[image:image-20220811102219-3.png]] 152 152 153 - (% id="cke_bm_22473S" style="display:none" %)****(%%)**V-BOXsoftware configuration**153 +**HMI software configuration** 154 154 155 -**1) V-BOXprogramming software**155 +**1)HMI programming software** 156 156 157 - [[image:image-202208 24104124-1.png]]157 + [[image:image-20220810171237-4.png]] 158 158 159 -**2) V-NETadddevice**159 +**2)New HMI project** 160 160 161 - Open V-NET client software → add device.As shownin the figure below,click "+" intheorder of steps,andtheAdd Device window will pop up,entertheaccesskey, password and remark, toadd thedevice.161 +Click New Project and select the HMI model. 162 162 163 -[[image:image-202208 24104909-2.png]]163 +[[image:image-20220810172010-5.png]] 164 164 165 165 **3)Set communication port parameters** 166 166 167 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 167 167 168 - ClickCommunication to configure the LX5V plc protocol andIP address.169 +HMI IP address:192.168.39.201 169 169 170 - [[image:image-20220824144619-1.png]]171 +default gateway:192.168.39.1 171 171 173 +subnet mask:255.255.255.0 174 + 175 +[[image:image-20220811170753-2.png]] 176 + 177 +Next, click Communication Settings to configure the IP of the HMI communication object. 178 + 179 +[[image:image-20220811163047-1.png]] 180 + 172 172 **hardware connection** 173 173 174 174 **1)Hardware wiring diagram** 175 175 176 -This example introduces V-BOXwith LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:185 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 177 177 178 -[[image:image-202208 24151127-2.png]]187 +[[image:image-20220811170248-1.png]] 179 179 180 -The above are all the steps for establishing ethernet communication between V-BOXwith LX5V PLC.189 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 181 181 191 +(% style="text-align:center" %) 192 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 182 182 183 183 = **Rockwell PLC** = 184 184
- image-20220824144619-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.2 KB - Content
- image-20220824151127-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.5 KB - Content