... ... @@ -108,15 +108,18 @@
108 108  
109 109  **1)Hardware wiring diagram**
110 110  
111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 +
111 111  [[image:image-20220824142546-2.png]]
112 112  
113 113  [[image:image-20220824142643-3.png]]
114 114  
115 -The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
117 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
116 116  
119 +
117 117  == **LX5V-N Ethernet protocol** ==
118 118  
119 -This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
122 +This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
120 120  
121 121  **Software configuration of PLC**
122 122  
... ... @@ -128,7 +128,7 @@
128 128  
129 129  Click New Project and select the PLC model.
130 130  
131 -[[image:image-20220824143613-1.png]]
134 +[[image:image-20220822172623-2.png]]
132 132  
133 133  **3)Set Ethernet port parameters**
134 134  
... ... @@ -140,38 +140,53 @@
140 140  
141 141  subnet mask:255.255.255.0
142 142  
143 -[[image:image-20220824143744-2.png]]
146 +[[image:image-20220811140530-2.png]]
144 144  
145 145  **4)Registers list**
146 146  
147 -[[image:image-20220822172730-4.png]]
150 +[[image:image-20220811102219-3.png]]
148 148  
149 -(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
152 +**HMI software configuration**
150 150  
151 -**1)V-BOX programming software**
154 +**1)HMI programming software**
152 152  
153 - [[image:image-20220824104124-1.png]]
156 + [[image:image-20220810171237-4.png]]
154 154  
155 -**2)V-NET add device**
158 +**2)New HMI project**
156 156  
157 -Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
160 +Click New Project and select the HMI model.
158 158  
159 -[[image:image-20220824104909-2.png]]
162 +[[image:image-20220810172010-5.png]]
160 160  
161 161  **3)Set communication port parameters**
162 162  
163 -Click Communication to configure the LX5V plc protocol and IP address.
166 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
164 164  
165 -[[image:image-20220824144619-1.png]]
168 +HMI IP address:192.168.39.201
166 166  
170 +default gateway:192.168.39.1
171 +
172 +subnet mask:255.255.255.0
173 +
174 +[[image:image-20220811170753-2.png]]
175 +
176 +Next, click Communication Settings to configure the IP of the HMI communication object.
177 +
178 +[[image:image-20220811163047-1.png]]
179 +
167 167  **hardware connection**
168 168  
169 169  **1)Hardware wiring diagram**
170 170  
171 -[[image:image-20220824151127-2.png]]
184 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
172 172  
173 -The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
186 +[[image:image-20220811170248-1.png]]
174 174  
188 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
189 +
190 +(% style="text-align:center" %)
191 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
192 +
175 175  = **Rockwell PLC** =
176 176  
177 177  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
image-20220824143613-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -85.5 KB
Content