Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,27 +108,31 @@ 108 108 109 109 **1)Hardware wiring diagram** 110 110 111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 112 + 111 111 [[image:image-20220824142546-2.png]] 112 112 113 113 [[image:image-20220824142643-3.png]] 114 114 115 -The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 116 116 118 + 119 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 120 + 117 117 == **LX5V-N Ethernet protocol** == 118 118 119 -This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V -N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.123 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 120 120 121 121 **Software configuration of PLC** 122 122 123 123 **1)PLC programming software** 124 124 125 -[[image:image-202208 24142722-1.png]]129 +[[image:image-20220810164710-1.png]] 126 126 127 127 **2)New PLC project** 128 128 129 129 Click New Project and select the PLC model. 130 130 131 -[[image:image-202208 24143613-1.png]]135 +[[image:image-20220811115454-1.png]] 132 132 133 133 **3)Set Ethernet port parameters** 134 134 ... ... @@ -140,42 +140,52 @@ 140 140 141 141 subnet mask:255.255.255.0 142 142 143 -[[image:image-202208 24143744-2.png]]147 +[[image:image-20220811140530-2.png]] 144 144 145 - 146 146 **4)Registers list** 147 147 148 -[[image:image-202208221 72730-4.png]]151 +[[image:image-20220811102219-3.png]] 149 149 150 - (% id="cke_bm_22473S" style="display:none" %)****(%%)**V-BOXsoftware configuration**153 +**HMI software configuration** 151 151 152 -**1) V-BOXprogramming software**155 +**1)HMI programming software** 153 153 154 - [[image:image-202208 24104124-1.png]]157 + [[image:image-20220810171237-4.png]] 155 155 156 -**2) V-NETadddevice**159 +**2)New HMI project** 157 157 158 - Open V-NET client software → add device.As shownin the figure below,click "+" intheorder of steps,andtheAdd Device window will pop up,entertheaccesskey, password and remark, toadd thedevice.161 +Click New Project and select the HMI model. 159 159 160 -[[image:image-202208 24104909-2.png]]163 +[[image:image-20220810172010-5.png]] 161 161 162 162 **3)Set communication port parameters** 163 163 167 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 164 164 165 - ClickCommunication to configure the LX5V plc protocol andIP address.169 +HMI IP address:192.168.39.201 166 166 167 - [[image:image-20220824144619-1.png]]171 +default gateway:192.168.39.1 168 168 173 +subnet mask:255.255.255.0 174 + 175 +[[image:image-20220811170753-2.png]] 176 + 177 +Next, click Communication Settings to configure the IP of the HMI communication object. 178 + 179 +[[image:image-20220811163047-1.png]] 180 + 169 169 **hardware connection** 170 170 171 171 **1)Hardware wiring diagram** 172 172 173 -This example introduces V-BOXwith LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:185 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 174 174 175 -[[image:image-202208 24151127-2.png]]187 +[[image:image-20220811170248-1.png]] 176 176 177 -The above are all the steps for establishing ethernet communication between V-BOXwith LX5V PLC.189 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 178 178 191 +(% style="text-align:center" %) 192 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 179 179 180 180 = **Rockwell PLC** = 181 181
- image-20220824143613-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -206.2 KB - Content
- image-20220824143744-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.0 KB - Content
- image-20220824144619-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.2 KB - Content
- image-20220824151127-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.5 KB - Content