Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -** HMISettings**7 +**1)PLC Settings** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,7 +15,7 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**Address List** 18 +**2)PLC Address List** 19 19 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| ... ... @@ -33,8 +33,12 @@ 33 33 |S|S|S d|0~~99999| 34 34 |SD|SD|SD d|8000~~9999| 35 35 36 -**C ableWiring**36 +**3)Configure the communication protocol** 37 37 38 +[[image:image-20220824152217-1.png]] 39 + 40 +**4)hardware connection** 41 + 38 38 * **RS422** 39 39 40 40 [[image:image-20220824120614-5.png]] ... ... @@ -45,7 +45,7 @@ 45 45 46 46 == **LX5V Serial Protocol** == 47 47 48 -This example introduces the establishment of serial port communication between WeconV-BOX and LX5V. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 49 49 50 50 **Software configuration of PLC** 51 51 ... ... @@ -89,7 +89,6 @@ 89 89 90 90 [[image:image-20220824104909-2.png]] 91 91 92 - 93 93 **3)Set communication port parameters** 94 94 95 95 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -108,8 +108,6 @@ 108 108 109 109 **1)Hardware wiring diagram** 110 110 111 -This example introduces V-BOX with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 112 - 113 113 [[image:image-20220824142546-2.png]] 114 114 115 115 [[image:image-20220824142643-3.png]] ... ... @@ -116,10 +116,9 @@ 116 116 117 117 The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 118 118 119 - 120 120 == **LX5V-N Ethernet protocol** == 121 121 122 -This example introduces the establishment of Ethernet communication between WeconHMIand LX5V-N. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.122 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 123 123 124 124 **Software configuration of PLC** 125 125 ... ... @@ -145,7 +145,6 @@ 145 145 146 146 [[image:image-20220824143744-2.png]] 147 147 148 - 149 149 **4)Registers list** 150 150 151 151 [[image:image-20220822172730-4.png]] ... ... @@ -162,9 +162,8 @@ 162 162 163 163 [[image:image-20220824104909-2.png]] 164 164 165 -**3)Set communication portparameters**164 +**3)Set communication Protocol** 166 166 167 - 168 168 Click Communication to configure the LX5V plc protocol and IP address. 169 169 170 170 [[image:image-20220824144619-1.png]] ... ... @@ -173,13 +173,10 @@ 173 173 174 174 **1)Hardware wiring diagram** 175 175 176 -This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 177 - 178 178 [[image:image-20220824151127-2.png]] 179 179 180 180 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 181 181 182 - 183 183 = **Rockwell PLC** = 184 184 185 185 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == ... ... @@ -186,10 +186,10 @@ 186 186 187 187 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 188 188 189 -** HMISettings**184 +**1)PLC Settings** 190 190 191 191 |**Item**|**Settings**|**Note** 192 -|Protocol|Allen-Bradlley MicroLogix|187 +|Protocol|Allen-Bradlley DF1 Advanced| 193 193 |Connection|RS232| 194 194 |Baud rate|19200| 195 195 |Data bit|8| ... ... @@ -197,7 +197,7 @@ 197 197 |Stop bit|1| 198 198 |PLC station No.|1| 199 199 200 -**Address List** 195 +**2)Address List** 201 201 202 202 |**Type**|**Device registers**|**Format**|**Range**|**Note** 203 203 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -215,12 +215,12 @@ 215 215 |T|T nnhh|0~~ffff 216 216 |R|R nnhh|0~~ffff 217 217 218 -**C ableWiring**213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 219 219 215 +**4)Configure the communication protocol** 216 + 220 220 [[image:image-20220824110724-1.png]] 221 221 222 - 223 - 224 224 == **CompactLogix Protocol** == 225 225 226 226 ((( ... ... @@ -434,9 +434,66 @@ 434 434 == **S7-200 Smart Ethernet Protocol** == 435 435 436 436 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 + 433 + 434 +== ** S7-300 Ethernet Protocol** == 435 + 436 +Supported Series: Siemens S7-300 series PLC 437 + 438 +**1)PLC Setting** 439 + 440 +|**Items**|**Settings**|**Note** 441 +|Protocol|Simens S7-300 Ethernet| 442 +|Connection|Ethernet| 443 +|Port No.|102| 444 +|PLC station No.|2|Need to be same as the PLC setting 445 + 446 +**2)Address List** 447 + 448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 +|Q|Q|Q ddddd.o|0.0~~99999.7| 451 +|M|M|M ddddd.o|0.0~~99999.7| 452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 +nn: block number; 454 + 455 +dddd: address; 437 437 ))) 457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 +|Q|QW|QW ddddd|0~~99999| 459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 +|MW|MW ddddd|0~~99999|((( 461 +MW0=MB(0~~1) 462 + 463 +MW2=MB(2~~3) 464 + 465 +Address value is a multiple of 2 438 438 ))) 467 +|MD|MD ddddd|0~~99999|((( 468 +MD0=MB(0~~3) 439 439 470 +MD4=MB(4~~7) 471 + 472 +Address value is a multiple of 4 473 +))) 474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 +nn: block number; 476 + 477 +dddd: address 478 +))) 479 +|DBxDBW|DBxDBW nndddd|0~~99999999 480 +|DBxDBD|DBxDBD nndddd|0~~99999999 481 + 482 +**3)Configure the communication protocol** 483 + 484 +[[image:image-20220824161345-1.png]] 485 + 486 +**Cable Wiring** 487 + 488 +[[image:image-20220824161450-2.png]] 489 +))) 490 +))) 491 + 440 440 == **S7-1200 Ethernet Protocol** == 441 441 442 442 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
- image-20220824152217-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.6 KB - Content
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.8 KB - Content
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content