... ... @@ -4,7 +4,7 @@
4 4  
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**HMI Settings**
7 +**1)PLC Settings**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,7 +15,7 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**Address List**
18 +**2)PLC Address List**
19 19  
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
... ... @@ -33,8 +33,12 @@
33 33  |S|S|S d|0~~99999|
34 34  |SD|SD|SD d|8000~~9999|
35 35  
36 -**Cable Wiring**
36 +**3)Configure the communication protocol**
37 37  
38 +[[image:image-20220824152217-1.png]]
39 +
40 +**4)hardware connection**
41 +
38 38  * **RS422**
39 39  
40 40   [[image:image-20220824120614-5.png]]
... ... @@ -45,7 +45,7 @@
45 45  
46 46  == **LX5V Serial Protocol** ==
47 47  
48 -This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
49 49  
50 50  **Software configuration of PLC**
51 51  
... ... @@ -89,7 +89,6 @@
89 89  
90 90  [[image:image-20220824104909-2.png]]
91 91  
92 -
93 93  **3)Set communication port parameters**
94 94  
95 95  Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
... ... @@ -116,7 +116,7 @@
116 116  
117 117  == **LX5V-N Ethernet protocol** ==
118 118  
119 -This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
122 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
120 120  
121 121  **Software configuration of PLC**
122 122  
... ... @@ -142,7 +142,6 @@
142 142  
143 143  [[image:image-20220824143744-2.png]]
144 144  
145 -
146 146  **4)Registers list**
147 147  
148 148  [[image:image-20220822172730-4.png]]
... ... @@ -159,9 +159,8 @@
159 159  
160 160  [[image:image-20220824104909-2.png]]
161 161  
162 -**3)Set communication port parameters**
164 +**3)Set communication Protocol**
163 163  
164 -
165 165  Click Communication to configure the LX5V plc protocol and IP address.
166 166  
167 167  [[image:image-20220824144619-1.png]]
... ... @@ -170,13 +170,10 @@
170 170  
171 171  **1)Hardware wiring diagram**
172 172  
173 -This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
174 -
175 175  [[image:image-20220824151127-2.png]]
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -
180 180  = **Rockwell PLC** =
181 181  
182 182  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
... ... @@ -183,10 +183,10 @@
183 183  
184 184  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
185 185  
186 -**HMI Settings**
184 +**1)PLC Settings**
187 187  
188 188  |**Item**|**Settings**|**Note**
189 -|Protocol|Allen-Bradlley MicroLogix|
187 +|Protocol|Allen-Bradlley DF1 Advanced|
190 190  |Connection|RS232|
191 191  |Baud rate|19200|
192 192  |Data bit|8|
... ... @@ -194,7 +194,7 @@
194 194  |Stop bit|1|
195 195  |PLC station No.|1|
196 196  
197 -**Address List**
195 +**2)Address List**
198 198  
199 199  |**Type**|**Device registers**|**Format**|**Range**|**Note**
200 200  |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
... ... @@ -212,12 +212,12 @@
212 212  |T|T nnhh|0~~ffff
213 213  |R|R nnhh|0~~ffff
214 214  
215 -**Cable Wiring**
213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]]
216 216  
215 +**4)Configure the communication protocol**
216 +
217 217  [[image:image-20220824110724-1.png]]
218 218  
219 -
220 -
221 221  == **CompactLogix Protocol** ==
222 222  
223 223  (((
image-20220824152217-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.6 KB
Content
image-20220824152928-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +137.8 KB
Content