Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -** HMISettings**7 +**1)PLC Settings** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,7 +15,7 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**Address List** 18 +**2)PLC Address List** 19 19 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| ... ... @@ -33,8 +33,12 @@ 33 33 |S|S|S d|0~~99999| 34 34 |SD|SD|SD d|8000~~9999| 35 35 36 -**C ableWiring**36 +**3)Configure the communication protocol** 37 37 38 +[[image:image-20220824152217-1.png]] 39 + 40 +**4)hardware connection** 41 + 38 38 * **RS422** 39 39 40 40 [[image:image-20220824120614-5.png]] ... ... @@ -45,7 +45,7 @@ 45 45 46 46 == **LX5V Serial Protocol** == 47 47 48 -This example introduces the establishment of serial port communication between WeconV-BOX and LX5V. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 49 49 50 50 **Software configuration of PLC** 51 51 ... ... @@ -89,7 +89,6 @@ 89 89 90 90 [[image:image-20220824104909-2.png]] 91 91 92 - 93 93 **3)Set communication port parameters** 94 94 95 95 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -142,7 +142,6 @@ 142 142 143 143 [[image:image-20220824143744-2.png]] 144 144 145 - 146 146 **4)Registers list** 147 147 148 148 [[image:image-20220822172730-4.png]] ... ... @@ -159,9 +159,8 @@ 159 159 160 160 [[image:image-20220824104909-2.png]] 161 161 162 -**3)Set communication portparameters**164 +**3)Set communication Protocol** 163 163 164 - 165 165 Click Communication to configure the LX5V plc protocol and IP address. 166 166 167 167 [[image:image-20220824144619-1.png]] ... ... @@ -170,8 +170,6 @@ 170 170 171 171 **1)Hardware wiring diagram** 172 172 173 -This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 174 - 175 175 [[image:image-20220824151127-2.png]] 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. ... ... @@ -182,10 +182,10 @@ 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 -** HMISettings**184 +**1)PLC Settings** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradlley MicroLogix|187 +|Protocol|Allen-Bradlley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -193,7 +193,7 @@ 193 193 |Stop bit|1| 194 194 |PLC station No.|1| 195 195 196 -**Address List** 195 +**2)Address List** 197 197 198 198 |**Type**|**Device registers**|**Format**|**Range**|**Note** 199 199 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -211,12 +211,12 @@ 211 211 |T|T nnhh|0~~ffff 212 212 |R|R nnhh|0~~ffff 213 213 214 -**C ableWiring**213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 215 215 215 +**4)Configure the communication protocol** 216 + 216 216 [[image:image-20220824110724-1.png]] 217 217 218 - 219 - 220 220 == **CompactLogix Protocol** == 221 221 222 222 ((( ... ... @@ -430,13 +430,195 @@ 430 430 == **S7-200 Smart Ethernet Protocol** == 431 431 432 432 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 + 433 + 434 +== ** S7-300 Ethernet Protocol** == 435 + 436 +Supported Series: Siemens S7-300 series PLC 437 + 438 +**1)PLC Setting** 439 + 440 +|**Items**|**Settings**|**Note** 441 +|Protocol|Simens S7-300 Ethernet| 442 +|Connection|Ethernet| 443 +|Port No.|102| 444 +|PLC station No.|2|Need to be same as the PLC setting 445 + 446 +**2)Address List** 447 + 448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 +|Q|Q|Q ddddd.o|0.0~~99999.7| 451 +|M|M|M ddddd.o|0.0~~99999.7| 452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 +nn: block number; 454 + 455 +dddd: address; 433 433 ))) 457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 +|Q|QW|QW ddddd|0~~99999| 459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 +|MW|MW ddddd|0~~99999|((( 461 +MW0=MB(0~~1) 462 + 463 +MW2=MB(2~~3) 464 + 465 +Address value is a multiple of 2 434 434 ))) 467 +|MD|MD ddddd|0~~99999|((( 468 +MD0=MB(0~~3) 435 435 470 +MD4=MB(4~~7) 471 + 472 +Address value is a multiple of 4 473 +))) 474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 +nn: block number; 476 + 477 +dddd: address 478 +))) 479 +|DBxDBW|DBxDBW nndddd|0~~99999999 480 +|DBxDBD|DBxDBD nndddd|0~~99999999 481 + 482 +**3)Configure the communication protocol** 483 + 484 +[[image:image-20220824161345-1.png]] 485 + 486 +**Cable Wiring** 487 + 488 +[[image:image-20220824161450-2.png]] 489 +))) 490 +))) 491 + 436 436 == **S7-1200 Ethernet Protocol** == 437 437 438 438 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 439 439 496 +== ** S7-XXX Ethernet** == 497 + 498 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 + 500 +**HMI Setting** 501 + 502 +|=**Items**|=**Settings**|=**Note** 503 +|Protocol|Siemens S7-XXX| 504 +|Connection|Ethernet| 505 +|Port No.|102| 506 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 +|HMI No.|Rack (Default as 0)| 508 + 509 +Slot from TIA Portal is equal to Device No. of PIStudio 510 + 511 +Rack from TIA Portal is equal to HMI No. of PIStudio 512 + 513 +(% style="text-align:center" %) 514 +[[image:S7-XXXCommunication Settings.png]] 515 + 516 +(% style="text-align:center" %) 517 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 518 + 519 +**Address List** 520 + 521 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 522 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 523 +d:0~-~-9999 524 + 525 +o:0-7 526 +)))| 527 +|Q|Q|Q d.o|((( 528 +d:0~-~-9999 529 + 530 +o:0-7 531 +)))| 532 +|M|M|M d.o|((( 533 +d:0~-~-9999 534 + 535 +o:0-7 536 +)))| 537 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 538 +nn:0-9999, 539 + 540 +dddd:0-9999, 541 + 542 +o:0-7 543 +)))|((( 544 +nn:DB No. 545 + 546 +dddd:address value 547 + 548 +o: digit address 549 +))) 550 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 551 +|M|MW|MW d|d:0-99999|((( 552 +MW0=MB(0~~1) 553 + 554 +MW2=MB(2~~3) 555 + 556 +Address value is a multiple of 2 557 +))) 558 +|M|MD|MD d|d:0-99999|((( 559 +MD0=MB(0~~3) 560 + 561 +MD4=MB(4~~7) 562 + 563 +Address value is a multiple of 4 564 +))) 565 +|I|IW|IW d|d:0-99999| 566 +|Q|QW|QW d|d:0-99999| 567 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 568 +nn:0-9999 569 + 570 +dddd:0-9999 571 +)))|((( 572 +nn:DB No. 573 + 574 +dddd:address value 575 +))) 576 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 577 +nn:0-9999 578 + 579 +dddd:0-9999 580 +)))|((( 581 +nn:DB No. 582 + 583 +dddd:address value 584 + 585 +Address value is a multiple of 2 586 +))) 587 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 588 +nn:0-9999 589 + 590 +dddd:0-9999 591 +)))|((( 592 +nn:DB No. 593 + 594 +dddd:address value 595 + 596 +Address value is a multiple of 4 597 +))) 598 + 599 +**Communication Settings** 600 + 601 +Enable HMI Ethernet in [Project Settings]; 602 + 603 +(% style="text-align:center" %) 604 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 605 + 606 +Set PLC IP in [Device IP] settings; 607 + 608 +(% style="text-align:center" %) 609 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 610 + 611 +**✎Note:** 612 + 613 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 614 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 615 + 616 +**Cable Wiring** 617 + 618 +{{id name="OLE_LINK8"/}} 619 + 620 + 440 440 = **Mitsubishi PLC** = 441 441 442 442 == **Mitsubishi FX Series Protocol** ==
- image-20220824152217-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.6 KB - Content
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.8 KB - Content
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content